Ion-exchange voltammetry as a solid-phase microextraction analytical method: Factors influencing the mass transfer to perfluorosulfonated ionomer film-coated electrodes and some of their consequences on the current responses

被引:9
作者
Bagel, O [1 ]
Degrand, C [1 ]
Limoges, B [1 ]
机构
[1] Univ Clermont Ferrand 2, Equipe Electrosynthese & Electroanal Bioorgan, UMR 6504, CNRS, F-63177 Aubiere, France
关键词
D O I
10.1021/ac9812025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple theoretical model of mass transfer kinetics at an electrode coated with an ion-exchange film polymer is proposed. The model takes into account the analyte depletion in solution and gives the relationship between the ion-exchange voltammetric (IEV) peak current and the initial analyte concentration in the sample matrix. The verification of the model is investigated at disposable Nafion film-coated screen-printed electrodes, using the redox cationic (ferrocenylmethyl)trimethylammonium salt. It is shown that the theoretical model and the experimental data fit satisfactorily insofar as the variation of the extraction and apparent diffusion coefficients of the salt with the film thickness are taken into account. Indeed, the film thickness plays a crucial role for the optimization of the IEV sensitivity, because the physicochemical properties of the recast Nafion polymer are dependent on the amount per unit area of Nafion deposited on the electrode surface.
引用
收藏
页码:3192 / 3199
页数:8
相关论文
共 34 条
[11]   SENSORS FROM POLYMER MODIFIED ELECTRODES [J].
ESPENSCHEID, MW ;
GHATAKROY, AR ;
MOORE, RB ;
PENNER, RM ;
SZENTIRMAY, MN ;
MARTIN, CR .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1051-1070
[12]   SURFACE-DIFFUSION IN MICROSTRUCTURED, ION-EXCHANGE MATRICES - NAFION/NEUTRON TRACK-ETCHED POLYCARBONATE MEMBRANE COMPOSITES [J].
FANG, Y ;
LEDDY, J .
JOURNAL OF PHYSICAL CHEMISTRY, 1995, 99 (16) :6064-6073
[13]   ION-TRANSPORT AND CLUSTERING IN NAFION PERFLUORINATED MEMBRANES [J].
HSU, WY ;
GIERKE, TD .
JOURNAL OF MEMBRANE SCIENCE, 1983, 13 (03) :307-326
[14]   HOMOGENEOUS ELECTROCHEMICAL IMMUNOASSAY USING A PERFLUOROSULFONATED IONOMER-MODIFIED ELECTRODE AS DETECTOR FOR A CATIONIC-LABELED HAPTEN [J].
LIMOGES, B ;
DEGRAND, C ;
BROSSIER, P ;
BLANKESPOOR, RL .
ANALYTICAL CHEMISTRY, 1993, 65 (08) :1054-1060
[15]   Ferrocenylethyl phosphate: An improved substrate for the detection of alkaline phosphatase by cathodic stripping ion-exchange voltammetry. Application to the electrochemical enzyme affinity assay of avidin [J].
Limoges, B ;
Degrand, C .
ANALYTICAL CHEMISTRY, 1996, 68 (23) :4141-4148
[16]   Redox cationic or procationic labeled drugs detected at a perfluorosulfonated ionomer film-coated electrode [J].
Limoges, B ;
Degrand, C ;
Brossier, P .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 402 (1-2) :175-187
[17]   DYNAMICS OF ORGANIC-COMPOUND EXTRACTION FROM WATER USING LIQUID-COATED FUSED-SILICA FIBERS [J].
LOUCH, D ;
MOTLAGH, S ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1992, 64 (10) :1187-1199
[18]   POLYMER-FILMS ON ELECTRODES .9. ELECTRON AND MASS-TRANSFER IN NAFION FILMS CONTAINING RU(BPY)32+ [J].
MARTIN, CR ;
RUBINSTEIN, I ;
BARD, AJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1982, 104 (18) :4817-4824
[19]   EFFECT OF HYDROPHOBIC INTERACTIONS ON THE RATES OF IONIC-DIFFUSION IN NAFION FILMS AT ELECTRODE SURFACES [J].
MARTIN, CR ;
DOLLARD, KA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1983, 159 (01) :127-135
[20]   ELECTRODE-KINETICS OF METAL-COMPLEXES CONFINED IN PERFLUORO POLYCARBOXYLATE AND POLYSULFONATE COATINGS ON GRAPHITE-ELECTRODES [J].
OYAMA, N ;
OHSAKA, T ;
USHIROGOUCHI, T ;
SANPEI, S ;
NAKAMURA, S .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1988, 61 (09) :3103-3114