Longitudinal stent deformation: quantitative coronary angiographic analysis from the PERSEUS and PLATINUM randomised controlled clinical trials

被引:28
作者
Kereiakes, Dean J. [1 ]
Popma, Jeffrey J. [2 ,3 ,4 ]
Cannon, Louis A. [5 ]
Kandzari, David E. [6 ]
Kimmelstiel, Carey D. [7 ]
Meredith, Ian T. [8 ,9 ]
Teirstein, Paul S. [10 ]
Verheye, Stefan [11 ]
Allocco, Dominic J. [12 ]
Dawkins, Keith D. [12 ]
Stone, Gregg W. [13 ,14 ]
机构
[1] Christ Hosp, Christ Hosp Heart & Vasc Ctr, Lindner Ctr Res & Educ, Cincinnati, OH 45219 USA
[2] Beth Israel Deaconess Med Ctr, Div Cardiovasc, Dept Internal Med, Boston, MA 02215 USA
[3] Beth Israel Deaconess Med Ctr, Cardiothorac Div, Dept Internal Med, Boston, MA 02215 USA
[4] Harvard Univ, Sch Med, Boston, MA USA
[5] No Michigan Reg Hosp, Cardiac & Vasc Res Ctr No Michigan, Petoskey, MI USA
[6] Piedmont Heart Inst, Dept Intervent Cardiol & Intervent Cardiol Res, Atlanta, GA USA
[7] Tufts Med Ctr, Cardiac Catheterizat Lab, Div Cardiol, Boston, MA USA
[8] Monash Univ, Melbourne, Vic 3004, Australia
[9] Monash Med Ctr, Melbourne, Vic, Australia
[10] Scripps Clin, La Jolla, CA USA
[11] Ziekenhuis Netwerk Antwerpen, Antwerp Cardiovasc Inst Middelheim, Antwerp, Belgium
[12] Boston Sci Corp, Natick, MA USA
[13] Columbia Univ, Med Ctr, New York, NY USA
[14] Cardiovasc Res Fdn, New York, NY USA
关键词
stent deformation; drug-eluting stent; element stent; PACLITAXEL-ELUTING STENT; TAXUS LIBERTE STENT; BARE METAL STENT; ARTERY-DISEASE; SMALL VESSELS; INTRAVASCULAR ULTRASOUND; SPIRIT III; ION STENT; RESTENOSIS; DESIGN;
D O I
10.4244/EIJV8I2A32
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Recent reports have suggested susceptibility of novel thin-strut coronary stents to incur longitudinal stent deformation during or following deployment. This analysis assesses the incidence of longitudinal stent deformation in three stent platforms. Methods and results: Quantitative angiographic analysis (QCA) of 2,403 stents from the PERSEUS Workhorse (WH) and PLATINUM-WH trials was performed by an independent core laboratory. The distribution of QCA measured: nominal stent length ratios was compared between platforms to evaluate longitudinal stent deformation. Stent length ratio averaged 0.95 +/- 0.07 in the TAXUS Express arm and 0.94 +/- 0.06 in the ION (TAXUS Element) arm of the PERSEUS-WH trial (p=0.16). In the PLATINUM-WH trial, the mean ratio in the PROMUS cohort was slightly smaller (0.92 +/- 0.09) than PROMUS Element (0.94 +/- 0.08; p=0.004). Manual, blinded re-examination by the core laboratory of the angiograms corresponding to the 20 lowest and highest ratios in each trial did not identify any cases of stent deformation. Conclusions: Systematic analysis by an independent angiographic core laboratory of 2,403 stents implanted in patients enrolled in two large multicentre randomised trials demonstrated no stent deformation or meaningful differences in stent length ratios between ION and TAXUS Express or between PROMUS Element and PROMUS in the patient populations studied using the methodology employed.
引用
收藏
页码:187 / 195
页数:9
相关论文
共 39 条
[1]   A prospective evaluation of the safety and efficacy of the TAXUS Element paclitaxel-eluting coronary stent system for the treatment of de novo coronary artery lesions: Design and statistical methods of the PERSEUS clinical program [J].
Allocco, Dominic J. ;
Cannon, Louis A. ;
Britt, Amy ;
Heil, John E. ;
Nersesov, Andrey ;
Wehrenberg, Scott ;
Dawkins, Keith D. ;
Kereiakes, Dean J. .
TRIALS, 2010, 11
[2]   An Everolimus-Eluting Stent Versus a Paclitaxel-Eluting Stent in Small Vessel Coronary Artery Disease: A Pooled Analysis from the SPIRIT II and SPIRIT III Trials [J].
Bartorelli, Antonio L. ;
Serruys, Patrick W. ;
Miquel-Hebert, Karine ;
Yu, Shui ;
Pierson, Wes ;
Stone, Gregg W. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (01) :60-66
[3]   Medical progress: Advances in coronary angioplasty [J].
Bittl, JA .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 335 (17) :1290-1302
[4]  
Cannon LA, 2011, J AM COLL CARDIOL, V58, pB70
[5]   A prospective evaluation of the safety and efficacy of TAXUS Element paclitaxel-eluting coronary stent implantation for the treatment of de novo coronary artery lesions in small vessels: the PERSEUS Small Vessel trial [J].
Cannon, Louis A. ;
Kereiakes, Dean J. ;
Mann, Tift ;
Popma, Jeffrey J. ;
Mooney, Michael R. ;
Mishkel, Gregory J. ;
Lee, Tommy C. ;
Wilson, B. Hadley ;
Stuckey, Thomas D. ;
Orlow, Steven ;
McGarry, Thomas ;
Ring, Michael E. ;
Kellett, Mirle A. ;
Underwood, Paul ;
Dawkins, Keith D. .
EUROINTERVENTION, 2011, 6 (08) :920-927
[6]  
Finet G, 2011, EUROINTERVENTION
[7]   Does stent design influence restenosis? [J].
Gunn, J ;
Cumberland, D .
EUROPEAN HEART JOURNAL, 1999, 20 (14) :1009-1013
[8]  
Gurbel Paul A, 2002, J Invasive Cardiol, V14, P584
[9]   Longitudinal compression: a "new" complication with modern coronary stent platforms - time to think beyond deliverability? [J].
Hanratty, Colm G. ;
Walsh, Simon J. .
EUROINTERVENTION, 2011, 7 (07) :872-877
[10]   Relation of stent design and stent surface material to subsequent in-stent intimal hyperplasia in coronary arteries determined by intravascular ultrasound [J].
Hoffmann, R ;
Mintz, GS ;
Haager, PK ;
Bozoglu, T ;
Grube, E ;
Gross, M ;
Beythien, C ;
Mudra, H ;
vom Dahl, J ;
Hanrath, P .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (12) :1360-1364