New developments in thermospray sample introduction for atomic spectrometry

被引:37
作者
Conver, TS [1 ]
Yang, JF [1 ]
Koropchak, JA [1 ]
机构
[1] SO ILLINOIS UNIV,DEPT CHEM & BIOCHEM,CARBONDALE,IL 62901
关键词
thermospray sample introduction; aerosol techniques; aerosol size distributions; inductively coupled plasma-atomic emission spectrometry; inductively coupled plasma-mass spectrometry; flame atomic absorption; limits of detection; matrix effects; environmental analysis; flow injection analysis; metal speciation;
D O I
10.1016/S0584-8547(97)00004-9
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The status of thermospray sample introduction for analytical atomic spectrometry was last reviewed in 1992. In this review, we summarize developments in this field since that time, including investigations of aerosol generation processes, noise diagnosis and control with inductively coupled plasma-atomic emission or mass spectrometry (ICP-AES/MS), high Bow thermospray, the use of dual-stage desolvation systems based on membrane dryers, and the utilization of thermospray with axially viewed ICP-AES. Since a major advantage of methods based on thermospray is improved limits of detection, the emphasis for applications of thermospray with ICP spectrometries remains focused on environmental sample types, particularly with ICP-MS. Relatedly, the use of thermospray as a means for the direct speciation of Se is also under development. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:1087 / 1104
页数:18
相关论文
共 66 条
[41]   ARGON INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY WITH THERMOSPRAY, ULTRASONIC, AND PNEUMATIC NEBULIZATION [J].
MONTASER, A ;
TAN, H ;
ISHII, I ;
NAM, SH ;
CAI, MX .
ANALYTICAL CHEMISTRY, 1991, 63 (22) :2660-2665
[42]  
Montaser A., 1992, INDUCTIVELY COUPLED, V2nd
[43]   Behaviour of the thermospray nebulizer as a system for the introduction of organic solutions in flame atomic absorption spectrometry [J].
Mora, J ;
Canals, A ;
Hernandis, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (12) :1535-1549
[44]   COMPARISON OF JARRELL-ASH, PERKIN-ELMER, AND MODIFIED PERKIN-ELMER NEBULIZERS FOR INDUCTIVELY COUPLED PLASMA ANALYSIS [J].
NIXON, DE ;
SMITH, GA .
ANALYTICAL CHEMISTRY, 1986, 58 (13) :2886-2888
[45]   COMPARISON OF 2 MEINHARD NEBULIZERS OPERATING AT THE SAME ARGON FLOW BUT DIFFERENT PRESSURES [J].
NIXON, DE .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (03) :447-459
[46]   FIXED CROSS-FLOW NEBULIZER FOR USE WITH INDUCTIVELY COUPLED PLASMAS AND FLAMES [J].
NOVAK, JW ;
LILLIE, DE ;
BOORN, AW ;
BROWNER, RF .
ANALYTICAL CHEMISTRY, 1980, 52 (03) :576-579
[47]   INCOMPLETELY DESOLVATED DROPLETS IN ARGON INDUCTIVELY COUPLED PLASMAS - THEIR NUMBER, ORIGINAL SIZE AND EFFECT ON EMISSION INTENSITIES [J].
OLESIK, JW ;
FISTER, JC .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (6-7) :851-868
[48]   Evaluation of a flow injection system combined with an inductively coupled plasma mass spectrometer with thermospray nebulization for the determination of trace levels of platinum [J].
Parent, M ;
Vanhoe, H ;
Moens, L ;
Dams, R .
ANALYTICA CHIMICA ACTA, 1996, 320 (01) :1-10
[49]  
Parent M, 1996, FRESEN J ANAL CHEM, V354, P664
[50]   ANALYTICAL PERFORMANCE OF A THERMOSPRAY SAMPLE INTRODUCTION SYSTEM FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
PENG, RZ ;
TIGGELMAN, JJ ;
DELOOSVOLLEBREGT, MTC .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (1-2) :189-199