Enhanced sensitivity for Cu(II) by a salicylidine-functionalized polysiloxane carbon paste electrode

被引:34
作者
Abu-Shawish, Hazem M. [1 ]
Saadeh, Salman M. [2 ]
Hussien, Ahmad R. [1 ]
机构
[1] Al Aqsa Univ, Fac Sci, Gaza, Israel
[2] Islam Univ Gaza, Coll Sci, Dept Chem, Gaza, Israel
关键词
carbon paste electrodes; potentiometry; sol-gel; copper(II) selective; functionalized polysiloxane;
D O I
10.1016/j.talanta.2008.04.063
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new approach for decreasing the detection limit fora copper(II) ion-selective electrode (ISE) is presented, The ISE is designed using salicylidine-functionalized polysiloxane in carbon paste. This work describes the attempts to develop the electrode and measurements of its characteristics. The new type of renewable three-dimensional chemically modified electrode could be used in a pH range of 2.3-5.4, and its detection limit is 2.7 x 10(-8) mol L-1 (1.2 mu g L-1). This sensor exhibits a good Nernstian slope of 29.4 +/- 0.5 mV/decade in a wide linear concentration range of 2.3 x 10(-7) to 1.0 x 10(-3) mol L-1 of Cu(II). It has a short response time (similar to 8 s) and noticeably high selectivity over other Cu(II) selective electrodes. Finally, it was satisfactorily used as an indicator electrode in complexometric titration with EDTA and determination of copper(II) in miscellaneous samples such as urine and various water samples. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:941 / 948
页数:8
相关论文
共 37 条
[1]   Chemically modified carbon paste electrode for determination of copper(II) by potentiometric method [J].
Abbaspour, A ;
Moosavi, SMM .
TALANTA, 2002, 56 (01) :91-96
[2]  
Abu-Shawish HM, 2007, CAN J ANAL SCI SPECT, V52, P225
[3]   Potentiometric response of modified carbon paste electrode based on mixed ion-exchangers [J].
Abu-Shawish, Hazem M. .
ELECTROANALYSIS, 2008, 20 (05) :491-497
[4]   A new chemically modified carbon paste electrode for determination of copper based on N,N'-disalicylidenehexameythylenediaminate copper(II) complex [J].
Abu-Shawish, Hazem M. ;
Saadeh, Salman M. .
SENSOR LETTERS, 2007, 5 (3-4) :565-571
[5]   Ion-selective electrode for aluminum determination in pharmaceutical substances, tea leaves and water samples [J].
Arvand, M. ;
Asadollahzadeh, S. A. .
TALANTA, 2008, 75 (04) :1046-1054
[6]  
Ashgar N.M., 2006, ALAQSA U J, V10, P153
[7]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[8]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[9]   Analytical applications of organically modified silicates [J].
Collinson, MM .
MIKROCHIMICA ACTA, 1998, 129 (3-4) :149-165
[10]  
Collinson MM, 2002, TRAC-TREND ANAL CHEM, V21, P30