Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema

被引:141
作者
Forooghian, Farzin [2 ]
Cukras, Catherine [2 ]
Meyerle, Catherine B. [2 ]
Chew, Emily Y. [2 ]
Wong, Wai T. [1 ]
机构
[1] NEI, Off Sci Director, NIH, Bethesda, MD 20892 USA
[2] NEI, Div Epidemiol & Clin Res, NIH, Bethesda, MD 20892 USA
关键词
D O I
10.1167/iovs.08-2113
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To evaluate macular thickness and volume measurements and their intrasession repeatability in two optical coherence tomography (OCT) systems: the Stratus OCT, a time domain system, and the Cirrus HD-OCT, a spectral domain system (both by Carl Zeiss Meditec, Inc., Dublin, CA), in the context of diabetic macular edema (DME). METHODS. Thirty-three eyes of 33 diabetic patients with clinically significant macular edema (CSME) were scanned in a single session by a single operator on both OCT systems. Macular thickness measurements of nine standard macular sub-fields and total macular volume were obtained and analyzed. Bland-Altman plots were constructed to assess agreement in macular measurements. Intraclass correlation coefficients (ICCs), coefficients of repeatability (CRW), and coefficients of variation (CVW) were used to assess intrasession repeatability. RESULTS. Macular thickness in nine retinal subfields and macular volume were significantly higher in the Cirrus HD-OCT system compared with the Stratus OCT system. Subfield thickness and total volume measurements, respectively, were 30 to 55 mu m and 3.2 mm(3) greater for the Cirrus HD-OCT system compared with the Stratus OCT system. Both Stratus OCT and Cirrus HD-OCT systems demonstrated high intrasession repeatability, with overlapping ranges for CRW, CVW, and ICC. Repeatability measures (CRW and CVW) differed significantly between systems in only one of nine subfields (outer temporal subfield). CONCLUSIONS. Absolute measures of macular thickness and volume in patients with DME differed significantly in magnitude between the Stratus OCT and Cirrus HD-OCT systems. However, both OCT systems demonstrated high intrasessional repeatability. Although the two systems may not be used interchangeably, they appear equally reliable in generating macular measurements for clinical practice and research.
引用
收藏
页码:4290 / 4296
页数:7
相关论文
共 17 条
[1]   Three-dimensional imaging of pigment epithelial detachment in age-related macular degeneration using optical coherence tomography, retinal thickness analysis and topographic angiography [J].
Ahlers, Christian ;
Michels, Stephan ;
Beckendorf, Arne ;
Birngruber, Reginald ;
Schmidt-Erfurth, Ursula .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 244 (10) :1233-1239
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Results and repeatability of retinal thickness measurements from certification submissions [J].
Danis, Ronald P. ;
Fisher, Marian R. ;
Lambert, Ericka ;
Goulding, Anne ;
Wu, Deborah ;
Lee, Li-Yin .
ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (01) :45-50
[4]  
Davis MD, 2005, ARCH OPHTHALMOL-CHIC, V123, P1484
[5]   Three-dimensional imaging of macular holes with high-speed optical coherence tomography [J].
Hangai, Masanori ;
Jima, Yumiko ;
Gotoh, Norimoto ;
Inoue, Ryo ;
Yasuno, Yoshiaki ;
Makita, Shuichi ;
Yarnanari, Masahiro ;
Yatagai, Toyohiko ;
Kita, Mihori ;
Yoshimura, Nagahisa .
OPHTHALMOLOGY, 2007, 114 (04) :763-773
[6]   Diagnosis of macular pseudoholes and lamellar macular holes by optical coherence tomography [J].
Haouchine, B ;
Massin, P ;
Tadayoni, R ;
Erginay, A ;
Gaudric, A .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 138 (05) :732-739
[7]   THE DEVELOPMENT OF PARAFOVEAL AND MID-PERIPHERAL HUMAN RETINA [J].
HENDRICKSON, A ;
DRUCKER, D .
BEHAVIOURAL BRAIN RESEARCH, 1992, 49 (01) :21-31
[8]   Optical coherence tomography to detect and manage retinal disease and glaucoma [J].
Jaffe, GJ ;
Caprioli, J .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (01) :156-169
[9]   Reproducibility of macular thickness and volume using zeiss optical coherence tomography in patients with diabetic macular edema [J].
Krzystolik, Magdalena G. ;
Strauber, Samara F. ;
Ai-ello, Lloyd Paul ;
Beek, Roy W. ;
Berger, Brian B. ;
Bressler, Neil M. ;
Browning, David J. ;
Chambers, Robert B. ;
Danis, Ronald P. ;
Davis, Matthew D. ;
Glassman, Adam R. ;
Gonzalez, Victor H. ;
Greenberg, Paul B. ;
Gross, Jeffrey G. ;
Kim, Judy E. ;
Kollman, Craig .
OPHTHALMOLOGY, 2007, 114 (08) :1520-1525
[10]   Comparative study of central corneal thickness measurement with slit-lamp optical coherence tomography and visante optical coherence tomography [J].
Li, Haitao ;
Leung, Christopher Kai Shun ;
Wong, Lee ;
Cheung, Carol Yim Lui ;
Pang, Chi Pui ;
Weinreb, Robert Neal ;
Lam, Dennis Shun Chiu .