Technetium 99m-labeled tetrofosmin myocardial tomography in patients with coronary artery disease: Comparison between adenosine and dynamic exercise stress testing

被引:29
作者
Cuocolo, A
Nicolai, E
Soricelli, A
Pace, L
Nappi, A
Sullo, P
Cardei, S
Argenziano, L
Ell, PJ
Salvatore, M
机构
[1] UNIV NAPLES FEDERICO II, CATTEDRA MED NUCL, CNR, CTR MED NUCL, NAPLES, ITALY
[2] UNIV NAPLES FEDERICO II, CLIN MED 1, NAPLES, ITALY
[3] UCL, INST NUCL MED, LONDON, ENGLAND
关键词
myocardial perfusion; adenosine; technetium 99m-labeled tetrofosmin;
D O I
10.1016/S1071-3581(96)90033-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Pharmacologic coronary vasodilation with adenosine, combined with myocardial scintigraphy, is a useful test for the diagnosis of coronary artery disease (CAD) in patients unable to exercise. It has been demonstrated recently that exercise Tc-99m-labeled tetrofosmin cardiac imaging can be used for the detection of CAD. However, no data are available comparing Tc-99m-labeled tetrofosmin adenosine and exercise tests in the same patients. Methods and Results. The results of adenosine and exercise Tc-99m-labeled tetrofosmin myocardial tomography were compared in 41 patients (37 men and four women; mean age 53 +/- 8 years) with suspected or known CAD who underwent coronary angiography, All patients were submitted, on separate days, to three injections of Tc-99m-labeled tetrofosmin (740 MBq intravenously): one at rest, one during bicycle exercise, and one during adenosine infusion (140 mu g/kg/min for 6 minutes with injection of Tc-99m-labeled tetrofosmin at 4 minutes). A total of 902 myocardial segments were analyzed quantitatively. One patient had normal coronary vessels, 19 patients had single-vessel CAD, 12 patients had two-vessel CAD, and nine patients had three-vessel CAD (>50% coronary stenosis) on coronary angiography. Adenosine induced a significant increase in heart rate (88 +/- 16 beats/min at peak vs 72 +/- 11 beats/min at rest; p < 0.01). Systolic and diastolic blood pressure was not significantly different after adenosine infusion compared with rest, Double product was 22931 +/- 7039 at peak exercise and 11229 +/- 3413 after adenosine (p < 0.01). Agreement on the presence of abnormal single-photon emission computed tomography by adenosine and exercise was 100% by quantitative analysis, In all segments a significant relationship between exercise and adenosine Tc-99m-99m-labeled tetrofosmin uptake was observed (r = 0.90; p < 0.001). Segmental agreement for regional Tc-99m-labeled tetrofosmin uptake score between exercise and adenosine was observed in 737 (82%) of the 902 segments (kappa value of 0.66). Concordance between the two studies for identification of perfusion status was observed in 809 (90%) of the segments (kappa value of 0.80). Sensitivity and specificity for detection of stenosed vessels were not different for dynamic exercise stress testing and adenosine Tc-99m-labeled tetrofosmin cardiac tomography. Conclusions. Despite different hemodynamic effects, adenosine and dynamic exercise Tc-99m-labeled tetrofosmin single-photon emission computed tomographic imaging provides similar information in the diagnosis and localization of CAD.
引用
收藏
页码:194 / 203
页数:10
相关论文
共 27 条
  • [21] RIGO P, 1994, J NUCL MED, V35, P587
  • [22] EFFECT OF ISCHEMIA AND POSTISCHEMIC DYSFUNCTION ON MYOCARDIAL UPTAKE OF TECHNETIUM-99M-LABELED METHOXYISOBUTYL ISONITRILE AND TL-201
    SINUSAS, AJ
    WATSON, DD
    CANNON, JM
    BELLER, GA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (07) : 1785 - 1793
  • [23] SINUSAS AJ, 1994, J NUCL MED, V35, P664
  • [24] COMPARISON OF MYOCARDIAL PERFUSION IMAGING WITH TC-99M TETROFOSMIN VERSUS TL-201 IN CORONARY-ARTERY DISEASE
    SRIDHARA, BS
    BRAAT, S
    RIGO, P
    ITTI, R
    CLOAD, P
    LAHIRI, A
    RAVAL, U
    FOULON, J
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (14) : 1015 - 1019
  • [25] TAMAKI N, 1994, J NUCL MED, V35, P594
  • [26] TARTAGNI F, 1991, J NUCL MED, V32, P369
  • [27] DIAGNOSIS OF CORONARY-ARTERY DISEASE BY CONTROLLED CORONARY VASODILATION WITH ADENOSINE AND TL-201 SCINTIGRAPHY IN PATIENTS UNABLE TO EXERCISE
    VERANI, MS
    MAHMARIAN, JJ
    HIXSON, JB
    BOYCE, TM
    STAUDACHER, RA
    [J]. CIRCULATION, 1990, 82 (01) : 80 - 87