Progress in developing focal-plane-multiplexer readout for large CdZnTe arrays for nuclear medicine applications

被引:26
作者
Barber, HB
Marks, DG
Apotovsky, BA
Augustine, FL
Barrett, HH
Butler, JF
Dereniak, EL
Doty, FP
Eskin, JD
Hamilton, WJ
Matherson, KJ
Venzon, JE
Woolfenden, JM
Young, ET
机构
[1] UNIV ARIZONA,CTR OPT SCI,TUCSON,AZ 85721
[2] DIGIRAD,SAN DIEGO,CA 92121
[3] AUGUSTINE ENGN,ENCINITAS,CA 92024
[4] SANTA BARBARA RES CTR,GOLETA,CA 93117
[5] UNIV ARIZONA,STEWARD OBSERV,TUCSON,AZ 85721
基金
美国国家卫生研究院;
关键词
D O I
10.1016/S0168-9002(96)00472-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report on the construction and initial testing of a 48 x 48 CdZnTe array with 125 mu m pixel spacing and multiplexer readout. Large portions of the array function well but there was a loss of pixels near one corner of the array due to non-interconnecting indium bumps. This problem is readily correctable. Excellent single-pixel spectra were obtained with a (TC)-T-99m source using an adjustment technique that accounts for energy deposited in neighboring pixels. A point-spread function (PSF) taken at 140 keV yielded a spatial resolution of 230 mu m, much better than required for nuclear medicine applications. No problems were found that are not readily correctable or of much less significance for CdZnTe arrays having larger pixel spacing. We are now constructing 64 x 64 CdZnTe arrays with 380 mu m pixel spacing for use in an ultra-high resolution brain SPECT imaging system.
引用
收藏
页码:262 / 265
页数:4
相关论文
共 14 条
[1]  
AUGUSTEINE FL, 1994, NUCL INSTRUM METH A, V353, P301
[2]   A GAMMA-RAY IMAGER WITH MULTIPLEXER READ-OUT FOR USE IN ULTRA-HIGH-RESOLUTION BRAIN SPECT [J].
BARBER, HB ;
BARRETT, HH ;
DERENIAK, EL ;
HARTSOUGH, NE ;
PERRY, DL ;
ROBERTS, PCT ;
ROGULSKI, MM ;
WOOLFENDEN, JM ;
YOUNG, ET .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :1140-1144
[3]   SEMICONDUCTOR ARRAYS WITH MULTIPLEXER READOUT FOR GAMMA-RAY IMAGING - RESULTS FOR A 48X48 GE ARRAY [J].
BARBER, HB ;
AUGUSTINE, FL ;
BARRETT, HH ;
DERENIAK, EL ;
MATHERSON, KL ;
MEYERS, TJ ;
PERRY, DL ;
VENZON, JE ;
WOOLFENDEN, JM ;
YOUNG, ET .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :361-365
[4]  
BARBER HB, 1993, PHYS MEDICA, V9, P135
[5]  
BARBER HB, 1994, 1993 IEEE NUCL SCI S, V2, P1381
[6]   CHARGE-TRANSPORT IN ARRAYS OF SEMICONDUCTOR GAMMA-RAY DETECTORS [J].
BARRETT, HH ;
ESKIN, JD ;
BARBER, HB .
PHYSICAL REVIEW LETTERS, 1995, 75 (01) :156-159
[7]   CD1-XZNXTE4 GAMMA-RAY DETECTORS [J].
BUTLER, JF ;
LINGREN, CL ;
DOTY, FP .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :605-609
[8]  
CUZIN M, 1994, P SOC PHOTO-OPT INS, V2278, P21, DOI 10.1117/12.180024
[9]   PIXELLATED CDZNTE DETECTOR ARRAYS [J].
DOTY, FP ;
BARBER, HB ;
AUGUSTINE, FL ;
BUTLER, JF ;
APOTOVSKY, BA ;
YOUNG, ET ;
HAMILTON, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :356-360