Fast magnetic resonance imaging of liver

被引:32
作者
Ichikawa, T [1 ]
Araki, T [1 ]
机构
[1] Yamanashi Med Univ, Dept Radiol, Yamanashi 4093821, Japan
关键词
fast magnetic resonance imaging; liver; T2-weighted imaging;
D O I
10.1016/S0720-048X(98)00176-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent magnetic resonance (MR) units with a stronger gradient system have allowed various fast MR imaging techniques to develop. These fast scan techniques have easily realized breath-holding acquisition in the liver and the image quality has been greatly improved without sacrificing spatial resolution. The majority of the fast imaging techniques have been devoted to T2-weighted imaging to obtain useful T2-weighted images in the shortest possible time. Among the fast sequences, fast spin-echo (FSE) sequence is the most promising technique and allows high-quality T2-weighted images with reduced motion artifacts. However, FSE sequences using multiple refocused pulses may essentially realize only poor soft-tissue contrast due to magnetization transfer and T2-filtering effects, and therefore, echo-planar (EP) imaging is expected to provide high image contrast. In addition, single-shot EP imaging allows even diffusion-weighted (DW) and perfusion-weighted (PW) imaging in the liver due to its short scanning time. Recent development of fast gadolinium-enhanced 3D MR angiography has also impacted liver imaging. Combined with such gadolinium-enhanced 3D-MRA sequences and zerofilling image interpolation technique, biphasic gadolinium-enhanced 3D-MRA (whole-liver dynamic MR imaging in the arterial phase and MR portography in the portal phase) can be obtained. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:186 / 210
页数:25
相关论文
共 78 条
[1]  
AMANUMA M, 1995, P SOC MAGN RES 1995, P1473
[2]   BLOOD-FLOW IN THE PORTAL-VEIN - VELOCITY QUANTITATION WITH PHASE-CONTRAST MR ANGIOGRAPHY [J].
APPLEGATE, GR ;
THAETE, FL ;
MEYERS, SP ;
DAVIS, PL ;
TALAGALA, SL ;
RECHT, M ;
WOZNEY, P ;
KANAL, E .
RADIOLOGY, 1993, 187 (01) :253-256
[3]  
BEERS BV, 1990, AJR, V154, P515
[4]   CONTRAST-ENHANCED NMR IMAGING - ANIMAL STUDIES USING GADOLINIUM-DTPA COMPLEX [J].
BRASCH, RC ;
WEINMANN, HJ ;
WESBEY, GE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 142 (03) :625-630
[5]   ECHO-PLANAR IMAGING OF THE LIVER WITH A STANDARD MR-IMAGING SYSTEM [J].
BUTTS, K ;
RIEDERER, SJ ;
EHMAN, RL ;
FELMLEE, JP ;
GRIMM, RC .
RADIOLOGY, 1993, 189 (01) :259-264
[6]   MR-IMAGING OF THE ABDOMEN WITH A PHASED-ARRAY MULTICOIL - PROSPECTIVE CLINICAL-EVALUATION [J].
CAMPEAU, NG ;
JOHNSON, CD ;
FELMLEE, JP ;
RYDBERG, JN ;
BUTTS, RK ;
EHMAN, RL ;
RIEDERER, SJ .
RADIOLOGY, 1995, 195 (03) :769-776
[7]  
COLDBERG MA, 1993, AM J RADIOL, V160, P1011
[8]   Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1996, 201 (03) :705-710
[9]   Dysplastic nodules and hepatocellular carcinoma: Thin-section MR imaging of explanted cirrhotic livers with pathologic correlation [J].
Earls, JP ;
Theise, ND ;
Weinreb, JC ;
DeCorato, DR ;
Krinsky, GA ;
Rofsky, NM ;
Mizrachi, H ;
Teperman, LW .
RADIOLOGY, 1996, 201 (01) :207-214
[10]   MR IMAGING OF SMALL HEPATOCELLULAR-CARCINOMA - EFFECT OF INTRATUMORAL COPPER CONTENT ON SIGNAL INTENSITY [J].
EBARA, M ;
WATANABE, S ;
KITA, K ;
YOSHIKAWA, M ;
SUGIURA, N ;
OHTO, M ;
KONDO, F ;
KONDO, Y .
RADIOLOGY, 1991, 180 (03) :617-621