Chemically induced phosphorescence from manganese(II) during the oxidation of various compounds by manganese(III), (IV) break and (VII) in acidic aqueous solutions

被引:75
作者
Barnett, NW [1 ]
Hindson, BJ
Jones, P
Smith, TA
机构
[1] Deakin Univ, Sch Biol & Chem Sci, Ctr Chiral & Mol Technol, Geelong, Vic 3217, Australia
[2] Univ Plymouth, Dept Environm Sci, Plymouth PL4 8AA, Devon, England
[3] Univ Melbourne, Sch Chem, Parkville, Vic 3010, Australia
关键词
chemiluminescence; phosphorescence; manganese oxidants;
D O I
10.1016/S0003-2670(01)01414-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chemiluminescence was observed during the manganese(III), (IV) and (VII) oxidations of sodium tetrahydroborate, sodium dithionite, sodium sulfite and hydrazine sulfate in acidic aqueous solution. From the corrected chemiluminescence spectra, the wavelengths of maximum emission were 689 +/- 5 and 734 +/- 5 nm when the reactions were performed in sodium hexametaphosphate and sodium dihydrogenorthophosphate/orthophosphoric acid environments, respectively. The corrected phosphorescence spectrum of manganese(II) sulfate in a solution of sodium hexametaphosphate at 77 K exhibited two peaks with maxima at 688 and 730 nm. The chemical and spectroscopic evidence presented strongly supported the postulation that the emission was an example of solution-phase chemically induced phosphorescence of manganese(II) thereby, confirming earlier predictions that the chemiluminescence from acidic potassium permanganate reactions originated from an excited manganese(II) species. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:181 / 188
页数:8
相关论文
共 54 条
[1]   DETERMINATION OF MORPHINE BY FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION [J].
ABBOTT, RW ;
TOWNSHEND, A ;
GILL, R .
ANALYST, 1986, 111 (06) :635-640
[2]   Direct chemiluminescence determination of ascorbic acid using flow injection analysis [J].
Agater, IB ;
Jewsbury, RA .
ANALYTICA CHIMICA ACTA, 1997, 356 (2-3) :289-294
[3]   Determination of carbohydrates by flow injection with direct chemiluminescence detection [J].
Agater, IB ;
Jewsbury, RA ;
Williams, K .
ANALYTICAL COMMUNICATIONS, 1996, 33 (10) :367-369
[4]   DETERMINATION OF MORPHINE IN-PROCESS STREAMS USING FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION [J].
BARNETT, NW ;
ROLFE, DG ;
BOWSER, TA ;
PATON, TW .
ANALYTICA CHIMICA ACTA, 1993, 282 (03) :551-557
[5]   Determination of 5-hydroxytryptamine (serotonin) and related indoles by flow injection analysis with acidic potassium permanganate chemiluminescence detection [J].
Barnett, NW ;
Hindson, BJ ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 1998, 362 (2-3) :131-139
[6]   Determination of ranitidine and salbutamol by flow injection analysis with chemiluminescence detection [J].
Barnett, NW ;
Hindson, BJ ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 1999, 384 (02) :151-158
[7]   Determination of morphine, oripavine and pseudomorphine using capillary electrophoresis with acidic potassium permanganate chemiluminescence detection [J].
Barnett, NW ;
Hindson, BJ ;
Lewis, SW .
ANALYST, 2000, 125 (01) :91-95
[8]   Soluble manganese(IV); a new chemiluminescence reagent [J].
Barnett, NW ;
Hindson, BJ ;
Lewis, SW ;
Jones, P ;
Worsfold, PJ .
ANALYST, 2001, 126 (10) :1636-1639
[9]  
Blasse G., 1994, LUMINESCENT MAT, P52
[10]   Chemiluminescence determination of naltrexone based on potassium permanganate oxidation [J].
Campiglio, A .
ANALYST, 1998, 123 (05) :1053-1056