Pulsed amperometric detection with poly(dimethylsiloxane)-fabricated capillary electrophoresis microchips for the determination of EPA priority pollutants

被引:39
作者
Ding, YS
Garcia, CD [1 ]
机构
[1] Univ Texas, Dept Chem, San Antonio, TX 78249 USA
[2] Peking Univ, Hlth Sci Ctr, Dept Biol Chem, Beijing 100083, Peoples R China
关键词
D O I
10.1039/b509405d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniaturized analytical system for separation and detection of three EPA priority phenolic pollutants, based on a poly(dimethylsiloxane)-fabricated capillary electrophoresis microchip and pulsed amperometric detection is described. The approach offers a rapid (less than 2 min), simultaneous measurement of three phenolic pollutants: phenol, 4,6-dinitro-o-cresol and pentachlorophenol. The highly stable response (RSD = 6.1%) observed for repetitive injections (n > 100) reflects the effectiveness of Au working electrode cleaned by pulsed amperometric detection. The effect of solution conditions, separation potential and detection waveform were optimized for both the separation and detection of phenols. Under the optimum conditions (5.0 mM phosphate buffer pH 5 12.4, detection potential: 0.7 V, separation potential: 1200 V, injection time: 10 s) the baseline separation of the three selected compounds was achieved. Limits of detection of 2.2 mu M (2.8 fmol), 0.9 mu M (1.1 fmol), and 1.3 mu M (1.6 fmol) were achieved for phenol, 4,6-dinitro-o-cresol and pentachlorophenol, respectively. A local city water sample and two over-the-counter sore-throat medicines were analyzed in order to demonstrate the capabilities of the proposed technique to face real applications.
引用
收藏
页码:208 / 214
页数:7
相关论文
共 81 条
[1]  
Babich H, 1981, Regul Toxicol Pharmacol, V1, P90, DOI 10.1016/0273-2300(81)90071-4
[2]   Determination of cannabinoids in hair using high-pH* non-aqueous electrolytes and electrochemical detection - Some aspects of sensitivity and selectivity [J].
Backofen, U ;
Matysik, FM ;
Lunte, CE .
JOURNAL OF CHROMATOGRAPHY A, 2002, 942 (1-2) :259-269
[3]   Measurement of p-nitrophenol in the urine of residents whose homes were contaminated with methyl parathion [J].
Barr, DB ;
Turner, WE ;
DiPietro, E ;
McClure, PC ;
Baker, SE ;
Barr, JR ;
Gehle, K ;
Grissom, RE ;
Bravo, R ;
Driske, WJ ;
Patterson, DG ;
Hill, RH ;
Needham, LL ;
Pirkle, JL ;
Sampson, EJ .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2002, 110 :1085-1091
[4]   Polymer microfluidic devices [J].
Becker, H ;
Locascio, LE .
TALANTA, 2002, 56 (02) :267-287
[5]   SUMMARY REVIEW OF THE HEALTH-EFFECTS ASSOCIATED WITH PHENOL [J].
BRUCE, RM ;
SANTODONATO, J ;
NEAL, MW .
TOXICOLOGY AND INDUSTRIAL HEALTH, 1987, 3 (04) :535-568
[6]   Prediction of the separation of phenols by capillary zone electrophoresis [J].
Canals, I ;
Bosch, E ;
Rosés, M .
ANALYTICA CHIMICA ACTA, 2002, 458 (02) :355-366
[7]   Determination of herbicides, including thermally labile phenylureas, by solid-phase microextraction and gas chromatography-mass spectrometry [J].
Carabias-Martínez, R ;
García-Hermida, C ;
Rodríguez-Gonzalo, E ;
Soriano-Bravo, FE ;
Hernández-Méndez, J .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1002 (1-2) :1-12
[8]   Capillary electrophoresis of neurotransmitters with amperometric detection at melanin-type polymer-modified carbon electrodes [J].
Chicharro, M ;
Sánchez, A ;
Zapardiel, A ;
Rubianes, MD ;
Rivas, G .
ANALYTICA CHIMICA ACTA, 2004, 523 (02) :185-191
[9]   Recent advances in capillary electrophoresis and capillary electrochromatography of pollutants [J].
Dabek-Zlotorzynska, E ;
Chen, H ;
Ding, LY .
ELECTROPHORESIS, 2003, 24 (22-23) :4128-4149
[10]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984