Pulsed amperometric detection with poly(dimethylsiloxane)-fabricated capillary electrophoresis microchips for the determination of EPA priority pollutants

被引:39
作者
Ding, YS
Garcia, CD [1 ]
机构
[1] Univ Texas, Dept Chem, San Antonio, TX 78249 USA
[2] Peking Univ, Hlth Sci Ctr, Dept Biol Chem, Beijing 100083, Peoples R China
关键词
D O I
10.1039/b509405d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniaturized analytical system for separation and detection of three EPA priority phenolic pollutants, based on a poly(dimethylsiloxane)-fabricated capillary electrophoresis microchip and pulsed amperometric detection is described. The approach offers a rapid (less than 2 min), simultaneous measurement of three phenolic pollutants: phenol, 4,6-dinitro-o-cresol and pentachlorophenol. The highly stable response (RSD = 6.1%) observed for repetitive injections (n > 100) reflects the effectiveness of Au working electrode cleaned by pulsed amperometric detection. The effect of solution conditions, separation potential and detection waveform were optimized for both the separation and detection of phenols. Under the optimum conditions (5.0 mM phosphate buffer pH 5 12.4, detection potential: 0.7 V, separation potential: 1200 V, injection time: 10 s) the baseline separation of the three selected compounds was achieved. Limits of detection of 2.2 mu M (2.8 fmol), 0.9 mu M (1.1 fmol), and 1.3 mu M (1.6 fmol) were achieved for phenol, 4,6-dinitro-o-cresol and pentachlorophenol, respectively. A local city water sample and two over-the-counter sore-throat medicines were analyzed in order to demonstrate the capabilities of the proposed technique to face real applications.
引用
收藏
页码:208 / 214
页数:7
相关论文
共 81 条
[21]   Determination of levoglucosan from smoke samples using microchip capillary electrophoresis with pulsed amperometric detection [J].
García, CD ;
Engling, G ;
Herckes, P ;
Collett, JL ;
Henry, CS .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (02) :618-623
[22]   Direct detection of renal function markers using microchip CE with pulsed electrochemical detection [J].
Garcia, CD ;
Henry, CS .
ANALYST, 2004, 129 (07) :579-584
[23]   Enhanced determination of glucose by microchip electrophoresis with pulsed amperometric detection [J].
García, CD ;
Henry, CS .
ANALYTICA CHIMICA ACTA, 2004, 508 (01) :1-9
[24]   Versatile 3-channel high-voltage power supply for microchip capillary electrophoresis [J].
García, CD ;
Liu, Y ;
Anderson, P ;
Henry, CS .
LAB ON A CHIP, 2003, 3 (04) :324-328
[25]   Direct determination of carbohydrates, amino acids, and antibiotics by microchip electrophoresis with pulsed amperometric detection [J].
García, CD ;
Henry, CS .
ANALYTICAL CHEMISTRY, 2003, 75 (18) :4778-4783
[26]   Glassy carbon electrodes modified with different electropolymerized resol prepolymer mixtures for phenol and derivatives quantification [J].
Garcia, CD ;
Ortiz, PI .
ANALYTICAL SCIENCES, 1999, 15 (05) :461-465
[27]   Electrochemical characterization of glassy carbon electrodes modified by resol mixtures [J].
García, CD ;
De Pauli, CP ;
Ortiz, PI .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 510 (1-2) :115-119
[28]   Reflectometry applied to electrochemically generated phenoxy radical adsorption monitoring [J].
García, G ;
García, CD ;
Ortiz, PI ;
De Pauli, CP .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 519 (1-2) :53-59
[29]   Sample manipulation in micro total analytical systems [J].
Greenwood, PA ;
Greenway, GM .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (11) :726-740
[30]  
Holland LA, 2002, ELECTROPHORESIS, V23, P3649, DOI 10.1002/1522-2683(200211)23:21<3649::AID-ELPS3649>3.0.CO