Pulsed amperometric detection with poly(dimethylsiloxane)-fabricated capillary electrophoresis microchips for the determination of EPA priority pollutants

被引:39
作者
Ding, YS
Garcia, CD [1 ]
机构
[1] Univ Texas, Dept Chem, San Antonio, TX 78249 USA
[2] Peking Univ, Hlth Sci Ctr, Dept Biol Chem, Beijing 100083, Peoples R China
关键词
D O I
10.1039/b509405d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniaturized analytical system for separation and detection of three EPA priority phenolic pollutants, based on a poly(dimethylsiloxane)-fabricated capillary electrophoresis microchip and pulsed amperometric detection is described. The approach offers a rapid (less than 2 min), simultaneous measurement of three phenolic pollutants: phenol, 4,6-dinitro-o-cresol and pentachlorophenol. The highly stable response (RSD = 6.1%) observed for repetitive injections (n > 100) reflects the effectiveness of Au working electrode cleaned by pulsed amperometric detection. The effect of solution conditions, separation potential and detection waveform were optimized for both the separation and detection of phenols. Under the optimum conditions (5.0 mM phosphate buffer pH 5 12.4, detection potential: 0.7 V, separation potential: 1200 V, injection time: 10 s) the baseline separation of the three selected compounds was achieved. Limits of detection of 2.2 mu M (2.8 fmol), 0.9 mu M (1.1 fmol), and 1.3 mu M (1.6 fmol) were achieved for phenol, 4,6-dinitro-o-cresol and pentachlorophenol, respectively. A local city water sample and two over-the-counter sore-throat medicines were analyzed in order to demonstrate the capabilities of the proposed technique to face real applications.
引用
收藏
页码:208 / 214
页数:7
相关论文
共 81 条
[41]   Development of a microfabricated palladium decoupler/electrochemical detector for microchip capillary electrophoresis using a hybrid glass/poly(dimethylsiloxane) device [J].
Lacher, NA ;
Lunte, SM ;
Martin, RS .
ANALYTICAL CHEMISTRY, 2004, 76 (09) :2482-2491
[42]  
Lacher NA, 2001, ELECTROPHORESIS, V22, P2526, DOI 10.1002/1522-2683(200107)22:12<2526::AID-ELPS2526>3.0.CO
[43]  
2-K
[44]  
LaCourse WR, 1997, PULSED ELECTROCHEMIC
[45]   Dual fluorescence and electrochemical detection on an electrophoresis microchip [J].
Lapos, JA ;
Manica, DP ;
Ewing, AG .
ANALYTICAL CHEMISTRY, 2002, 74 (14) :3348-3353
[46]   Advances in the voltammetric analysis of small biologically relevant compounds [J].
Lawrence, NS ;
Beckett, EL ;
Davis, J ;
Compton, RG .
ANALYTICAL BIOCHEMISTRY, 2002, 303 (01) :1-16
[47]   SEPARATION OF THE 11 PRIORITY POLLUTANT PHENOLS BY CAPILLARY ZONE ELECTROPHORESIS [J].
LI, G ;
LOCKE, DC .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 669 (01) :93-102
[48]   Electrochemical stripping analysis of organophosphate pesticides and nerve agents [J].
Liu, GD ;
Lin, YH .
ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (04) :339-343
[49]   Recent developments in detection for microfluidic systems [J].
Mogensen, KB ;
Klank, H ;
Kutter, JP .
ELECTROPHORESIS, 2004, 25 (21-22) :3498-3512
[50]   In-field monitoring of cleaning efficiency in waste water treatment plants using two phenol-sensitive biosensors [J].
Nistor, C ;
Rose, A ;
Farré, M ;
Stoica, L ;
Wollenberger, U ;
Ruzgas, T ;
Pfeiffer, D ;
Barceló, D ;
Gorton, L ;
Emnéus, J .
ANALYTICA CHIMICA ACTA, 2002, 456 (01) :3-17