A Thermal Monitoring Sheet With Low Influence From Adjacent Waterbolus for Tissue Surface Thermometry During Clinical Hyperthermia

被引:10
作者
Arunachalam, Kavitha [1 ]
Maccarini, Paolo F. [1 ]
Stauffer, Paul R. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Hyperthermia Phys Div, Durham, NC 27713 USA
关键词
Heat transfer; hyperthermia; noninvasive thermometry; surface thermal modeling; temperature distribution measurement; thermal monitoring sheet;
D O I
10.1109/TBME.2008.925693
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
This paper presents a complete thermal analysis of a novel conformal surface thermometer design with directional sensitivity for real-time temperature monitoring during hyperthermia treatments of large superficial cancer. The thermal monitoring sheet (TMS) discussed in this paper consists of a 2-D array of fiberoptic sensors embedded between two layers of flexible, low-loss, and thermally conductive printed circuit board (PCB) film. Heat transfer across all interfaces from the tissue surface through multiple layers of insulating dielectrics surrounding the small buried temperature sensor and into an adjacent temperature-regulated water coupling bolus was studied using 3-D thermal simulation software. Theoretical analyses were carried out to identify the most effective differential TMS probe configuration possible with commercially available flexible PCB materials and to compare their thermal responses with omnidirectional probes commonly used in clinical hyperthermia. A TMS sensor design that employ's 0.0508-mm Kapton MTB and 0.2032-mm Kapton HN flexible polyimide films is proposed for tissue surface thermometry, with low influence from the adjacent waterbolus. Comparison of the thermal simulations with clinical probes indicates the new differential TMS probe design to outperform in terms of both transient response and steady-state accuracy in selectively reading the tissue surface temperature, while decreasing the overall thermal barrier of the probe between the coupling waterbolus and tissue surface.
引用
收藏
页码:2397 / 2406
页数:10
相关论文
共 29 条
[1]
[Anonymous], 2007, P SPIE
[2]
Performance evaluation of a conformal thermal monitoring sheet sensor array for measurement of surface temperature distributions during superficial hyperthermia treatments [J].
Arunachalam, K. ;
Maccarini, P. ;
Juang, T. ;
Gaeta, C. ;
Stauffer, P. R. .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2008, 24 (04) :313-325
[3]
Dewhirst M.W., 2003, CANC MED, P623
[4]
PRECLINICAL EVALUATION OF A MICROWAVE PLANAR ARRAY APPLICATOR FOR SUPERFICIAL HYPERTHERMIA [J].
DIEDERICH, CJ ;
STAUFFER, PR .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1993, 9 (02) :227-246
[5]
CURRENT SHEET APPLICATOR ARRAYS FOR SUPERFICIAL HYPERTHERMIA OF CHESTWALL LESIONS [J].
GOPAL, MK ;
HAND, JW ;
LUMORI, MLD ;
ALKHAIRI, S ;
PAULSEN, KD ;
CETAS, TC .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1992, 8 (02) :227-240
[6]
HAND JW, 1993, HYPERTHERMIC ONCOLOG, V2, P193
[7]
Incropera F., 2006, Fundamentals of Heat and Mass Transfer, V6th
[8]
JOHNSON B, 2006, LANDSCOPE, V22, P6
[9]
Randomized trial of hyperthermia and radiation for superficial tumors [J].
Jones, EL ;
Oleson, JR ;
Prosnitz, LR ;
Samulski, TV ;
Vujaskovic, Z ;
Yu, DH ;
Sanders, LL ;
Dewhirst, MW .
JOURNAL OF CLINICAL ONCOLOGY, 2005, 23 (13) :3079-3085
[10]
Multilayer conformal applicator for microwave heating and brachytherapy treatment of superficial tissue disease [J].
Juang, T. ;
Stauffer, P. R. ;
Neuman, D. G. ;
Schlorff, J. L. .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2006, 22 (07) :527-544