Gradient-based iterative image reconstruction scheme for time-resolved optical tomography

被引:204
作者
Hielscher, AH
Klose, AD
Hanson, KM
机构
[1] SUNY Downstate Med Ctr, Dept Pathol, Brooklyn, NY 11203 USA
[2] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
关键词
infrared imaging; optical tomography; time-resolved imaging; tomographic reconstruction; turbid media;
D O I
10.1109/42.764902
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Currently available tomographic image reconstruction schemes for optical tomography (OT) are mostly based on the limiting assumptions of small perturbations and a priori knowledge of the optical properties of a reference medium. Furthermore, these algorithms usually require the inversion of large, full, ill-conditioned Jacobian matrixes. in this work a gradient-based iterative image reconstruction (GIIR) method is presented that promises to overcome current limitations. The code consists of three major parts: 1) A finite-difference, time-resolved, diffusion forward model is used to predict detector readings based on the spatial distribution of optical properties; 2) An objective function that describes the difference between predicted and measured data; 3) An updating method that uses the gradient of the objective function in a line minimization scheme to provide subsequent guesses of the spatial distribution of the optical properties for the forward model. The reconstruction of these properties is completed, once a minimum of this objective function is found. After a presentation of the mathematical background, two- and three-dimensional reconstruction of simple heterogeneous media as well as the clinically relevant example of ventricular bleeding in the brain are discussed. Numerical studies suggest that intraventricular hemorrhages can be detected using the GIIR technique, even in the presence of a heterogeneous background.
引用
收藏
页码:262 / 271
页数:10
相关论文
共 86 条
[51]  
KLOSE AD, IN PRESS P SPIE INT
[52]   NEAR-INFRARED MEASUREMENT OF CEREBRAL OXYGENATION - CORRELATION WITH ELECTROENCEPHALOGRAPHIC ISCHEMIA DURING VENTRICULAR-FIBRILLATION [J].
LEVY, WJ ;
LEVIN, S ;
CHANCE, B .
ANESTHESIOLOGY, 1995, 83 (04) :738-746
[53]   CHARACTERIZATION OF ABSORPTION AND SCATTERING PROPERTIES OF SMALL-VOLUME BIOLOGICAL SAMPLES USING TIME-RESOLVED SPECTROSCOPY [J].
LIU, H ;
MIWA, M ;
BEAUVOIT, B ;
WANG, NG ;
CHANCE, B .
ANALYTICAL BIOCHEMISTRY, 1993, 213 (02) :378-385
[54]   Imaging experimental data from optical tomography by the elliptic systems method [J].
Lucas, TR ;
Klibanov, MV ;
Frank, RM .
COMPUTATIONAL, EXPERIMENTAL, AND NUMERICAL METHODS FOR SOLVING ILL-POSED INVERSE IMAGING PROBLEMS: MEDICAL AND NONMEDICAL APPLICATIONS, 1997, 3171 :22-33
[55]   Spatial and temporal analysis of human motor activity using noninvasive NIR topography [J].
Maki, A ;
Yamashita, Y ;
Ito, Y ;
Watanabe, E ;
Mayanagi, Y ;
Koizumi, H .
MEDICAL PHYSICS, 1995, 22 (12) :1997-2005
[56]  
Maki Atsushi, 1996, Frontiers of Medical and Biological Engineering, V7, P285
[57]  
Ment LR, 1996, PEDIATRICS, V98, P714
[58]   Cognitive outcome at 41/2 years of very low birth weight infants enrolled in the multicenter indomethacin intraventricular hemorrhage prevention trial [J].
Ment, LR ;
Westerveld, M ;
Makuch, R ;
Vohr, B ;
Allan, WC .
PEDIATRICS, 1998, 102 (01) :159-160
[59]  
Miwa M, 1995, P SOC PHOTO-OPT INS, V2389, P142
[60]  
Nioka S, 1997, ADV EXP MED BIOL, V411, P227