Gradient-based iterative image reconstruction scheme for time-resolved optical tomography

被引:204
作者
Hielscher, AH
Klose, AD
Hanson, KM
机构
[1] SUNY Downstate Med Ctr, Dept Pathol, Brooklyn, NY 11203 USA
[2] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
关键词
infrared imaging; optical tomography; time-resolved imaging; tomographic reconstruction; turbid media;
D O I
10.1109/42.764902
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Currently available tomographic image reconstruction schemes for optical tomography (OT) are mostly based on the limiting assumptions of small perturbations and a priori knowledge of the optical properties of a reference medium. Furthermore, these algorithms usually require the inversion of large, full, ill-conditioned Jacobian matrixes. in this work a gradient-based iterative image reconstruction (GIIR) method is presented that promises to overcome current limitations. The code consists of three major parts: 1) A finite-difference, time-resolved, diffusion forward model is used to predict detector readings based on the spatial distribution of optical properties; 2) An objective function that describes the difference between predicted and measured data; 3) An updating method that uses the gradient of the objective function in a line minimization scheme to provide subsequent guesses of the spatial distribution of the optical properties for the forward model. The reconstruction of these properties is completed, once a minimum of this objective function is found. After a presentation of the mathematical background, two- and three-dimensional reconstruction of simple heterogeneous media as well as the clinically relevant example of ventricular bleeding in the brain are discussed. Numerical studies suggest that intraventricular hemorrhages can be detected using the GIIR technique, even in the presence of a heterogeneous background.
引用
收藏
页码:262 / 271
页数:10
相关论文
共 86 条
[71]  
PRESS WH, 1992, NUMERICAL RECIPES C, P50
[72]  
RICHTMYER RD, 1967, DIFFERENCE METHODS I, P211
[73]   Cerebral oxygenation during warming after cardiopulmonary bypass [J].
Sapire, KJ ;
Gopinath, SP ;
Farhat, G ;
Thakar, DR ;
Gabrielli, A ;
Jones, JW ;
Robertson, CS ;
Chance, B .
CRITICAL CARE MEDICINE, 1997, 25 (10) :1655-1662
[74]   Model-based image reconstruction from time-resolved diffusion data [J].
Saquib, SS ;
Hanson, KM ;
Cunningham, GS .
IMAGE PROCESSING - MEDICAL IMAGING 1997, PTS 1 AND 2, 1997, 3034 :369-380
[75]   ML parameter estimation for Markov random fields with applications to Bayesian tomography [J].
Saquib, SS ;
Bouman, CA ;
Sauer, K .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1998, 7 (07) :1029-1044
[76]   PHOTON HITTING DENSITY [J].
SCHOTLAND, JC ;
HASELGROVE, JC ;
LEIGH, JS .
APPLIED OPTICS, 1993, 32 (04) :448-453
[77]   Direct calculation with a finite-element method of the Laplace transform of the distribution of photon time of flight in tissue [J].
Schweiger, M ;
Arridge, SR .
APPLIED OPTICS, 1997, 36 (34) :9042-9049
[78]  
SCHWEIGER M, 1996, OSA TRENDS OPTICS PH, V2, P263
[79]   Non-invasive measurements of breast tissue optical properties using frequency-domain photon migration [J].
Tromberg, BJ ;
Coquoz, O ;
Fishkin, J ;
Pham, T ;
Anderson, ER ;
Butler, J ;
Cahn, M ;
Gross, JD ;
Venugopalan, V ;
Pham, D .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 1997, 352 (1354) :661-668
[80]   Imaging brain injury using time-resolved near infrared light scanning [J].
vanHouten, JP ;
Benaron, DA ;
Spilman, S ;
Stevenson, DK .
PEDIATRIC RESEARCH, 1996, 39 (03) :470-476