Pseudoenhancement of simple renal cysts: A comparison of single and multidetector helical CT

被引:34
作者
Heneghan, JP [1 ]
Spielmann, AL [1 ]
Sheafor, DH [1 ]
Kliewer, MA [1 ]
DeLong, DM [1 ]
Nelson, RC [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
关键词
computed tomography; helical; kidney; cysts; contrast media;
D O I
10.1097/00004728-200201000-00013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this work was to compare the extent of pseudoenhancement (artifactual increase in measured attenuation of a simple cyst after contrast medium administration) in a phantom model on single detector and multidetector helical CT scanners. Method: The phantom consisted of four water-filled spheres varying in size from 8 to 28 mm, suspended in an aqueous contrast medium bath. Iodine concentration in the bath was varied: 0, 6, 12, and 24 mg/ml corresponding to attenuation values of 0, +108, +180, and +300 HU. The phantom was scanned on single detector and multidetector helical CT scanners during the same session. Collimation (1, 3, and 5 mm) and pitch (I and 1.5: 1, single detector; 3: 1 and 6: 1, multidetector) were varied at each concentration. All scans were performed at 140 kVp and 170 mA. The region of interest was measured at the center of each sphere. The effects were analyzed using a linear regression model. Results: The degree of pseudoenhancement was more pronounced with increasing iodine concentration, decreasing cyst size, and wider collimation (all p = 0.0001). Pseudoenhancement was also more marked on the multidetector than the single detector scanner (p = 0.0001). At physiological levels of renal enhancement, the average pseudoenhancement was +18 HU for the single detector versus +23 HU for the multidetector scanner. Variation in pitch had no effect. Conclusion: Pseudoenhancement is greater on a multidetector than a single detector helical CT scanner and may exceed 20 HU at physiological levels of renal enhancement.
引用
收藏
页码:90 / 94
页数:5
相关论文
共 7 条
[1]   Renal cysts: Is attenuation artifactually increased on contrast-enhanced CT images? [J].
Bae, KT ;
Heiken, JP ;
Siegel, CL ;
Bennett, HF .
RADIOLOGY, 2000, 216 (03) :792-796
[2]  
BOSNIAK MA, 1986, RADIOLOGY, V158, P1
[3]   Evaluation of pseudoenhancement of renal cysts during contrast-enhanced CT [J].
Coulam, CH ;
Sheafor, DH ;
Leder, RA ;
Paulson, EK ;
DeLong, DM ;
Nelson, RC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) :493-498
[4]   Four multidetector-row helical CT: Image quality and volume coverage speed [J].
Hu, H ;
He, HD ;
Foley, WD ;
Fox, SH .
RADIOLOGY, 2000, 215 (01) :55-62
[5]   Multi-slice helical CT: Scan and reconstruction [J].
Hu, H .
MEDICAL PHYSICS, 1999, 26 (01) :5-18
[6]   SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION [J].
KALENDER, WA ;
SEISSLER, W ;
KLOTZ, E ;
VOCK, P .
RADIOLOGY, 1990, 176 (01) :181-183
[7]   Renal cyst pseudoenhancement: Beam-hardening effects on CT numbers [J].
Maki, DD ;
Birnbaum, BA ;
Chakraborty, DP ;
Jacobs, JE ;
Carvalho, BM ;
Herman, GT .
RADIOLOGY, 1999, 213 (02) :468-472