Dual X-ray absorptiometry assessment of body composition in children with altered body posture

被引:18
作者
Lark, RK
Henderson, RC
Renner, JB
Fung, EB
Stallings, VA
Conaway, M
Stevenson, RD
机构
[1] Univ N Carolina, Dept Orthopaed, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Dept Radiol, Chapel Hill, NC 27599 USA
[3] Univ Penn, Sch Nursing, Philadelphia, PA 19104 USA
[4] Univ Penn, Dept Pediat, Philadelphia, PA 19104 USA
[5] Univ Virginia, Dept Biostat, Charlottesville, VA USA
[6] Univ Virginia, Dept Pediat, Charlottesville, VA USA
关键词
dual X-ray absorptiometry; body composition; children; nutritional status; developmental disabilities;
D O I
10.1385/JCD:4:4:325
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Many children have contractures and/or deformities that preclude positioning in a fully supine position. The purpose of this study was to evaluate the effects of "poor" positioning on the assessment of body composition with dual X-ray absorptiometry (DXA) in Thirty-seven normal child volunteers ages 3-16 yrs. Multiple whole-body DXA scans of each child were performed: duplicate scans in the correct fully supine position, two scans while simulating different positions typical of children with contractures, and a scan while positioned in the full lateral position as a "worst-case" scenario. Also evaluated were the precision of duplicate measures in the altered positions, the effect of knee flexion contractures, and the impact of metallic orthopedic fixation devices. Errors in body composition assessment did occur from "poor" positioning. In those positions simulating children with contractures, the mean errors were 4-6% for measures of bone mineral content, 1-3% for lean body mass, and 5-11 % for fat mass. Measures in the correct fully supine position and the contracted positions were highly correlated. The errors obtained by altering position were small. If errors of this magnitude are of significance, then corrective equations could be utilized to improve accuracy. Precise and reasonably accurate measures of body composition can be obtained with DXA in children with disabilities and deformities that preclude fully supine positioning.
引用
收藏
页码:325 / 335
页数:11
相关论文
共 20 条
[1]   Improvement in the accuracy of dual energy X-ray absorptiometry for whole body and regional analysis of body composition: Validation using piglets and methodologic considerations in infants [J].
Brunton, JA ;
Weiler, HA ;
Atkinson, SA .
PEDIATRIC RESEARCH, 1997, 41 (04) :590-596
[2]   Cross-calibration, precision and patient dose measurements in preparation for clinical trials using dual energy X-ray absorptiometry of the lumbar spine [J].
Cawte, SA ;
Pearson, D ;
Green, DJ ;
Maslanka, WB ;
Miller, CG ;
Rogers, AT .
BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (856) :354-362
[3]   Body composition in nutritionally adequate ambulatory and non-ambulatory children with cerebral palsy and a healthy reference group [J].
Chad, KE ;
McKay, HA ;
Zello, GA ;
Bailey, DA ;
Faulkner, RA ;
Snyder, RE .
DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 2000, 42 (05) :334-339
[4]   ACCURACY OF DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR BODY-COMPOSITION MEASUREMENTS IN CHILDREN [J].
ELLIS, KJ ;
SHYPAILO, RJ ;
PRATT, JA ;
POND, WG .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1994, 60 (05) :660-665
[5]  
Forbes A., 1999, MODERN NUTR HLTH DIS, P789
[6]  
GENANT HK, 1994, J BONE MINER RES, V9, P1503
[7]   Cross-calibration of body-composition techniques against dual-energy X-ray absorptiometry in young children [J].
Goran, MI ;
Driscoll, P ;
Johnson, R ;
Nagy, TR ;
Hunter, G .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1996, 63 (03) :299-305
[8]   Body-composition measurement in 9-11-y-old children by dual-energy X-ray absorptiometry, skinfold-thickness measurements, and bioimpedance analysis [J].
Gutin, B ;
Litaker, M ;
Islam, S ;
Manos, T ;
Smith, C ;
Treiber, F .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1996, 63 (03) :287-292
[9]   Lateral femoral scan: an alternative method for assessing bone mineral density in children with cerebral palsy [J].
Harcke, HT ;
Taylor, A ;
Bachrach, S ;
Miller, F ;
Henderson, RC .
PEDIATRIC RADIOLOGY, 1998, 28 (04) :241-246
[10]  
KOO WWK, 1995, J BONE MINER RES, V10, P1998