Comparison of BOLD contrast and Gd-DTPA dynamic contrast-enhanced imaging in rat prostate tumor

被引:41
作者
Jiang, L [1 ]
Zhao, DW [1 ]
Constantinescu, A [1 ]
Mason, RP [1 ]
机构
[1] Univ Texas, SW Med Ctr, Dept Radiol, Dallas, TX 75390 USA
关键词
BOLD; dynamic contrast-enhanced MRI; prostate tumor; oxygen; Gd-DTPA;
D O I
10.1002/mrm.20069
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The microcirculation and oxygenation of a tumor play important roles in its responsiveness to cytotoxic treatment, and noninvasive assessments of its vascular properties may have prognostic value. Dynamic contrast-enhanced (DCE) H-1 MRI based on infusion of Gd-DTPA, and blood oxygen level-dependent (BOLD) contrast based on altering inhaled gas are both sensitive to vascular characteristics. This study compares the effects observed in eight Dunning prostate R3327-AT1 rat tumors imaged sequentially at 4.7 Tesla by echo-planar imaging (EPI). Both interventions generated a significant response, and each revealed significant differences between the center and periphery of the tumors. On a voxel-by-voxel basis across the whole tumor population, there was a close correlation between the maximum rate of signal response and the magnitude of response to each intervention (R-2 greater than or equal to 0.6, P < 0.0001). However, when the data were analyzed separately for each individual tumor, some showed a weak correlation (R-2 < 0.4), particularly for DCE, and the nature (slope) varied between separate tumors. Generally, there was a weak correlation (N = 7, R2 < 0.5) between responses to the two interventions on a tumor-by-tumor basis, which emphasizes that the techniques are not equivalent. Both techniques revealed intra- and intertumor heterogeneity, but the BOLD response was more rapidly reversible than the DCE response. This suggests that the BOLD technique may be a useful tool for investigating interventions (such as drugs) that cause vascular disruption. Magn Reson Med 51: 953-960, 2004. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:953 / 960
页数:8
相关论文
共 31 条
[11]   Effect of carbogen on tumor oxygenation: Combined fluorine-19 and proton MRI measurements [J].
Fan, XB ;
River, JN ;
Zamora, M ;
Al-Hallaq, HA ;
Karczmar, GS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (04) :1202-1209
[12]   The response of human tumors to carbogen breathing, monitored by Gradient-Recalled Echo Magnetic Resonance Imaging [J].
Griffiths, JR ;
Taylor, NJ ;
Howe, FA ;
Saunders, MI ;
Robinson, SP ;
Hoskin, PJ ;
Powell, MEB ;
Thoumine, M ;
Caine, LA ;
Baddeley, H .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (03) :697-701
[13]   ISOLATED TUMOR-GROWTH IN A SURGICALLY FORMED SKIN PEDICLE IN THE RAT - A NEW TUMOR-MODEL FOR NMR-STUDIES [J].
HAHN, EW ;
PESCHKE, P ;
MASON, RP ;
BABCOCK, EE ;
ANTICH, PP .
MAGNETIC RESONANCE IMAGING, 1993, 11 (07) :1007-1017
[14]   Flow and oxygenation dependent (flood) contrast MR imaging to monitor the response of rat tumors to carbogen breathing [J].
Howe, FA ;
Robinson, SP ;
Rodrigues, LM ;
Griffiths, JR .
MAGNETIC RESONANCE IMAGING, 1999, 17 (09) :1307-1318
[15]   Tumor oximetry: Demonstration of an enhanced dynamic mapping procedure using fluorine-19 echo planar magnetic resonance imaging in the Dunning prostate R3327-AT1 rat tumor [J].
Hunjan, S ;
Zhao, DW ;
Constantinescu, A ;
Hahn, EW ;
Antich, PP ;
Mason, RP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (04) :1097-1108
[16]   Changes in tumor oxygenation/perfusion induced by the NO donor, isosorbide dinitrate, in comparison with carbogen: Monitoring by EPR and MRI [J].
Jordan, BF ;
Misson, PD ;
Demeure, R ;
Baudelet, C ;
Beghein, N ;
Gallez, B .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02) :565-570
[17]   Molecular imaging in prostate cancer [J].
Karam, JA ;
Mason, RP ;
Koeneman, KS ;
Antich, PP ;
Benaim, EA ;
Hsieh, JT .
JOURNAL OF CELLULAR BIOCHEMISTRY, 2003, 90 (03) :473-483
[18]   Interplay of tumor vascular oxygenation and tumor pO2 observed using near-infrared spectroscopy, an oxygen needle electrode, and 19F MR pO2 mapping [J].
Kim, JG ;
Zhao, DW ;
Song, YL ;
Constantinescu, A ;
Mason, RP ;
Liu, HL .
JOURNAL OF BIOMEDICAL OPTICS, 2003, 8 (01) :53-62
[19]   BOLD contrast fMRI of whole rodent tumour during air or carbogen breathing using echo-planar imaging at 1.5 T [J].
Landuyt, W ;
Hermans, R ;
Bosmans, H ;
Sunaert, S ;
Béatse, E ;
Farina, D ;
Meijerink, M ;
Zhang, H ;
Van den Bogaert, W ;
Lambin, P ;
Marchal, G .
EUROPEAN RADIOLOGY, 2001, 11 (11) :2332-2340
[20]   Noninvasive investigation of blood oxygenation dynamics of tumors by near-infrared spectroscopy [J].
Liu, HL ;
Song, YL ;
Worden, KL ;
Jiang, X ;
Constantinescu, A ;
Mason, RP .
APPLIED OPTICS, 2000, 39 (28) :5231-5243