Osteoconductive coatings for total joint arthroplasty

被引:174
作者
Geesink, RGT [1 ]
机构
[1] Univ Hosp Maastricht, Dept Orthopaed Surg, NL-6202 AZ Maastricht, Netherlands
关键词
D O I
10.1097/00003086-200202000-00007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Osteoconductive calcium phosphate coatings for total joint arthroplasty have been in clinical use since the mid1980s. The basic principles involved and basic science evidence for the efficacy of osteoconductive coatings were examined. Hydroxyapatite coatings provide consistent and better filling with bone of the gaps and spaces around cementless joint components after surgery as compared with porous-coated implant surfaces, resulting in better implant stability. Of all the calcium phosphate coatings, hydroxyapatite coatings have had the most widespread application in hip arthroplasty. Their clinical advantages over more conventional implant surfaces are evident in primary and revision hip arthroplasties. A clinical survival rate in the author's series of 97 % at a minimum of 11 years followup for the femoral component in a young active patient population (average age, 53 years) was obtained with no mechanical failures. The average polyethylene wear rate in this group was 0.129 mm/year. In a similar group of young patients with revision arthroplasty using hydroxyapatite-coated femoral components, an 11-year survival rate of 93 % was obtained. Histologic analysis of specimens retrieved at autopsy confirmed the excellent bony fixation of components. Advantages of the more recent biomimetic hydroxyapatite coatings were examined.
引用
收藏
页码:53 / 65
页数:13
相关论文
共 115 条
[61]  
Kumar M, 1999, J BIOMED MATER RES, V45, P302, DOI 10.1002/(SICI)1097-4636(19990615)45:4<302::AID-JBM4>3.0.CO
[62]  
2-A
[63]  
Lacefield W R, 1998, Implant Dent, V7, P315, DOI 10.1097/00008505-199807040-00010
[64]  
Leeuwenburgh S, 2001, J BIOMED MATER RES, V56, P208, DOI 10.1002/1097-4636(200108)56:2<208::AID-JBM1085>3.0.CO
[65]  
2-R
[66]  
Li PJ, 1998, J BIOMED MATER RES, V41, P341, DOI 10.1002/(SICI)1097-4636(19980905)41:3<341::AID-JBM1>3.3.CO
[67]  
2-P
[68]   Osteogenic protein 1 device stimulates bone healing to hydroxyapaptite-coated and titanium implants [J].
Lind, M ;
Overgaard, S ;
Song, Y ;
Goodman, SB ;
Bünger, C ;
Soballe, K .
JOURNAL OF ARTHROPLASTY, 2000, 15 (03) :339-346
[69]   EFFECT OF FEMORAL-HEAD SIZE ON WEAR OF THE POLYETHYLENE ACETABULAR COMPONENT [J].
LIVERMORE, J ;
ILSTRUP, D ;
MORREY, B .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (04) :518-528
[70]  
Lu HH, 2000, J BIOMED MATER RES, V51, P80, DOI 10.1002/(SICI)1097-4636(200007)51:1<80::AID-JBM11>3.0.CO