Delayed Gadolinium-enhanced MR Imaging of Articular Cartilage: Three-dimensional T1 Mapping with Variable Flip Angles and B1 Correction

被引:37
作者
Andreisek, Gustav [1 ,2 ,6 ]
White, Lawrence M. [1 ,2 ]
Yang, Yi [3 ,7 ]
Robinson, Emma [1 ,2 ]
Cheng, Hai-Ling Margaret [3 ,4 ]
Sussman, Marshall S. [5 ]
机构
[1] Univ Toronto, Dept Med Imaging, Mt Sinai Hosp, Toronto, ON, Canada
[2] Univ Toronto, Univ Hlth Network, Toronto, ON, Canada
[3] Univ Toronto, Hosp Sick Children, Res Inst, Toronto, ON M5G 1X8, Canada
[4] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 1X8, Canada
[5] Univ Toronto, Dept Med Imaging, Toronto Gen Hosp, Toronto, ON M5G 1X8, Canada
[6] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[7] Hebei Med Univ, Hosp 4, Ultrasound Diagnost Imaging Dept, Shijiazhuang, Hebei, Peoples R China
关键词
LOCKER METHOD; GLYCOSAMINOGLYCAN; OSTEOARTHRITIS; ACCURACY; 3.0T;
D O I
10.1148/radiol.2531081115
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: To develop and verify the accuracy of a rapid imaging protocol for delayed gadolinium-enhanced magnetic resonance (MR) imaging of cartilage that was based on three-dimensional (3D) spoiled gradient-recalled acquisition in the steady state (SPGR) sequences with variable flip angles (FAs) (VFAs) and where a correction method for B-1 field inhomogeneities was applied. Materials and Methods: The institutional research ethics board approved this study. Written informed consent was obtained from all subjects. A B1 field inhomogeneity correction method was applied to a 3D SPGR pulse sequence with VFAs (repetition time msec/echo time msec, 7.1/3.3; FAs, 2 degrees, 5 degrees, 10 degrees, and 20 degrees) and was used to perform delayed gadolinium-enhanced MR imaging of cartilage 3D T1 measurements at 1.5 T. The 3D T1 measurements were validated with the reference standard ( the results of T1 mapping by using a single-section two-dimensional [2D] inversion-recovery [IR] fast spin-echo [SE] pulse sequence in vitro and in vivo) in six healthy volunteers. Results: T1 values calculated from 3D T1 maps were not significantly different from reference T1 values in vitro (P = .195) and in vivo (P = .52) when a B1 field inhomogeneity correction method was applied. In vivo T1 mapping of the articular surface of the whole femoropatellar joint, including data acquisition, was performed in approximately 8 minutes of acquisition time at a spatial resolution of 0.55 x 0.55 x 3.00 mm. Conclusion: Rapid T1 mapping by using 3D SPGR acquisitions with a VFA approach and a correction for B1 field inhomogeneities can be used for delayed gadolinium-enhanced MR imaging of cartilage. T1 measurements performed in vitro and in vivo by using this approach are highly accurate when compared with those performed by using standard 2D IR fast SE T1 mapping as a reference.
引用
收藏
页码:865 / 873
页数:9
相关论文
共 26 条
[1]
Glycosaminoglycan in articular cartilage: In vivo assessment with delayed Gd(DTPA)(2-)-enhanced MR imaging [J].
Bashir, A ;
Gray, ML ;
Boutin, RD ;
Burstein, D .
RADIOLOGY, 1997, 205 (02) :551-558
[2]
Bashir A, 1999, MAGNET RESON MED, V41, P857, DOI 10.1002/(SICI)1522-2594(199905)41:5<857::AID-MRM1>3.0.CO
[3]
2-E
[4]
Gd-DTPA(2-) as a measure of cartilage degradation [J].
Bashir, A ;
Gray, ML ;
Burstein, D .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (05) :665-673
[5]
Brookes JA, 1999, JMRI-J MAGN RESON IM, V9, P163, DOI 10.1002/(SICI)1522-2586(199902)9:2<163::AID-JMRI3>3.0.CO
[6]
2-L
[7]
Burstein D, 2001, MAGNET RESON MED, V45, P36, DOI 10.1002/1522-2594(200101)45:1<36::AID-MRM1006>3.0.CO
[8]
2-W
[9]
Rapid high-resolution T1 mapping by variable flip angles:: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity [J].
Cheng, HLM ;
Wright, GA .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :566-574
[10]
SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil [J].
Collins, CM ;
Li, SZ ;
Smith, MB .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) :847-856