7T Head Volume Coils: Improvements for Rostral Brain Imaging

被引:20
作者
Avdievich, Nikolai I. [1 ]
Hetherington, Hoby P. [1 ]
Kuznetsov, Andrey M. [1 ]
Pan, Jullie W. [1 ]
机构
[1] Yale Univ, Dept Neurosurg, MRRC TAC, New Haven, CT 06520 USA
基金
美国国家卫生研究院;
关键词
TEM; RF volume head coil; homogeneity improvement; high field MRI; AMYOTROPHIC-LATERAL-SCLEROSIS; ARRAY; TRANSMIT; 4T;
D O I
10.1002/jmri.21660
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To improve the performance of 7T head coils over the rostral head regions. Due to radiofrequency (RF) field/tissue interactions, the RF magnetic field profile produced by 7T volume head coils is very inhomogeneous, with enhanced sensitivity near the center of the human brain and substantially reduced in the periphery. Materials and Methods: Two head-sized quadrature volume coils of similar diameters but substantially different lengths (17 and 10 cm) were constructed and tested using a 7T Varian Inova system. Results: Experimental data demonstrated that by using a shorter volume head-sized coil or simply by partially moving a head out of the coil, coil efficiency near the top of a head can be improved by 20%. The homogeneity also improved, largely resulting from an increase in peripheral B-1 values. This resulted in 10%-20% variation in axial slices located near the top of a head. Conclusion: We have demonstrated a less deeply positioned head or substantially shorter volume coil can significantly improve coil performance and homogeneity for the rostral head at ultrahigh magnetic fields (7T and above). For studies that target superior brain regions, this coil arrangement can be highly effective.
引用
收藏
页码:461 / 465
页数:5
相关论文
共 17 条
[1]   Transmit and receive transmission line arrays for 7 tesla parallel imaging [J].
Adriany, G ;
Van de Moortele, PF ;
Wiesinger, F ;
Moeller, S ;
Strupp, JP ;
Andersen, P ;
Snyder, C ;
Zhang, XL ;
Chen, W ;
Pruessmann, KP ;
Boesiger, P ;
Vaughan, T ;
Ugurbil, K .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) :434-445
[2]   4T actively detunable transmit/receive transverse electromagnetic coil and 4-channel receive-only phased array for 1H human brain studies [J].
Avdievich, NI ;
Hetherington, HP .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (06) :1459-1464
[3]   Central brightening due to constructive interference with, without, and despite dielectric resonance [J].
Collins, CM ;
Liu, WZ ;
Schreiber, W ;
Yang, QX ;
Smith, MB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (02) :192-196
[4]   Combination of optimized transmit arrays and some receive array reconstruction methods can yield homogeneous images at very high frequencies [J].
Collins, CM ;
Liu, W ;
Swift, BJ ;
Smith, MB .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (06) :1327-1332
[5]   Effect of RF coil excitation on field inhomogeneity at ultra high fields: A field optimized TEM resonator [J].
Ibrahim, TS ;
Lee, R ;
Baertlein, BA ;
Abduljalil, AM ;
Zhu, H ;
Robitaille, PML .
MAGNETIC RESONANCE IMAGING, 2001, 19 (10) :1339-1347
[6]   Detection of cerebral degeneration in amyotrophic lateral sclerosis using high-field magnetic resonance spectroscopy [J].
Kalra, Sanjay ;
Hanstock, Christopher C. ;
Martin, W. R. Wayne ;
Allen, Peter S. ;
Johnston, Wendy S. .
ARCHIVES OF NEUROLOGY, 2006, 63 (08) :1144-1148
[7]   Frontal lobe GABA levels in cocaine dependence: a two-dimensional, J-resolved magnetic resonance spectroscopy study [J].
Ke, Y ;
Streeter, CC ;
Nassar, LE ;
Sarid-Segal, F ;
Hennen, J ;
Yurgelun-Todd, DA ;
Awad, LA ;
Rendall, MJ ;
Gruber, SA ;
Nason, A ;
Mudrick, MJ ;
Blank, SR ;
Meyer, AA ;
Knapp, C ;
Ciraulo, DA ;
Renshaw, PF .
PSYCHIATRY RESEARCH-NEUROIMAGING, 2004, 130 (03) :283-293
[8]  
Nabetani A, 2006, P 14 ANN M ISMRM SEA, P2608
[9]   Quantitative spectroscopic imaging of the human brain [J].
Pan, JW ;
Twieg, DB ;
Hetherington, HP .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) :363-369
[10]  
TROPP J, 2001, P WORKSH MRI HARDW C, P11