Development of a combined setup for simultaneous detection of total and glycated haemoglobin content in blood samples

被引:37
作者
Pribyl, J
Skládal, P
机构
[1] Masaryk Univ, Dept Biochem, CS-61137 Brno, Czech Republic
[2] Masaryk Univ, Natl Ctr Biomol Res, CS-61137 Brno, Czech Republic
关键词
piezoelectric biosensor; quartz crystal microbalance; absorbance; 3-aminophenylboronic acid; glycated haemoglobin;
D O I
10.1016/j.bios.2005.09.007
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An original setup for analysis of glycated haemoglobin (HbA,) in blood is reported. The construction employed a combination of the piezoelectric biosensor for glycated haemoglobin and the flow-through photometric sensor for total haemoglobin (Hb). The modification of gold electrodes with 3-aminophenylboronic acid (APBA) as a specific ligand was studied; the chemisorbed conjugate of APBA with a long-chain thiocompound provided the best affinity for Hb(A1c). The effect of various operating parameters, such as flow rate and instrumental setup, was optimised. The total haemoglobin content was analysed as absorbance of the haemoglobin-cyanide derivative at 540 nm. Only one standard (calibrator) diluted in various ratio was necessary for calibration and 1 mu l of blood was sufficient for analysis. The full range of Hb(A1c) content (4-15%) in blood can be analysed; the working ranges of total and glycated haemoglobin were 50-2000 and 10-90 mu g/ml, respectively. The developed method was successfully evaluated on blood samples collected from diabetics. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1952 / 1959
页数:8
相关论文
共 30 条
[1]   Saccharide sensing using gold and silver nanoparticles - A review [J].
Aslan, K ;
Zhang, J ;
Lakowicz, JR ;
Geddes, CD .
JOURNAL OF FLUORESCENCE, 2004, 14 (04) :391-400
[2]   Comparison of hemoglobin A1C results by two different methods on patients with structural hemoglobin variants [J].
Blakney, GB ;
Higgins, TN ;
Holmes, DJ .
CLINICAL BIOCHEMISTRY, 1998, 31 (08) :619-626
[3]   SELECTIVE EXTRACTION OF QUERCETRIN IN VEGETABLE DRUGS AND URINE BY OFF-LINE COUPLING OF BORONIC ACID AFFINITY-CHROMATOGRAPHY AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BONGARTZ, D ;
HESSE, A .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 673 (02) :223-230
[4]   Equilibrium and kinetic analyses of the interactions between vitamin B12 binding proteins and cobalamins by surface plasmon resonance [J].
Cannon, MJ ;
Myszka, DG ;
Bagnato, JD ;
Alpers, DH ;
West, FG ;
Grissom, CB .
ANALYTICAL BIOCHEMISTRY, 2002, 305 (01) :1-9
[5]   The synthesis and screening of a combinatorial peptide library for affinity ligands for glycosylated haemoglobin [J].
Chen, B ;
Bestetti, G ;
Day, RM ;
Turner, APF .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8) :779-785
[6]   EQUILIBRIA BETWEEN BORATE ION AND SOME POLYOLS IN AQUEOUS SOLUTION [J].
CONNER, JM ;
BULGRIN, VC .
JOURNAL OF INORGANIC & NUCLEAR CHEMISTRY, 1967, 29 (08) :1953-&
[7]  
*FIALAB INSTR, 2000, FIALAB 3500 OP MAN
[8]  
HERMANSON GT, 1996, BIOCONJUGATE TECHNIQ
[9]   Improved direct piezoelectric biosensors operating in liquid solution for the competitive label-free immunoassay of 2,4-dichlorophenoxyacetic acid [J].
Horacek, J ;
Skladal, P .
ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) :43-50
[10]  
International committee for standardization in haematology, 1977, J CLIN PATHOL, V31, P139