An original setup for analysis of glycated haemoglobin (HbA,) in blood is reported. The construction employed a combination of the piezoelectric biosensor for glycated haemoglobin and the flow-through photometric sensor for total haemoglobin (Hb). The modification of gold electrodes with 3-aminophenylboronic acid (APBA) as a specific ligand was studied; the chemisorbed conjugate of APBA with a long-chain thiocompound provided the best affinity for Hb(A1c). The effect of various operating parameters, such as flow rate and instrumental setup, was optimised. The total haemoglobin content was analysed as absorbance of the haemoglobin-cyanide derivative at 540 nm. Only one standard (calibrator) diluted in various ratio was necessary for calibration and 1 mu l of blood was sufficient for analysis. The full range of Hb(A1c) content (4-15%) in blood can be analysed; the working ranges of total and glycated haemoglobin were 50-2000 and 10-90 mu g/ml, respectively. The developed method was successfully evaluated on blood samples collected from diabetics. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1952 / 1959
页数:8
相关论文
共 30 条
[21]   Electrochemical sensing of fluoride and sugars with a boronic acid-substituted bipyridine Fe(II) complex in solution and attached onto an electrode surface [J].
Nicolas, M ;
Fabre, B ;
Simonet, J .
ELECTROCHIMICA ACTA, 2001, 46 (08) :1179-1190
[22]   Fluorescence-based glucose sensors [J].
Pickup, JC ;
Hussain, F ;
Evans, ND ;
Rolinski, OJ ;
Birch, DJS .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) :2555-2565
[23]   Quartz crystal biosensor for detection of sugars and glycated hemoglobin [J].
Pribyl, J ;
Skládal, P .
ANALYTICA CHIMICA ACTA, 2005, 530 (01) :75-84
[24]   VERWENDUNG VON SCHWINGQUARZEN ZUR WAGUNG DUNNER SCHICHTEN UND ZUR MIKROWAGUNG [J].
SAUERBREY, G .
ZEITSCHRIFT FUR PHYSIK, 1959, 155 (02) :206-222
[25]   Investigation of osteoprotegerin interactions with ligands and antibodies using piezoelectric biosensors [J].
Skládal, P ;
Jílková, Z ;
Svoboda, I ;
Kolár, V .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (10) :2027-2034
[26]   A detailed examination of boronic acid-diol complexation [J].
Springsteen, G ;
Wang, BH .
TETRAHEDRON, 2002, 58 (26) :5291-5300
[27]   A piezoelectric sensor with propidium as a recognition element for cholinesterases [J].
Teller, C ;
Halámek, J ;
Makower, A ;
Fournier, D ;
Schulze, H ;
Scheller, FW .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (01) :214-221
[28]   A self assembled shell of 11-mercaptoundecanoic aminophenylboronic acids on gold nanoclusters [J].
Valina-Saba, M ;
Bauer, G ;
Stich, N ;
Pittner, F ;
Schalkhammer, T .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 1999, 8-9 :205-209
[29]   STUDIES ON BORATE ESTERS .2. STRUCTURE AND STABILITY OF BORATE ESTERS OF POLYHYDROXYCARBOXYLATES AND RELATED POLYOLS IN AQUEOUS ALKALINE MEDIA AS STUDIED BY B-11 NMR [J].
VANDUIN, M ;
PETERS, JA ;
KIEBOOM, APG ;
VANBEKKUM, H .
TETRAHEDRON, 1985, 41 (16) :3411-3421
[30]   Determination of proteins with Alizarin Red S by Rayleigh light scattering technique [J].
Zhong, H ;
Li, N ;
Zhao, FL ;
Li, KA .
TALANTA, 2004, 62 (01) :37-42