Fluorescence-based glucose sensors

被引:474
作者
Pickup, JC [1 ]
Hussain, F
Evans, ND
Rolinski, OJ
Birch, DJS
机构
[1] Guys Hosp, Dept Chem Pathol, Guys Kings & St Thomas Sch Med, London SE1 9RT, England
[2] Univ Strathclyde, Dept Phys, Glasgow G4 0NG, Lanark, Scotland
基金
英国惠康基金;
关键词
diabetes mellitus; biosensor; glucose monitoring; glucose sensor; fluorescence; non-invasive monitoring; fluorescence resonance energy transfer;
D O I
10.1016/j.bios.2004.10.002
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
There is an urgent need to develop technology for continuous in vivo glucose monitoring in subjects with diabetes mellitus. Problems with existing devices based on electrochemistry have encouraged alternative approaches to glucose sensing in recent years, and those based on fluorescence intensit and lifetime have special advantages, including sensitivity and the potential for non-invasive measurement when near-infrared light is used. Several receptors have been employed to detect glucose in fluorescence sensors, and these include the lectin concanavalin A (Con A), enzymes such as glucose oxidase, glucose dehydrogenase and hexokinase/glucokinase, bacterial glucose-binding protein, and boronic acid derivatives (which bind the diols of sugars). Techniques include measuring changes in fluorescence resonance energy transfer (FRET) between a fluorescent donor and an acceptor either within a protein which undergoes glucose-induced changes in conformation or because of competitive displacement; measurement of glucose-induced changes in intrinsic fluorescence of enzymes (e.g. due to tryptophan residues in hexokinase) or extrinsic fluorophores (e.g. using environmentally sensitive fluorophores to signal protein conformation). Noninvasive glucose monitoring can be accomplished by measurement of cell autofluorescence due to NAD(P)H, and fluorescent markers of mitochondrial metabolism can signal changes in extracellular glucose concentration. Here we review the principles of operation, context and current status of the various approaches to fluorescence-based glucose sensing. (c) 2004 Elsevier B. V. All rights reserved.
引用
收藏
页码:2555 / 2565
页数:11
相关论文
共 68 条
[1]  
[Anonymous], 1991, TOPICS FLUORESCENCE
[2]  
[Anonymous], INT TXB DIABETES
[3]   A D-glucose selective fluorescent assay [J].
Arimori, S ;
Ward, CJ ;
James, TD .
TETRAHEDRON LETTERS, 2002, 43 (02) :303-305
[4]   A fluorescence affinity hollow fiber sensor for continuous transdermal glucose monitoring [J].
Ballerstadt, R ;
Schultz, JS .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :4185-4192
[5]   In vitro long-term performance study of a near-infrared fluorescence affinity sensor for glucose monitoring [J].
Ballerstadt, R ;
Polak, A ;
Beuhler, A ;
Frye, J .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (08) :905-914
[6]   PHOTOINDUCED ELECTRON-TRANSFER AS A GENERAL DESIGN LOGIC FOR FLUORESCENT MOLECULAR SENSORS FOR CATIONS [J].
BRYAN, AJ ;
DE SILVA, AP ;
DESILVA, SA ;
RUPASINGHE, RADD ;
SANDANAYAKE, KRAS .
BIOSENSORS, 1989, 4 (03) :169-179
[7]   Luminescent quantum dots for multiplexed biological detection and imaging [J].
Chan, WCW ;
Maxwell, DJ ;
Gao, XH ;
Bailey, RE ;
Han, MY ;
Nie, SM .
CURRENT OPINION IN BIOTECHNOLOGY, 2002, 13 (01) :40-46
[8]   Fluorescence resonance energy transfer between quantum dot donors and dye-labeled protein acceptors [J].
Clapp, AR ;
Medintz, IL ;
Mauro, JM ;
Fisher, BR ;
Bawendi, MG ;
Mattoussi, H .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (01) :301-310
[9]   A thermophilic apoglucose dehydrogenase as nonconsuming glucose sensor [J].
D'Auria, S ;
Di Cesare, N ;
Gryczynski, Z ;
Gryczynski, I ;
Rossi, M ;
Lakowicz, JR .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2000, 274 (03) :727-731
[10]   The fluorescence emission of the apo-glucose oxidase from Aspergillus niger as probe to estimate glucose concentrations [J].
D'Auria, S ;
Herman, P ;
Rossi, M ;
Lakowicz, JR .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1999, 263 (02) :550-553