Imaging of the lungs using 3He MRI: Preliminary clinical experience in 18 patients with and without lung disease

被引:174
作者
Kauczor, HU
Ebert, M
Kreitner, KF
Nilgens, H
Surkau, R
Heil, W
Hofmann, D
Otten, EW
Thelen, M
机构
[1] Department of Radiology, Johannes Gutenberg-University Mainz, 55131 Mainz
[2] Institute of Physics, Johannes Gutenberg-University Mainz, 55131 Mainz
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1997年 / 7卷 / 03期
关键词
lung; MR; contrast enhancement; nuclei other than H; hyperpolarized inert gases;
D O I
10.1002/jmri.1880070314
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to describe the 3He MRI findings of normal pulmonary ventilation in healthy volunteers and to evaluate abnormalities in patients with different lung diseases, Hyperpolarized 3He gas (300 ml, 3 x 10(5) Pa, polarized to 35-45% by optical pumping, provided in special glass cells) was inhaled by 8 healthy volunteers and 10 patients with different lung diseases. Imaging was performed with a three-dimensional fast low-angle shot (FLASH) sequence (TR = 11.8 msec; TE = 5 msec; transmitter amplitude, 5-8 V; corresponding nip angle, <5 degrees) in a single breath-hold (22-42 seconds). Clinical and radiologic examinations were available for correlation, The studies were performed successfully in eight of eight volunteers and in 8 of 10 patients, The lung parenchyma of volunteers with normal ventilatory function exhibited rather homogeneous intermediate to high signal, whereas patients with chronic obstructive lung disease or bronchiectasis presented with severe signal inhomogeneities with patchy or wedge-shaped defects, The mass effect of bronchogenic carcinoma, chronic empyema, lymphadenopathy, or pleural effusion caused large signal defects, representing the lesion and adjacent hypoventilation, the extent of which had not been presumed from chest x-ray or CT. 3He MRI is a promising new modality for the assessment of pulmonary ventilation and its abnormalities. Additional studies are needed to determine its potential clinical role.
引用
收藏
页码:538 / 543
页数:6
相关论文
共 10 条
  • [1] Nuclear magnetic resonance imaging of airways in humans with use of hyperpolarized He-3
    Bachert, P
    Schad, LR
    Bock, M
    Knopp, MV
    Ebert, M
    Grossmann, T
    Heil, W
    Hofmann, D
    Surkau, R
    Otten, EW
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (02) : 192 - 196
  • [2] In vivo He-3 MR images of guinea pig lungs
    Black, RD
    Middleton, HL
    Cates, GD
    Cofer, GP
    Driehuys, B
    Happer, W
    Hedlund, LW
    Johnson, GA
    Shattuck, MD
    Swartz, JC
    [J]. RADIOLOGY, 1996, 199 (03) : 867 - 870
  • [3] Nuclear magnetic resonance imaging with hyperpolarised helium-3
    Ebert, M
    Grossmann, T
    Heil, W
    Otten, WE
    Surkau, R
    Leduc, M
    Bachert, P
    Knopp, MV
    Schad, LR
    Thelen, M
    [J]. LANCET, 1996, 347 (9011) : 1297 - 1299
  • [4] A DENSE POLARIZED HE-3 TARGET BASED ON COMPRESSION OF OPTICALLY PUMPED GAS
    ECKERT, G
    HEIL, W
    MEYERHOFF, M
    OTTEN, EW
    SURKAU, R
    WERNER, M
    LEDUC, M
    NACHER, PJ
    SCHEARER, LD
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 320 (1-2) : 53 - 65
  • [5] VERY LONG NUCLEAR-RELAXATION TIMES OF SPIN-POLARIZED HELIUM-3 IN METAL-COATED CELLS
    HEIL, W
    HUMBLOT, H
    OTTEN, E
    SCHAFER, M
    SARKAU, R
    LEDUC, M
    [J]. PHYSICS LETTERS A, 1995, 201 (04) : 337 - 343
  • [6] HEIL W, 1997, IN PRESS J NEUTRON R
  • [7] Normal and abnormal pulmonary ventilation: Visualization at hyperpolarized He-3 MR imaging
    Kauczor, HU
    Hofmann, D
    Kreitner, KF
    Nilgens, H
    Surkau, R
    Heil, W
    Potthast, A
    Knopp, MV
    Otten, EW
    Thelen, M
    [J]. RADIOLOGY, 1996, 201 (02) : 564 - 568
  • [8] Human lung air spaces: Potential for MR imaging with hyperpolarized He-3
    MacFall, JR
    Charles, HC
    Black, RD
    Middleton, H
    Swartz, JC
    Saam, B
    Driehuys, B
    Erickson, C
    Happer, W
    Cates, GD
    Johnson, GA
    Ravin, CE
    [J]. RADIOLOGY, 1996, 200 (02) : 553 - 558
  • [9] MR-IMAGING WITH HYPERPOLARIZED HE-3 GAS
    MIDDLETON, H
    BLACK, RD
    SAAM, B
    CATES, GD
    COFER, GP
    GUENTHER, R
    HAPPER, W
    HEDLUND, LW
    JOHNSON, GA
    JUVAN, K
    SWARTZ, J
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (02) : 271 - 275
  • [10] NUCLEAR-RELAXATION OF HE-3 IN THE PRESENCE OF O-2
    SAAM, B
    HAPPER, W
    MIDDLETON, H
    [J]. PHYSICAL REVIEW A, 1995, 52 (01): : 862 - 865