Sub-10 cm3 interferometric accelerometer with nano-g resolution

被引:88
作者
Loh, NC
Schmidt, MA
Manalis, SR
机构
[1] MIT, Media Lab, Cambridge, MA 02139 USA
[2] MIT, Dept Elect Engn & Comp Sci, Microsyst Technol Labs, Cambridge, MA 02139 USA
基金
美国国家科学基金会;
关键词
D O I
10.1109/JMEMS.2002.1007396
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A high-resolution accelerometer with a bulk-micro-machined silicon proof mass and an interferometric position sensor was developed for measuring vibratory accelerations. The interferometer consists of interdigitated fingers that are alternately attached to the proof mass and support substrate. Illuminating the ringers with coherent light generates a series of diffracted beams. The intensity of a given beam depends on the out-of-plane separation between the proof mass fingers and support fingers. Proof masses with mechanical resonances ranging from 80 Hz to 1 kHz were fabricated with a two mask process involving two deep reactive ion etches, an oxide etch stop, and a polyimide protective layer. The structures were packaged with a laser diode and photodiode into 8.6-cm(3) acrylic housings. The 80-Hz resonant proof mass has a noise equivalent acceleration of 40 ng/rt Hz and a dynamic range of 85 dB at 40 Hz.
引用
收藏
页码:182 / 187
页数:6
相关论文
共 14 条
[1]   Technique for measurement of the noise of a sensor in the presence of large background signals [J].
Barzilai, A ;
VanZandt, T ;
Kenny, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (07) :2767-2772
[2]   High-resolution micromachined interferometric accelerometer [J].
Cooper, EB ;
Post, ER ;
Griffith, S ;
Levitan, J ;
Manalis, SR ;
Schmidt, MA ;
Quate, CF .
APPLIED PHYSICS LETTERS, 2000, 76 (22) :3316-3318
[3]   MECHANICAL-THERMAL NOISE IN MICROMACHINED ACOUSTIC AND VIBRATION SENSORS [J].
GABRIELSON, TB .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1993, 40 (05) :903-909
[4]   Characterization of a high-sensitivity micromachined tunneling accelerometer with micro-g resolution [J].
Liu, CH ;
Barzilai, AM ;
Reynolds, JK ;
Partridge, A ;
Kenny, TW ;
Grade, JD ;
Rockstad, HK .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 1998, 7 (02) :235-244
[5]  
LIU CS, 1999, P TRANSD 99 JUN 7 10, P1290
[6]  
LOH NC, 2001, THESIS MIT CAMBRIDGE
[7]   Interdigital cantilevers for atomic force microscopy [J].
Manalis, SR ;
Minne, SC ;
Atalar, A ;
Quate, CF .
APPLIED PHYSICS LETTERS, 1996, 69 (25) :3944-3946
[8]  
MINNE SC, 1999, BRINGING SCANNING PR
[9]  
NOVAC MJ, 1992, THESIS MIT CAMBRIDGE
[10]   A miniature, high-sensitivity, electron tunneling accelerometer [J].
Rockstad, HK ;
Tang, TK ;
Reynolds, JK ;
Kenny, TW ;
Kaiser, WJ ;
Gabrielson, TB .
SENSORS AND ACTUATORS A-PHYSICAL, 1996, 53 (1-3) :227-231