Detection of fiducial gold markers for automatic on-line megavoltage position verification using a marker extraction kernel (MEK)

被引:74
作者
Nederveen, A [1 ]
Lagendijk, J [1 ]
Hofman, P [1 ]
机构
[1] Univ Utrecht, Med Ctr, Dept Radiat Oncol, NL-3584 CX Utrecht, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2000年 / 47卷 / 05期
关键词
portal imaging; gold markers; position verification; detection algorithm;
D O I
10.1016/S0360-3016(00)00523-X
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: In this study automatic detection of implanted gold markers in megavoltage portal images for on-line position verification was investigated, Methods and Materials: A detection method for fiducial gold markers, consisting of a marker extraction kernel (MEK), was developed. The detection success rate was determined for different markers using this MEK. The localization accuracy was investigated by measuring distances between markers, which were fixed on a perspex template. In order to generate images comparable to images of patients with implanted markers, this template was placed on the skin of patients before the start of the treatment, Portal images were taken of lateral prostate fields at 18 MV within 1-2 monitor units (MU). Results: The detection success rates for markers of 5 mm length and 1.2 and 1.4 mm diameter were 0.95 and 0.99 respectively when placed at the beam entry and 0.39 and 0.86 when placed at the beam exit. The localization accuracy appears to be better than 0.6 mm for all markers. Conclusion: Automatic marker detection with an acceptable accuracy at the start of a radiotherapy fraction is feasible, Further minimization of marker diameters may be achieved with the help of an a-Si flat panel imager and may increase the clinical acceptance of this technique. (C) 2000 Elsevier Science Inc.
引用
收藏
页码:1435 / 1442
页数:8
相关论文
共 33 条
[1]   Initial performance evaluation of an indirect-detection, active matrix flat-panel imager (AMFPI) prototype for megavoltage imaging [J].
Antonuk, LE ;
El-Mohri, Y ;
Huang, WD ;
Jee, KW ;
Siewerdsen, JH ;
Maolinbay, M ;
Scarpine, VE ;
Sandler, H ;
Yorkston, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (02) :437-454
[2]   Tumor and target delineation: Current research and future challenges [J].
AustinSeymour, M ;
Chen, GTY ;
Rosenman, J ;
Michalski, J ;
Lindsley, K ;
Goitein, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1041-1052
[3]   Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibility [J].
Balter, JM ;
Lam, KL ;
Sandler, HM ;
Littles, JF ;
Bree, RL ;
TenHaken, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1281-1286
[4]   MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[5]   Analysis of prostate and seminal vesicle motion: Implications for treatment planning [J].
Beard, CJ ;
Kijewski, P ;
Bussiere, M ;
Gelman, R ;
Gladstone, D ;
Shaffer, K ;
Plunkett, M ;
Costello, P ;
Coleman, CN .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (02) :451-458
[6]   High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging [J].
Bel, A ;
Vos, PH ;
Rodrigus, PTR ;
Creutzberg, CL ;
Visser, AG ;
Stroom, JC ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :321-332
[7]   High-precision conformal radiotherapy (HPCRT) of prostate cancer -: A new technique for exact positioning of the prostate at the time of treatment [J].
Bergström, P ;
Löfroth, PO ;
Widmark, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (02) :305-311
[8]   HIERARCHICAL CHAMFER MATCHING - A PARAMETRIC EDGE MATCHING ALGORITHM [J].
BORGEFORS, G .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1988, 10 (06) :849-865
[9]   A REVIEW OF ELECTRONIC PORTAL IMAGING DEVICES (EPIDS) [J].
BOYER, AL ;
ANTONUK, L ;
FENSTER, A ;
VANHERK, M ;
MEERTENS, H ;
MUNRO, P ;
REINSTEIN, LE ;
WONG, J .
MEDICAL PHYSICS, 1992, 19 (01) :1-16
[10]  
CAI J, 1996, MED PHYS, V23, P2096