Separation/preconcentration of trace amounts of Cr, Cu and Pb in environmental samples by magnetic solid-phase extraction with Bismuthiol-II-immobilized magnetic nanoparticles and their determination by ICP-OES

被引:200
作者
Suleiman, Jibrin Sabo [1 ]
Hu, Bin [1 ]
Peng, Hanyong [1 ]
Huang, Chaozhang [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
关键词
Separation/preconcentration; Cr; Cu and Pb; Environmental samples; Magnetic nanoparticles; Bismuthiol-II; ICP-OES; ATOMIC EMISSION-SPECTROMETRY; SIZED TITANIUM-DIOXIDE; ONLINE PRECONCENTRATION; MICRO-COLUMN; METAL-IONS; AES DETERMINATION; CARBON NANOTUBES; CELL-SORPTION; SILICA; ENRICHMENT;
D O I
10.1016/j.talanta.2008.09.049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method for separation/preconcentration of trace amounts of Cr, Cu and Pb in environmental samples by magnetic solid-phase extraction (SPE) with Bismuthiol-II-immobilized magnetic nanoparticles and their determination by ICP-OES has been developed. The separation of the target analytes from the aqueous solution containing the target analytes and Bismuthiol-II-immobilized magnetic nanoparticles was simply achieved by applying external magnetic field. Optimal experimental conditions including pH, sample volume, eluent concentration and Volume and co-existing ions have been studied and established. Under the optimal experimental conditions, the detection limits for Cr, Cu and Pb with enrichment factors of 96, 95 and 87 were found to be 0.043, 0.058 and 0.085 ng mL(-1) and their relative standard deviations (R.S.D.s) were 3.5%, 4.6% and 3.7% (n = 5, C = 2 ng mL(-1)), respectively. The method was validated with certified reference material (GBW50009-88) of environmental water sample and the analytical results coincided well with the certified values. Furthermore, the method was Successfully applied to the determination of target analytes in river and lake water samples. Compared with established methods, the proposed method is characterized with high enrichment factor. fast separation and low detection limits. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1579 / 1583
页数:5
相关论文
共 34 条
[21]   γ-MPTMS modified nanometer-sized alumina micro-column separation and preconcentration of trace amounts of Hg, Cu, Au and Pd in biological, environmental and geological samples and their determination by inductively coupled plasma mass spectrometry [J].
Pu, XL ;
Jiang, ZC ;
Hu, B ;
Wang, HB .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (08) :984-989
[22]   Sorption of divalent metal ions from aqueous solution by carbon nanotubes: A review [J].
Rao, Gadupudi Purnachadra ;
Lu, Chungsying ;
Su, Fengsheng .
SEPARATION AND PURIFICATION TECHNOLOGY, 2007, 58 (01) :224-231
[23]   Biosorption of heavy metals on Aspergillus fumigatus immobilized Diaion HP-2MG resin for their atomic absorption spectrometric determinations [J].
Soylak, Mustafa ;
Tuzen, Mustafa ;
Mendil, Durali ;
Turkekul, Ibrahim .
TALANTA, 2006, 70 (05) :1129-1135
[24]   Interpretation of transition metal sorption behavior by oxidized active carbons and other adsorbents [J].
Strelko, V ;
Malik, DJ ;
Streat, M .
SEPARATION SCIENCE AND TECHNOLOGY, 2004, 39 (08) :1885-1905
[25]   Cloud point extraction preconcentration for capillary electrophoresis of metal ions [J].
Tang, AN ;
Jiang, DQ ;
Yan, XP .
ANALYTICA CHIMICA ACTA, 2004, 507 (02) :199-204
[26]   Quantification of magnetic nanoparticles by magnetorelaxometry and comparison to histology after magnetic drug targeting [J].
Wiekhorst, F. ;
Seliger, C. ;
Jurgons, R. ;
Steinhoff, U. ;
Eberbeck, D. ;
Trahms, L. ;
Alexiou, C. .
JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2006, 6 (9-10) :3222-3225
[27]   Magnetite-containing spherical silica nanoparticles for biocatalysis and bioseparations [J].
Yang, HH ;
Zhang, SQ ;
Chen, XL ;
Zhuang, ZX ;
Xu, JG ;
Wang, XR .
ANALYTICAL CHEMISTRY, 2004, 76 (05) :1316-1321
[28]   On-line separation and preconcentration of trace metals in biological samples using a microcolumn loaded with PAN-modified nanometer-sized titanium dioxide, and their determination by ICP-AES [J].
Yang, LH ;
Hu, B ;
Jiang, ZC ;
Pan, HL .
MICROCHIMICA ACTA, 2004, 144 (04) :227-231
[29]   Simultaneous on-line preconcentration and determination of trace metals in environmental samples by flow injection combined with inductively coupled plasma mass spectrometry using a manometer-sized alumina packed micro-column [J].
Yin, J ;
Jiang, ZC ;
Chang, G ;
Hu, B .
ANALYTICA CHIMICA ACTA, 2005, 540 (02) :333-339
[30]   Chromium(III)-imprinted silica gel for speciation analysis of chromium in environmental water samples with ICP-MS detection [J].
Zhang, Nan ;
Suleiman, Jibrin Sabo ;
He, Man ;
Hu, Bin .
TALANTA, 2008, 75 (02) :536-543