Modified gold surfaces by 6-(ferrocenyl)hexanethiol/dendrimer/gold nanoparticles as a platform for the mediated biosensing applications

被引:38
作者
Karadag, Murat [1 ]
Geyik, Caner [1 ]
Demirkol, Dilek Odaci [1 ]
Ertas, F. Nil [2 ]
Timur, Suna [1 ]
机构
[1] Ege Univ, Fac Sci, Dept Biochem, TR-35100 Bornova, Turkey
[2] Ege Univ, Fac Sci, Dept Chem, TR-35100 Bornova, Turkey
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2013年 / 33卷 / 02期
关键词
Glucose biosensor; Gold nanoparticles; Self assembled monolayers; FLOW-INJECTION ANALYSIS; GLUCOSE-OXIDASE; ENZYME IMMOBILIZATION; COVALENT ATTACHMENT; CARBON NANOTUBES; DENDRIMER LAYERS; AU ELECTRODE; CONSTRUCTION; MONOLAYERS; MEMBRANE;
D O I
10.1016/j.msec.2012.10.008
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
An electrochemical biosensor mediated by using 6-(Ferrocenyl) hexanethiol (FcSH) was fabricated by construction of gold nanoparticles (AuNPs) on the surface of polyamidoamine dendrimer (PAMAM) modified gold electrode. Glucose oxidase (GOx) was used as a model enzyme and was immobilized onto the gold surface forming a self assembled monolayer via FcSH and cysteamine. Cyclic voltammetry and amperometry were used for the characterization of electrochemical response towards glucose substrate. Following the optimization of medium pH, enzyme loading, AuNP and FcSH amount, the linear range for the glucose was studied and found as 1.0 to 5.0 mM with the detection limit (LOD) of 0.6 mM according to S/N = 3. Finally, the proposed Au/AuNP/(FcSH + Cyst)/PAMAM/GOx biosensor was successfully applied for the glucose analysis in beverages, and the results were compared with those obtained by HPLC. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:634 / 640
页数:7
相关论文
共 41 条
[11]  
2-Z
[12]   Applications of nanobiotechnology in clinical diagnostics [J].
Jain, Kewal K. .
CLINICAL CHEMISTRY, 2007, 53 (11) :2002-2009
[13]  
KRAJEWSKA B, 1990, J CHEM TECHNOL BIOT, V48, P337
[14]   Immobilization of glucose oxidase on carbon paper electrodes modified with conducting polymer and its application to a glucose fuel cell [J].
Kuwahara, Takashi ;
Ohta, Hokuto ;
Kondo, Mizuki ;
Shimomura, Masato .
BIOELECTROCHEMISTRY, 2008, 74 (01) :66-72
[15]   GENERAL EXPRESSION OF THE LINEAR POTENTIAL SWEEP VOLTAMMOGRAM IN THE CASE OF DIFFUSIONLESS ELECTROCHEMICAL SYSTEMS [J].
LAVIRON, E .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1979, 101 (01) :19-28
[16]   Direct electrochemistry of glucose oxidase entrapped in nano gold particles-ionic liquid-N,N-dimethylformamide composite film on glassy carbon electrode and glucose sensing [J].
Li, Jiangwen ;
Yu, Jingjing ;
Zhao, Faqiong ;
Zeng, Baizhao .
ANALYTICA CHIMICA ACTA, 2007, 587 (01) :33-40
[17]   Gold nanoparticle-based biosensors [J].
Li, Yuanyuang ;
Schluesener, Hermann J. ;
Xu, Shunqing .
GOLD BULLETIN, 2010, 43 (01) :29-41
[18]   A hydrogen peroxide biosensor based on nano-Au/PAMAM dendrimer/cystamine modified gold electrode [J].
Liu, ZM ;
Yang, Y ;
Wang, H ;
Liu, YL ;
Shen, GL ;
Yu, RQ .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 106 (01) :394-400
[19]   Application of nanoparticles in electrochemical sensors and biosensors [J].
Luo, XL ;
Morrin, A ;
Killard, AJ ;
Smyth, MR .
ELECTROANALYSIS, 2006, 18 (04) :319-326
[20]   Biosensing Applications of Modified Core-Shell Magnetic Nanoparticles [J].
Ozdemir, Caglar ;
Akca, Ozlet ;
Medine, E. Ilker ;
Demirkol, Dilek Odaci ;
Unak, Perihan ;
Timur, Suna .
FOOD ANALYTICAL METHODS, 2012, 5 (04) :731-736