The electron storage ring BESSY II as a primary source standard from the visible to the X-ray range

被引:40
作者
Thornagel, R [1 ]
Klein, R [1 ]
Ulm, G [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
D O I
10.1088/0026-1394/38/5/3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Physikalisch-Technische Bundesanstalt (PTB) has used the BESSY I 800 MeV electron storage ring as a primary source standard since 1984. The calculable spectral photon flux Phi(E) of a bending magnet with relative uncertainties of 4 x 10(-4) to 4 x 10(-3) for the photon energy range 1 eV to 15 keV was used in a broad spectral range from the visible to the soft X-ray range for the calibration of radiation sources and energy-dispersive X-ray detectors. In 1998, BESSY II was brought into operation. Owing to its higher electron energy, of 1.7 GeV, the useful spectral range could be extended significantly into the X-ray region up to a photon energy of about 50 keV, while special storage-ring operation at 900 MeV results in a spectrum up to about 7 keV. The PTB has established BESSY II as a European primary source standard from the visible to the X-ray range by setting up equipment for the measurement of all storage-ring parameters and geometrical quantities involved in the calculation of PE according to Schwinger. At BESSY II, Phi(E) from a bending magnet can be calculated with a relative standard uncertainty of 3 x 10(-4) for photon energies below 3 keV, rising to 2 x 10(-3) at 50 keV.
引用
收藏
页码:385 / 389
页数:5
相关论文
共 26 条
[1]   ELECTRON STORAGE RING BESSY AS A SOURCE OF CALCULABLE SPECTRAL PHOTON FLUX IN THE X-RAY REGION [J].
ARNOLD, D ;
ULM, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :1539-1542
[2]   SURF III - an improved storage ring for radiometry [J].
Arp, U ;
Friedman, R ;
Furst, ML ;
Makar, S ;
Shaw, PS .
METROLOGIA, 2000, 37 (05) :357-360
[3]   High-accuracy calibration of the HXDS flow proportional counter for AXAF at the PTB laboratory at BESSY [J].
Auerhammer, JM ;
Brandt, G ;
Scholze, F ;
Thomagel, R ;
Ulm, G ;
Wargelin, BJ ;
McDermott, WC ;
Norton, TJ ;
Evans, IN ;
Kellogg, EM .
X-RAY OPTICS, INSTRUMENTS, AND MISSIONS, 1998, 3444 :19-29
[4]   X-ray CCD calibration for the AXAF CCD imaging spectrometer [J].
Bautz, M ;
Pivovaroff, M ;
Baganoff, F ;
Isobe, T ;
Jones, S ;
Kissel, S ;
LaMarr, B ;
Manning, H ;
Prigozhin, G ;
Ricker, G ;
Nousek, J ;
Grant, C ;
Nishikida, K ;
Scholze, F ;
Thornagel, R ;
Ulm, G .
X-RAY OPTICS, INSTRUMENTS, AND MISSIONS, 1998, 3444 :210-224
[5]   MEASUREMENTS OF THE ABSOLUTE SPECTRAL SENSITIVITY OF X-RAY SEMICONDUCTOR-DETECTORS IN THE PHOTON ENERGY-RANGE OF 1.5-15 KEV USING WHITE SR BEAM OF THE VEPP-3 STORAGE-RING [J].
DOLBNYA, IP ;
MAKAROV, OA ;
MEZENTSEV, NA ;
PINDYURIN, VF ;
SUBBOTIN, AN .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 359 (1-2) :427-431
[6]   RADIOMETRY BASED ON SYNCHROTRON RADIATION FROM THE STORAGE RING VEPP-2M [J].
GLUSKIN, ES ;
KUZMINIKH, VS ;
MAKAROV, OA ;
OGURTSOV, VI .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :397-399
[7]   The quantum efficiency of the XMM pn-CCD camera [J].
Hartmann, R ;
Hartner, G ;
Briel, UG ;
Dennerl, K ;
Haberl, F ;
Strüder, L ;
Trümper, J ;
Bihler, E ;
Kendziorra, E ;
Hochedez, JF ;
Jourdain, E ;
Dhez, P ;
Salvetat, P ;
Auerhammer, J ;
Schmitz, D ;
Scholze, F ;
Ulm, G .
EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 :703-713
[8]   HOLLOW-CATHODE TRANSFER STANDARDS FOR THE RADIOMETRIC CALIBRATION OF VUV TELESCOPES OF THE SOLAR AND HELIOSPHERIC OBSERVATORY (SOHO) [J].
HOLLANDT, J ;
HUBER, MCE ;
KUHNE, M .
METROLOGIA, 1993, 30 (04) :381-388
[9]  
*IRD, AXUV 100 SI PHOT
[10]   Measurement of the electron energy and energy spread at the electron storage ring BESSY I [J].
Klein, R ;
Mayer, T ;
Kuske, P ;
Thornagel, R ;
Ulm, G .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :392-394