Silica sol-gel immobilized amperometric biosensor for hydrogen peroxide

被引:289
作者
Li, J
Tan, SN
Ge, HL
机构
[1] NANYANG TECHNOL UNIV,NATL INST EDUC,DIV CHEM,SINGAPORE 259756,SINGAPORE
[2] SINGAPORE PROD & STAND BOARD,SINGAPORE 118221,SINGAPORE
关键词
sol-gel technique; peroxide; horseradish peroxidase; amperometry; flow injection; hexacyanoferrate(II);
D O I
10.1016/S0003-2670(96)00337-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric enzyme electrode for hydrogen peroxide was developed via easy and effective enzyme immobilization using the sol-gel technique. The enzyme electrode comprises horseradish peroxidase (HRP) immobilized in the silica sol-gel matrix on a carbon paste electrode (CPE). Hydrogen peroxide was detected in the presence of hexacyanoferrate(II) as a mediator to transfer electrons between the electrode surface and hydrogen peroxide. The effects of operational parameters such as the operating potential of the working electrode, mediator concentration and pH, and thermal stability, were explored for optimum analytical performance by using an amperometric method. Linear calibration for hydrogen peroxide was obtained in the range 2x10(-5) to 2.6x10(-3) M under the optimized conditions. The apparent Michaelis-Menten constant of the enzyme electrode was 4.8 mM. The performance of this enzyme electrode was also investigated using flow-injection analysis. The enzyme electrode retained about 60% of its activity after 35 days of storage in a phosphate buffer at 4 degrees C.
引用
收藏
页码:137 / 145
页数:9
相关论文
共 26 条
[1]   ELECTROCHEMICAL PROBING OF THE ACTIVITY OF GLUCOSE-OXIDASE EMBEDDED SOL-GEL MATRICES [J].
AUDEBERT, P ;
DEMAILLE, C ;
SANCHEZ, C .
CHEMISTRY OF MATERIALS, 1993, 5 (07) :911-913
[2]   ORGANIC-CHEMISTRY WITHIN CERAMIC MATRICES - DOPED SOL-GEL MATERIALS [J].
AVNIR, D .
ACCOUNTS OF CHEMICAL RESEARCH, 1995, 28 (08) :328-334
[3]   BIOCHEMICALLY ACTIVE SOL-GEL GLASSES - THE TRAPPING OF ENZYMES [J].
BRAUN, S ;
RAPPOPORT, S ;
ZUSMAN, R ;
AVNIR, D ;
OTTOLENGHI, M .
MATERIALS LETTERS, 1990, 10 (1-2) :1-5
[4]  
Cass A.E.G., 1990, BIOSENSORS PRACTICAL, P218
[5]   CHEMICALLY IMMOBILIZED ENZYME ELECTRODES FOR HYDROGEN-PEROXIDE DETERMINATION [J].
COSGROVE, M ;
MOODY, GJ ;
THOMAS, JDR .
ANALYST, 1988, 113 (12) :1811-1815
[6]   SOL-GEL ENCAPSULATION METHODS FOR BIOSENSORS [J].
DAVE, BC ;
DUNN, B ;
VALENTINE, JS ;
ZINK, JI .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :A1120-A1127
[7]   ELECTROCATALYSIS AND FLOW-INJECTION ANALYSIS OF HYDROGEN-PEROXIDE AT A CHEMICALLY MODIFIED ELECTRODE [J].
GAO, ZQ ;
IVASKA, A ;
LI, P ;
LUI, KZ ;
YANG, JJ .
ANALYTICA CHIMICA ACTA, 1992, 259 (02) :211-218
[8]   SOL-GEL VANADIUM PENTAOXIDE GLUCOSE BIOSENSOR [J].
GLEZER, V ;
LEV, O .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1993, 115 (06) :2533-2534
[9]  
Guibault G., 1984, ANAL USES IMMOBILIZE
[10]   ORGANICALLY MODIFIED SOL-GEL SENSORS [J].
LEV, O ;
TSIONSKY, M ;
RABINOVICH, L ;
GLEZER, V ;
SAMPATH, S ;
PANKRATOV, I ;
GUN, J .
ANALYTICAL CHEMISTRY, 1995, 67 (01) :A22-A30