Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study

被引:115
作者
Barao, Valentim A. R. [1 ]
Mathew, Mathew T. [2 ]
Assuncao, Wirley Goncalves [1 ]
Yuan, Judy Chia-Chun [3 ]
Wimmer, Markus A. [2 ]
Sukotjo, Cortino [3 ]
机构
[1] Univ Estadual Paulista UNESP, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, Aracatuba, SP, Brazil
[2] Rush Univ, Med Ctr, Dept Orthoped Surg, Chicago, IL 60612 USA
[3] Univ Illinois, Coll Dent, Dept Restorat Dent, Chicago, IL 60612 USA
基金
巴西圣保罗研究基金会;
关键词
artificial saliva; corrosion; electrochemistry; pH level; titanium; CORROSION BEHAVIOR; SURFACE-ROUGHNESS; PURE TITANIUM; FLUORIDE; FATIGUE; WEAR;
D O I
10.1111/j.1600-0501.2011.02265.x
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
Objectives To investigate the role of different levels of pH of artificial saliva under simulated oral environment on the corrosion behavior of commercially pure titanium (cp-Ti) and Ti-6Al-4V alloy. Special attention is given to understand the changes in corrosion kinetics and surface characterization of Ti by using electrochemical impedance spectroscopy (EIS). Materials and methods Fifty-four Ti disks (15-mm diameter, 2-mm thickness) were divided into six groups (n similar to=similar to 9) as a function of saliva pH (3, 6.5, and 9) and Ti type. Samples were mechanically polished using standard metallographic procedures. Standard electrochemical tests, such as open circuit potential, EIS, and potentiodynamic tests were conducted in a controlled environment. Data were evaluated by two-way ANOVA, Tukey multiple comparison test, and independent t-test (a similar to=similar to 0.05). Ti surfaces were examined using white-light-interferometry microscopy and scanning electron microscopy (SEM). Results Saliva pH level significantly affected the corrosion behavior of both Ti types. At low pH, acceleration of ions exchange between Ti and saliva, and reduction of resistance of Ti surface against corrosion were observed (P similar to<similar to 0.05). Corrosion rate was also significantly increased in acidic medium (P similar to<similar to 0.05). Similar corrosion behavior was observed for both Ti types. The white-light-interferometry images of Ti surfaces show higher surface changes at low pH level. SEM images do not show detectable changes. No pitting corrosion was observed for any group. Conclusions The pH level of artificial saliva influences the corrosion behavior of cp-Ti and Ti-6Al-4V alloy in that lower pH accelerates the corrosion rate and kinetics. The corrosion products may mitigate the survival rate of dental implants.
引用
收藏
页码:1055 / 1062
页数:8
相关论文
共 32 条
[1]
The Role of Lipopolysaccharide on the Electrochemical Behavior of Titanium [J].
Barao, V. A. ;
Mathew, M. T. ;
Assuncao, W. G. ;
Yuan, J. C. ;
Wimmer, M. A. ;
Sukotjo, C. .
JOURNAL OF DENTAL RESEARCH, 2011, 90 (05) :613-618
[2]
The influence of abutment surface roughness on plaque accumulation and peri-implant mucositis [J].
Bollen, CML ;
Papaioanno, W ;
VanEldere, J ;
Schepers, E ;
Quirynen, M ;
vanSteenberghe, D .
CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (03) :201-211
[3]
Chaturvedi T P, 2009, Indian J Dent Res, V20, P91
[4]
Fatigue and Fluoride Corrosion on Streptococcus mutans Adherence to Titanium-Based Implant/Component Surfaces [J].
Correa, Cassia Bellotto ;
Pires, Juliana Rico ;
Fernandes-Filho, Romeu Belon ;
Sartori, Rafael ;
Vaz, Luis Geraldo .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2009, 18 (05) :382-387
[5]
Galvanic corrosion behavior of titanium implants coupled to dental alloys [J].
Cortada, M ;
Giner, LL ;
Costa, S ;
Gil, FJ ;
Rodríguez, D ;
Planell, JA .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2000, 11 (05) :287-293
[6]
Corrosion characterization of titanium alloys by electrochemical techniques [J].
de Assis, SL ;
Wolynec, S ;
Costa, I .
ELECTROCHIMICA ACTA, 2006, 51 (8-9) :1815-1819
[7]
Periprosthetic electrochemical corrosion of titanium and titanium-based alloys as a cause of spinal fusion failure [J].
Denaro, Vincenzo ;
Papapietro, Nicola ;
Sgambato, Alessandro ;
Barnaba, Simona A. ;
Ruzzini, Laura ;
De Paola, Barbara ;
Rettino, Alessandro ;
Cittadini, Achille .
SPINE, 2008, 33 (01) :8-13
[8]
Plaque pH and associated parameters in relation to caries [J].
Dong, YM ;
Pearce, EIF ;
Yue, L ;
Larsen, MJ ;
Gao, XJ ;
Wang, JD .
CARIES RESEARCH, 1999, 33 (06) :428-436
[9]
Gregory-Head BL, 2000, J PROSTHET DENT, V83, P675, DOI 10.1016/S0022-3913(00)70070-9
[10]
Effect of fluoride and albumin concentration on the corrosion behavior of Ti-6Al-4V alloy [J].
Huang, HH .
BIOMATERIALS, 2003, 24 (02) :275-282