Dual-Source Dual-Energy CT Evaluation of Complex Cystic Renal Masses

被引:83
作者
Ascenti, Giorgio [1 ]
Mazziotti, Silvio [1 ]
Mileto, Achille [1 ]
Racchiusa, Sergio [1 ]
Donato, Rocco [1 ]
Settineri, Nicola [1 ]
Gaeta, Michele [1 ]
机构
[1] Univ Messina, Dept Radiol Sci, Policlin G Martino, I-98125 Messina, Italy
关键词
color-coded iodine overlay images; complex cystic renal masses; dual-source dual-energy CT; radiation dose; virtual nonenhanced images; HYPERVASCULAR LIVER-TUMORS; LOW TUBE VOLTAGE; MULTIDETECTOR CT; CLASSIFICATION-SYSTEM; INITIAL OBSERVATIONS; CLINICAL-EXPERIENCE; IODINE OVERLAY; PHANTOM; REPAIR; PSEUDOENHANCEMENT;
D O I
10.2214/AJR.11.7711
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
OBJECTIVE. The purpose of this study was to assess the value of dual-source dual-energy CT in the evaluation of complex cystic renal masses. SUBJECTS AND METHODS. Seventy patients underwent contrast-enhanced dual-energy CT that included true unenhanced images acquired in single-energy mode, corticomedullary phase images acquired in dual-energy mode, and nephrographic phase images acquired in single-energy mode. Virtual unenhanced, blended weighted-average, and color-coded iodine overlay images were reconstructed. The acceptance level and image quality of virtual and true unenhanced images were evaluated. Contrast enhancement on both true unenhanced or blended weighted-average images and color-coded iodine overlay images was evaluated with both calculation in regions of interest and use of confidence level scales. Radiation dose parameters were estimated. RESULTS. Virtual unenhanced images of 70 lesions (97.2%) and true unenhanced images of 72 lesions (100%) were judged acceptable (p = 0.5). The mean quality score of virtual unenhanced images was 2.0 +/- 0.7 and of true unenhanced images was 1.5 +/- 0.5 (p < 0.001). Mean contrast enhancement measured on true unenhanced and blended weighted-average images was 45.9 +/- 15.9 HU (range, 21-78 HU) and on color-coded iodine overlay images was 47.3 +/- 16.8 HU (range, 22-75 HU) with no significant differences. Enhancement was excluded on color-coded iodine overlay images with a significantly (p < 0.03) higher level of confidence than it was on true unenhanced and blended weighted-average images. The mean dose reduction with use of a combined dual-and single-energy dual-phase CT protocol was 29.1% +/- 11.9% (p < 0.001). CONCLUSION. Dual-source dual-energy CT is a reliable imaging technique in the evaluation of complex cystic renal masses. True unenhanced images can be replaced by virtual unenhanced images with considerable radiation dose reduction. The color-coded iodine overlay technique is a useful tool for both excluding and identifying endocystic enhancement.
引用
收藏
页码:1026 / 1034
页数:9
相关论文
共 37 条
[1]
Complex cystic renal masses: Characterization with contrast-enhanced US [J].
Ascenti, Giorgio ;
Mazziotti, Silvio ;
Zimbaro, Giovanni ;
Settineri, Nicola ;
Magno, Carlo ;
Melloni, Darwin ;
Caruso, Rosario ;
Scribano, Emanuele .
RADIOLOGY, 2007, 243 (01) :158-165
[2]
Dual-Energy CT for Detection of Endoleaks After Endovascular Abdominal Aneurysm Repair: Usefulness of Colored Iodine Overlay [J].
Ascenti, Giorgio ;
Mazziotti, Silvio ;
Lamberto, Salvatore ;
Bottari, Antonio ;
Caloggero, Simona ;
Racchiusa, Sergio ;
Mileto, Achille ;
Scribano, Emanuele .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) :1408-1414
[3]
Stone-Targeted Dual-Energy CT: A New Diagnostic Approach to Urinary Calculosis [J].
Ascenti, Giorgio ;
Siragusa, Carmelo ;
Racchiusa, Sergio ;
Ielo, Isidora ;
Privitera, Giambattista ;
Midili, Federica ;
Mazziotti, Silvio .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (04) :953-958
[4]
Renal cyst pseudoenhancement: Evaluation with an anthropomorphic body CT phantom [J].
Birnbaum, BA ;
Maki, DD ;
Chakraborty, DP ;
Jacobs, JE ;
Babb, JS .
RADIOLOGY, 2002, 225 (01) :83-90
[5]
Renal cyst pseudoenhancement: Influence of multidetector CT reconstruction algorithm and scanner type in phantom model [J].
Birnbaum, Bernard A. ;
Hindman, Nicole ;
Lee, Julie ;
Babb, James S. .
RADIOLOGY, 2007, 244 (03) :767-775
[6]
BOSNIAK MA, 1986, RADIOLOGY, V158, P1
[7]
Problems in the detection and characterization of small renal masses [J].
Bosniak, MA ;
Rofsky, NM .
RADIOLOGY, 1996, 200 (01) :286-287
[8]
Dual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: a phantom feasibility study [J].
Brown, C. L. ;
Hartman, R. P. ;
Dzyubak, O. P. ;
Takahashi, N. ;
Kawashima, A. ;
McCollough, C. H. ;
Bruesewitz, M. R. ;
Primak, A. M. ;
Fletcher, J. G. .
EUROPEAN RADIOLOGY, 2009, 19 (05) :1289-1295
[9]
Abdominal Aorta: Evaluation with Dual-Source Dual-Energy Multidetector CT after Endovascular Repair of Aneurysms-Initial Observations [J].
Chandarana, Hersh ;
Godoy, Myrna C. B. ;
Vlahos, Ioannis ;
Graser, Anno ;
Babb, James ;
Leidecker, Christianne ;
Macari, Michael .
RADIOLOGY, 2008, 249 (02) :692-700
[10]
Iodine Quantification With Dual-Energy CT: Phantom Study and Preliminary Experience With Renal Masses [J].
Chandarana, Hersh ;
Megibow, Alec J. ;
Cohen, Benjamin A. ;
Srinivasan, Ramya ;
Kim, Danny ;
Leidecker, Christianne ;
Macari, Michael .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) :W693-W700