Dual-Energy CT for Detection of Endoleaks After Endovascular Abdominal Aneurysm Repair: Usefulness of Colored Iodine Overlay

被引:67
作者
Ascenti, Giorgio [1 ]
Mazziotti, Silvio [1 ]
Lamberto, Salvatore [1 ]
Bottari, Antonio [1 ]
Caloggero, Simona [1 ]
Racchiusa, Sergio [1 ]
Mileto, Achille [1 ]
Scribano, Emanuele [1 ]
机构
[1] Univ Messina, Dept Radiol Sci, Policlin G Martino, I-98100 Messina, Italy
关键词
dual-energy CT; endoleak; endovascular aneurysm repair (EVAR); iodine overlay technique; virtual unenhanced images; AORTIC-ANEURYSM; MULTIDETECTOR CT; INITIAL-EXPERIENCE; DELAYED PHASE; HELICAL CT; FOLLOW-UP; ANGIOGRAPHY; ABDOMEN; CLASSIFICATION; MANAGEMENT;
D O I
10.2214/AJR.10.4505
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
OBJECTIVE. The purpose of our study was to evaluate the value of dual-source dual-energy CT with colored iodine overlay for detection of endoleaks after endovascular abdominal aortic aneurysm repair. We also calculated the potential dose reduction by using a dual-energy CT single-phase protocol. SUBJECTS AND METHODS. From November 2007 to November 2009, 74 patients underwent CT angiography 2-7 days after endovascular repair during single-energy unenhanced and dual-energy venous phases. By using dual-energy software, the iodine overlay was superimposed on venous phase images with different percentages ranging between 0 (virtual unenhanced images) and 50-75% to show the iodine in an orange color. Two blinded readers evaluated the data for diagnosis of endoleaks during standard unenhanced and venous phase images (session 1, standard of reference) and virtual unenhanced and venous phase images with colored iodine overlay images (session 2). We compared the effective dose radiation of a single-energy biphasic protocol with that of a single-phase dual-energy protocol. The diagnostic accuracy of session 2 was calculated. RESULTS. The mean dual-energy effective dose was 7.27 mSv. By using a dual-energy single-phase protocol, we obtained a mean dose reduction of 28% with respect to a single-energy biphasic protocol. The diagnostic accuracy of session 2 was: 100% sensitivity, 100% specificity, 100% negative predictive value, and 100% positive predictive value. Statistically significant differences in the level of confidence for endoleak detection between the two sessions were found by reviewers for scores 3-5. CONCLUSION. Dual-energy CT with colored iodine overlay is a useful diagnostic tool in endoleak detection. The use of a dual-energy single-phase study protocol will lower radiation exposure to patients.
引用
收藏
页码:1408 / 1414
页数:7
相关论文
共 35 条
[1]
Multidetector CT in abdominal aortic aneurysm following endovascular repair: How to consider the value of a delayed phase [J].
Abada, Hicham T. ;
Golzarian, Jafar .
RADIOLOGY, 2007, 245 (02) :610-610
[2]
Endoleaks After Endovascular Abdominal Aortic Aneurysm Repair: Management Strategies According to CT Findings [J].
Bashir, Mustafa R. ;
Ferral, Hector ;
Jacobs, Chad ;
McCarthy, Walter ;
Goldin, Marshall .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) :W178-W186
[3]
Dual-Energy CT for the Assessment of Chronic Myocardial Infarction in Patients With Chronic Coronary Artery Disease: Comparison With 3-T MRI [J].
Bauer, Ralf W. ;
Kerl, J. Matthias ;
Fischer, Nadine ;
Burkhard, Thorsten ;
Larson, Maya C. ;
Ackermann, Hanns ;
Vogl, Thomas J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) :639-646
[4]
Endovascular versus open surgical elective repair of infrarenal abdominal aortic aneurysm: Predictors of patient discharge destination [J].
Bosch, JL ;
Beinfeld, MT ;
Halpern, EF ;
Lester, JS ;
Gazelle, GS .
RADIOLOGY, 2001, 220 (03) :576-580
[5]
Dual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: a phantom feasibility study [J].
Brown, C. L. ;
Hartman, R. P. ;
Dzyubak, O. P. ;
Takahashi, N. ;
Kawashima, A. ;
McCollough, C. H. ;
Bruesewitz, M. R. ;
Primak, A. M. ;
Fletcher, J. G. .
EUROPEAN RADIOLOGY, 2009, 19 (05) :1289-1295
[6]
Clinical Utility of Dual-Energy CT in the Evaluation of Solitary Pulmonary Nodules: Initial Experience [J].
Chae, Eun Jin ;
Song, Jae-Woo ;
Seo, Joon Beom ;
Krauss, Bernhard ;
Jang, Yu Mi ;
Song, Koun-Sik .
RADIOLOGY, 2008, 249 (02) :671-681
[7]
Abdominal Aorta: Evaluation with Dual-Source Dual-Energy Multidetector CT after Endovascular Repair of Aneurysms-Initial Observations [J].
Chandarana, Hersh ;
Godoy, Myrna C. B. ;
Vlahos, Ioannis ;
Graser, Anno ;
Babb, James ;
Leidecker, Christianne ;
Macari, Michael .
RADIOLOGY, 2008, 249 (02) :692-700
[8]
The assessment of intracranial bleeding with virtual unenhanced imaging by means of dual-energy CT angiography [J].
Ferda, Jiri ;
Novak, Milan ;
Mirka, Hynek ;
Baxa, Jan ;
Ferdova, Eva ;
Bednarova, Alena ;
Flohr, Thomas ;
Schmidt, Bernhard ;
Klotz, Ernst ;
Kreuzberg, Boris .
EUROPEAN RADIOLOGY, 2009, 19 (10) :2518-2522
[9]
Dual-Energy and Dual-Source CT: Is There a Role in the Abdomen and Pelvis? [J].
Fletcher, Joel G. ;
Takahashi, Naoki ;
Hartman, Robert ;
Guimaraes, Luis ;
Huprich, James E. ;
Hough, David M. ;
Yu, Lifeng ;
McCollough, Cynthia H. .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (01) :41-+
[10]
Evaluation of abdominal aortic aneurysm after endoluminal treatment: Comparison of color Doppler sonography with biphasic helical CT [J].
Golzarian, J ;
Murgo, S ;
Dussaussois, L ;
Guyot, S ;
Said, KA ;
Wautrecht, JC ;
Struyven, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (03) :623-628