摘要
The purpose of this study was to assess virtual unenhanced brain computed tomography (CT) images obtained by dual-energy CT angiography (CTA) for the detection of intracranial bleeding. In total, 25 patients were included in the study (average age 53.2 years, range 2575 years, 14 male, 11 female), all with intracranial bleeding on unenhanced brain CT and who underwent additional CTA performed on a dual-source CT in a dual-energy acquisition mode. The two X-ray tubes were operated at 140 and 80 kV, respectively. Data were analyzed using dual-energy evaluation software. Virtual unenhanced images were calculated by removing the relative iodine content from each voxel. The virtual unenhanced images were evaluated by a radiologist blinded to the findings of the conventional images related to the presence of Intracranial bleeding. The image quality and contrast-to-noise ratio (CNR) between bleeding and brain tissue were assessed. The virtual image quality was found to be sufficient in 96%. The agreement in detection of intracranial bleeding on virtual and conventional unenhanced images reached 96% in per-lesion analysis and 100% in per-patient analysis. The averaged CNR reached 2.63 in virtual unenhanced images and 3.27 in conventional. Virtual unenhanced images are sufficient for the detection of intracranial bleeding.
引用
收藏
页码:2518 / 2522
页数:5
相关论文
共 10 条
  • [1] Acute subarachnoid hemorrhage: using 64-slice multidetector CT angiography to "triage" patients' treatment
    Agid, R.
    Lee, S. K.
    Willinsky, R. A.
    Farb, R. I.
    terBrugge, K. G.
    [J]. NEURORADIOLOGY, 2006, 48 (11) : 787 - 794
  • [2] TRANSIENT MONOCULAR VISUAL-LOSS (TMVL) - 60 CONSECUTIVE PATIENTS
    BRUNO, A
    CORBETT, J
    BILLER, J
    ADAMS, H
    [J]. STROKE, 1988, 19 (01) : 135 - 135
  • [3] Clinical Utility of Dual-Energy CT in the Evaluation of Solitary Pulmonary Nodules: Initial Experience
    Chae, Eun Jin
    Song, Jae-Woo
    Seo, Joon Beom
    Krauss, Bernhard
    Jang, Yu Mi
    Song, Koun-Sik
    [J]. RADIOLOGY, 2008, 249 (02) : 671 - 681
  • [4] FERDA J, 2008, CES RADIOL, V62, P277
  • [5] Ferda J, 2008, CES RADIOL, V62, P11
  • [6] Material differentiation by dual energy CT: initial experience
    Johnson, Thorsten R. C.
    Krauss, Bernhard
    Sedlmair, Martin
    Grasruck, Michael
    Bruder, Herbert
    Morhard, Dominik
    Fink, Christian
    Weckbach, Sabine
    Lenhard, Miriam
    Schmidt, Bernhard
    Flohr, Thomas
    Reiser, Maximilian F.
    Becker, Christoph R.
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (06) : 1510 - 1517
  • [7] EVALUATION OF CEREBRAL ANEURYSMS WITH HELICAL CT - CORRELATION WITH CONVENTIONAL ANGIOGRAPHY AND MR-ANGIOGRAPHY
    SCHWARTZ, RB
    TICE, HM
    HOOTEN, SM
    HSU, LG
    STIEG, PE
    [J]. RADIOLOGY, 1994, 192 (03) : 717 - 722
  • [8] Endoleaks after Endovascular Abdominal Aortic Aneurysm Repair: Detection with Dual-Energy Dual-Source CT
    Stolzmann, Paul
    Frauenfelder, Thomas
    Pfammatter, Thomas
    Peter, Nicole
    Scheffel, Hans
    Lachat, Mario
    Schmidt, Bernhard
    Marincek, Borut
    Alkadhi, Hatem
    Schertler, Thomas
    [J]. RADIOLOGY, 2008, 249 (02) : 682 - 691
  • [9] Dual energy CT for the assessment of lung perfusion-Correlation to scintigraphy
    Thieme, Sven F.
    Becker, Christoph R.
    Hacker, Marcus
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Johnson, Thorsten R. C.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) : 369 - 374
  • [10] Multislice CT angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling
    Westerlaan, H. E.
    Gravendeel, J.
    Fiore, D.
    Metzemaekers, J. D. M.
    Groen, R. J. M.
    Mooij, J. J. A.
    Oudkerk, M.
    [J]. NEURORADIOLOGY, 2007, 49 (12) : 997 - 1007