Ratiometric Electrochemical Sensor for Effective and Reliable Detection of Ascorbic Acid in Living Brains

被引:138
作者
Cheng, Hanjun [1 ]
Wang, Xiaoyu [1 ]
Wei, Hui [1 ]
机构
[1] Nanjing Univ, Dept Biomed Engn, Coll Engn & Appl Sci, Collaborat Innovat Ctr Chem Life Sci,Nanjing Natl, Nanjing 210093, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
IN-VIVO; RAT-BRAIN; ELECTRON-TRANSFER; CELL; BIOSENSOR; MICROELECTRODES; VOLTAMMETRY; GENERATION; STRIATUM; TINNITUS;
D O I
10.1021/acs.analchem.5b02014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The in vivo detection of ascorbic acid (AA), one of the physiologically important cerebral neurochemicals, is critical to probe and understand brain functions. Electrochemical sensors are convenient for AA detection. However, conventional electrochemical sensors usually suffer from several challenges, such as sluggish electron transfer kinetics for AA oxidation and poor reproducibility. To address these challenges, here we report ratiometric electrochemical sensors for effective and reliable detection of AA in living brains. The sensors were constructed by immobilizing preassembled thionine/Ketjen black (KB) nanocomposites onto glassy carbon (GC) electrodes or carbon fiber microelectrodes (CFMEs). The KB in the rationally functionalized nanocomposites efficiently facilitated AA oxidation at a relatively negative potential (similar to-0.14 V) without particular physical or chemical pretreatment, forming the basis of selective measurement of AA. With a well-defined and reversible pair of redox wave at -0.22 V, the assembled thionine acted as an internal reference to substantially alleviate the lab-to-lab, person-to-person, and electrode-to-electrode variations. The in vitro experiments demonstrated that the sensors exhibited extremely high reproducibility and stability toward selective measurement of AA. More, with operational simplicity and robustness in analytical performance, the designed sensors were successfully applied to in vivo effectively, selectively, and reliably monitor the dynamic change of cerebral AA associated with pathological processes (i.e., salicylate-induced tinnitus as the model) in living rats' brains. This study not only offers a new strategy for construction of ratiometric electrochemical sensors but also opens a new way for selective and reliable detection of neurochemicals for probing brain functions.
引用
收藏
页码:8889 / 8895
页数:7
相关论文
共 37 条
[1]   A failure in energy metabolism and antioxidant uptake precede symptoms of Huntington's disease in mice [J].
Acuna, Anibal I. ;
Esparza, Magdalena ;
Kramm, Carlos ;
Beltran, Felipe A. ;
Parra, Alejandra V. ;
Cepeda, Carlos ;
Toro, Carlos A. ;
Vidal, Rene L. ;
Hetz, Claudio ;
Concha, Ilona I. ;
Brauchi, Sebastian ;
Levine, Michael S. ;
Castro, Maite A. .
NATURE COMMUNICATIONS, 2013, 4
[2]   Vitamin C induces Tet-dependent DNA demethylation and a blastocyst-like state in ES cells [J].
Blaschke, Kathryn ;
Ebata, Kevin T. ;
Karimi, Mohammad M. ;
Zepeda-Martinez, Jorge A. ;
Goyal, Preeti ;
Mahapatra, Sahasransu ;
Tam, Angela ;
Laird, Diana J. ;
Hirst, Martin ;
Rao, Anjana ;
Lorincz, Matthew C. ;
Ramalho-Santos, Miguel .
NATURE, 2013, 500 (7461) :222-+
[3]   A Two-Channel Ratiometric Electrochemical Biosensor for InVivo Monitoring of Copper Ions in a Rat Brain Using Gold Truncated Octahedral Microcages [J].
Chai, Xiaolan ;
Zhou, Xinguang ;
Zhu, Anwei ;
Zhang, Limin ;
Qin, Yao ;
Shi, Guoyue ;
Tian, Yang .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2013, 52 (31) :8129-8133
[4]   A facile method to prepare stable noncovalent functionalized graphene solution with thionine [J].
Chen, Cao ;
Zhai, Wentao ;
Lu, Dingding ;
Zhang, Haobin ;
Zheng, Wenge .
MATERIALS RESEARCH BULLETIN, 2011, 46 (04) :583-587
[5]   Carbon Nanotube-Bilirubin Oxidase Bioconjugate as a New Biofuel Cell Label for Self-Powered Immunosensor [J].
Cheng, Jiashun ;
Han, Yajing ;
Deng, Liu ;
Guo, Shaojun .
ANALYTICAL CHEMISTRY, 2014, 86 (23) :11782-11788
[6]   Integrated Self-Powered Microchip Biosensor for Endogenous Biological Cyanide [J].
Deng, Liu ;
Chen, Chaogui ;
Zhou, Ming ;
Guo, Shaojun ;
Wang, Erkang ;
Dong, Shaojun .
ANALYTICAL CHEMISTRY, 2010, 82 (10) :4283-4287
[7]   Reagentless, Ratiometric Electrochemical DNA Sensors with Improved Robustness and Reproducibility [J].
Du, Yan ;
Lim, Byung Joon ;
Li, Bingling ;
Jiang, Yu Sherry ;
Sessler, Jonathan L. ;
Ellington, Andrew D. .
ANALYTICAL CHEMISTRY, 2014, 86 (15) :8010-8016
[8]   The neuroscience of tinnitus [J].
Eggermont, JJ ;
Roberts, LE .
TRENDS IN NEUROSCIENCES, 2004, 27 (11) :676-682
[9]   VOLTAMMETRY IN THE STRIATUM OF CHRONIC FREELY MOVING RATS - DETECTION OF CATECHOLS AND ASCORBIC-ACID [J].
GONON, F ;
BUDA, M ;
CESPUGLIO, R ;
JOUVET, M ;
PUJOL, JF .
BRAIN RESEARCH, 1981, 223 (01) :69-80
[10]   Fabrication of bienzyme nanobiocomposite electrode using functionalized carbon nanotubes for biosensing applications [J].
Jeykumari, D. R. Shobha ;
Narayanan, S. Sriman .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (11) :1686-1693