Shielding, but not zeroing of the ambient magnetic field reduces stress-induced analgesia in mice

被引:52
作者
Choleris, E
Del Seppia, C
Thomas, AW
Luschi, P
Ghione, S
Moran, GR
Prato, FS
机构
[1] St Josephs Hlth Ctr, Lawson Hlth Res Inst, London, ON N6A 4V2, Canada
[2] Univ Western Ontario, London, ON N6A 4V2, Canada
[3] CNR, Inst Clin Physiol, I-56126 Pisa, Italy
[4] St Josephs Hlth Care, Dept Nucl Med & Magnet Resonance, Lawson Hlth Res Inst, London, ON N6A 4L6, Canada
[5] Univ Western Ontario, London, ON N6A 4L6, Canada
[6] Univ Pisa, Dept Ecol Ethol & Evolut, I-56126 Pisa, Italy
关键词
near-zero magnetic fields; nociception; stress-induced analgesia;
D O I
10.1098/rspb.2001.1866
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Magnetic field exposure was consistently found to affect pain inhibition (i.e. analgesia). Recently, we showed that an extreme reduction of the ambient magnetic and electric environment, by mu-metal shielding, also affected stress-induced analgesia (SIA) in C57 mice. Using CD1 mice, we report here the same findings from replication studies performed independently in Pisa, Italy and London, ON, Canada. Also, neither selective vector nulling of the static component of the ambient magnetic field with Helmholtz coils, nor copper shielding of only the ambient electric field, affected SIA in mice. We further show that a pre-stress exposure to the mu-metal box is necessary for the anti-analgesic effects to occur. The differential effects of the two near-zero magnetic conditions may depend on the elimination (obtained only by mu-metal shielding) of the extremely weak time-varying component of the magnetic environment. This would provide the first direct and repeatable evidence for a behavioural and physiological effect of very weak time-varying magnetic fields, suggesting the existence of a very sensitive magnetic discrimination in the endogenous mechanisms that underlie SIA. This has important implications for other reported effects of exposures to very weak magnetic fields and for the theoretical work that considers the mechanisms underlying the biological detection of weak magnetic fields.
引用
收藏
页码:193 / 201
页数:9
相关论文
共 68 条
[61]   Magnetic field exposure and behavioral monitoring system [J].
Thomas, AW ;
Drost, DJ ;
Prato, FS .
BIOELECTROMAGNETICS, 2001, 22 (06) :401-407
[62]  
Tipping DR, 1999, BIOELECTROMAGNETICS, V20, P129, DOI 10.1002/(SICI)1521-186X(1999)20:2<129::AID-BEM8>3.0.CO
[63]  
2-Q
[64]   Weak combined magnetic field affects basic and morphine-induced rat's EEG [J].
Vorobyov, VV ;
Sosunov, EA ;
Kukushkin, NI ;
Lednev, VV .
BRAIN RESEARCH, 1998, 781 (1-2) :182-187
[65]   Structure and function of the vertebrate magnetic sense [J].
Walker, MM ;
Diebel, CE ;
Haugh, CV ;
Pankhurst, PM ;
Montgomery, JC ;
Green, CR .
NATURE, 1997, 390 (6658) :371-376
[66]   THE RESPONSE OF LIVING CELLS TO VERY WEAK ELECTRIC-FIELDS - THE THERMAL NOISE LIMIT [J].
WEAVER, JC ;
ASTUMIAN, RD .
SCIENCE, 1990, 247 (4941) :459-462
[67]   BIOEFFECTS OF HIGH MAGNETIC-FIELDS - A STUDY USING A SIMPLE ANIMAL-MODEL [J].
WEISS, J ;
HERRICK, RC ;
TABER, KH ;
CONTANT, C ;
PLISHKER, GA .
MAGNETIC RESONANCE IMAGING, 1992, 10 (04) :689-694
[68]  
Wiltschko R., 1995, MAGNETIC ORIENTATION, P1