Deformation of press-fitted metallic resurfacing cups. Part 1: experimental simulation

被引:86
作者
Jin, ZM [1 ]
Meakins, S
Morlock, MM
Parsons, P
Hardaker, C
Flett, M
Isaac, G
机构
[1] Univ Leeds, Sch Mech Engn, Leeds LS2 9JT, W Yorkshire, England
[2] DePuy Int Ltd, Leeds, W Yorkshire, England
[3] Tech Univ Hamburg, Biomech Sect, D-2100 Hamburg, Germany
关键词
metal-on-metal articulations; hip resurface; cup deformation;
D O I
10.1243/095441105X69150
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The interference press fit of a metallic one-piece acetabular cup employed for metal-on-metal hip resurfacing procedures was investigated experimentally under laboratory conditions in the present study, in particular regarding the cup deformation. Tests were carried out in cadavers as well as polyurethane foams of various grades with different elastic moduli to represent different cancellous bone qualities. The cadaver test was used to establish the most suitable configuration of the foam model representing realistic support and geometrical conditions at the pelvis. It was found that a spherical cavity, with two identical areas relieved on opposite sides, was capable of creating a two-point pinching action of the ischeal and ilial columns on the cup as the worst-case scenario. Furthermore, the cup deformation produced from such a two-point loading model with a grade 30 foam was similar to that measured from the cadaver test. Therefore, such a protocol was employed in subsequent experimental tests. For a given size of the outside diameter of the cup of 60 mm, the cup deflection was shown to be dependent largely on the cup wall thickness and the diametral interference between cup and prepared cavity at implantation. For a relatively thin cup with a wall thickness between 2.3 mm (equator) and 4 mm (pole) and with a modest nominal diametral interference of 1 mm, which corresponds to an actual interference of approximately 0.5 mm, the maximum diametral cup deflection (at the rim) was around 60 mu m, compared with a diametral clearance of 80-120 mu m between the femoral head and the acetabular cup, generally required for fluid-film lubrication and tribological performances. Stiffening of the cup, by both thickening and lateralizing by 1 mm, reduced the cup deformation to between 30 and 50 mu m with actual diametral interferences between 0.5 and 1 mm.
引用
收藏
页码:299 / 309
页数:11
相关论文
共 22 条
[1]
Metal-on-metal hybrid surface arthroplasty:: Two to six-year follow-up study [J].
Amstutz, HC ;
Beaulé, PE ;
Dorey, FJ ;
Le Duff, MJ ;
Campbell, PA ;
Gruen, TA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (01) :28-39
[2]
Amstutz HC, 1998, HIP INT, V8-4, P187
[3]
Initial stability of a cementless acetabular cup design: Experimental investigation on the effect of adding fins to the rim of the cup [J].
Baleani, M ;
Fognani, R ;
Toni, A .
ARTIFICIAL ORGANS, 2001, 25 (08) :664-669
[4]
Metal-on-metal surface arthroplasty with a cemented femoral component -: A 7-10 year follow-up study [J].
Beaulé, PE ;
Le Duff, M ;
Campbell, P ;
Dorey, FJ ;
Park, SH ;
Amstutz, HC .
JOURNAL OF ARTHROPLASTY, 2004, 19 (08) :17-22
[5]
Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis [J].
Daniel, J ;
Pynsent, PB ;
McMinn, DJW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (02) :177-184
[6]
A hip joint simulator study of the performance of metal-on-metal joints - Part II: Design [J].
Dowson, D ;
Hardaker, C ;
Flett, M ;
Isaac, GH .
JOURNAL OF ARTHROPLASTY, 2004, 19 (08) :124-130
[7]
A hip joint simulator study of the performance of metal-on-metal joints - Part I: The role of materials [J].
Dowson, D ;
Hardaker, C ;
Flett, M ;
Isaac, GH .
JOURNAL OF ARTHROPLASTY, 2004, 19 (08) :118-123
[8]
Metal-on-metal hip resurfacing [J].
Ebied, A ;
Journeaux, S .
CURRENT ORTHOPAEDICS, 2002, 16 (06) :420-425
[9]
Farrar MB, 1997, TRANSE ORTHOP RES SO, V43, P764
[10]
HOWIE DW, 1993, ORTHOP CLIN N AM, V24, P571