Gas-pressure-driven stepwise-gradient elution system for microcolumn liquid chromatography

被引:3
作者
Takeuchi, T [1 ]
Lim, LW [1 ]
机构
[1] Gifu Univ, Fac Engn, Dept Chem, Gifu 5011193, Japan
关键词
gas-pressure-driven flow; stepwise-gradient elution; postcolumn-controlled flow system; microcolumn liquid chromatography;
D O I
10.2116/bunsekikagaku.50.825
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Stepwise-gradient elution was carried out with a gas-pressure-driven flow system. The system was assembled from a gas cylinder, a 6-way selection valve, an injection valve (or a sample-enrichment system), a separation column, a UV detector and a syringe pump. Eluents with different compositions were supplied by pressure applied from an argon gas cylinder; switching the 6-way selection valve changed the eluent composition. The syringe pump located downstream of the detector regulated the flow rate of the eluent. The relative standard deviation of the retention time was 0.4-0.6% for isocratic elution as well as for two-step gradient elution. The system was applied to die separation of phthalates and alkylbenzenes.
引用
收藏
页码:825 / 828
页数:4
相关论文
共 12 条
[1]   Evaluation of automated isocratic and gradient nano-liquid chromatography and capillary electrochromatography [J].
Alexander, JN ;
Poli, JB ;
Markides, KE .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2398-2409
[2]   Nanoflow solvent gradient delivery from a microfabricated device for protein identifications by electrospray ionization mass spectrometry [J].
Figeys, D ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3721-3727
[3]   Capillary electrochromatography with gradient elution [J].
Huber, CG ;
Choudhary, G ;
Horvath, C .
ANALYTICAL CHEMISTRY, 1997, 69 (21) :4429-4436
[4]   Solvent-programmed microchip open-channel electrochromatography [J].
Kutter, JP ;
Jacobson, SC ;
Matsubara, N ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (15) :3291-3297
[5]   Gradient elution electrochromatography with a flow-injection analysis interface [J].
Lister, AS ;
Rimmer, CA ;
Dorsey, JG .
JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) :105-112
[6]   STEPWISE GRADIENT ELUTION USING SWITCHING VALVES IN MICRO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
TAKEUCHI, T ;
NIWA, T ;
ISHII, D .
JOURNAL OF CHROMATOGRAPHY, 1987, 405 :117-124
[7]   HIGH-BACK-PRESSURE LIQUID-CHROMATOGRAPHY .2. DEVELOPMENT OF A POST-COLUMN-CONTROLLED FLOW SYSTEM [J].
TAKEUCHI, T ;
ISHII, D .
JOURNAL OF CHROMATOGRAPHY, 1982, 239 (APR) :633-641
[8]  
TAKEUCHI T, 1981, J CHROMATOGR, V213, P25, DOI 10.1016/S0021-9673(00)80628-7
[9]   Analysis of corticosteroids in biofluids by capillary electrochromatography with gradient elution [J].
Taylor, MR ;
Teale, P ;
Westwood, SA ;
Perrett, D .
ANALYTICAL CHEMISTRY, 1997, 69 (13) :2554-2558
[10]   Gradient capillary electrochromatography of drug mixtures with UV and electrospray ionisation mass spectrometric detection [J].
Taylor, MR ;
Teale, P .
JOURNAL OF CHROMATOGRAPHY A, 1997, 768 (01) :89-95