Gradient elution electrochromatography with a flow-injection analysis interface

被引:34
作者
Lister, AS [1 ]
Rimmer, CA [1 ]
Dorsey, JG [1 ]
机构
[1] Florida State Univ, Dept Chem, Tallahassee, FL 32306 USA
关键词
electrochromatography; flow injection analysis; electroosmotic flow; gradient elution; polynuclear aromatic hydrocarbons;
D O I
10.1016/S0021-9673(98)00682-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A flow-injection analysis-capillary electrochromatography interface is used for gradient elution capillary electrochromatography giving purely electroosmotic flow through the analytical column. Solvent gradients were generated with a micro-LC system connected to the interface. Injections were carried out on-line using an inert rotary LC valve controlled by an electric actuator. Gradient shape was measured from acetonitrile (5% acetone)-water (50:50, v/v) to (100:0) in open tubular experiments. When compared to conventional instrumentation, peak tailing and peak width increased slightly using the interface. A test mixture of nine solutes was evaluated in isocratic and gradient elution modes. Using the interface, a gradient of MeCN-water (60:40) to (90:10) provided baseline separation of all nine solutes in under 18 min with good band spacing. Reproducibility of retention times in eight replicate injections was found to be better than 2% R.S.D. for all solutes. This interface also allows use of autoinjectors and dramatically lessens movement of the packed column, improving column lifetime. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:105 / 112
页数:8
相关论文
共 23 条
[1]   EVALUATION OF THE PARAMETERS DETERMINING THE PERFORMANCE OF ELECTROCHROMATOGRAPHY IN PACKED CAPILLARY COLUMNS [J].
BEHNKE, B ;
GROM, E ;
BAYER, E .
JOURNAL OF CHROMATOGRAPHY A, 1995, 716 (1-2) :207-213
[2]   PRESSURIZED GRADIENT ELECTRO-HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BEHNKE, B ;
BAYER, E .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (01) :93-98
[3]   CAPILLARY ELECTROCHROMATOGRAPHY - SOME IMPORTANT CONSIDERATIONS IN THE PREPARATION OF PACKED CAPILLARIES AND THE CHOICE OF MOBILE-PHASE BUFFERS [J].
BOUGHTFLOWER, RJ ;
UNDERWOOD, T ;
PATERSON, CJ .
CHROMATOGRAPHIA, 1995, 40 (5-6) :329-335
[4]   REDUCTION OF REEQUILIBRATION TIME FOLLOWING GRADIENT ELUTION REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
COLE, LA ;
DORSEY, JG .
ANALYTICAL CHEMISTRY, 1990, 62 (01) :16-21
[5]   Advances in capillary electrochromatography [J].
Colón, LA ;
Reynolds, KJ ;
Alicea-Maldonado, R ;
Fermier, AM .
ELECTROPHORESIS, 1997, 18 (12-13) :2162-2174
[6]   Capillary electrochromatography [J].
Colon, LA ;
Guo, Y ;
Fermier, A .
ANALYTICAL CHEMISTRY, 1997, 69 (15) :A461-A467
[7]   Electrochromatography [J].
Crego, AL ;
Gonzalez, A ;
Marina, ML .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1996, 26 (04) :261-304
[8]   PRESSURIZED FLOW ELECTROCHROMATOGRAPHY WITH REVERSED-PHASE CAPILLARY COLUMNS [J].
EIMER, T ;
UNGER, KK ;
TSUDA, T .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (7-8) :649-653
[9]   Step-gradient capillary electrochromatography [J].
Euerby, MR ;
Gilligan, D ;
Johnson, CM ;
Bartle, KD .
ANALYST, 1997, 122 (10) :1087-1088
[10]   Capillary electrochromatography with gradient elution [J].
Huber, CG ;
Choudhary, G ;
Horvath, C .
ANALYTICAL CHEMISTRY, 1997, 69 (21) :4429-4436