Accuracy of 16-slice multi-detector CT to quantify the degree of coronary artery stenosis: Assessment of cross-sectional and longitudinal vessel reconstructions

被引:40
作者
Cury, RC
Ferencik, M
Achenbach, S
Pomerantsev, E
Nieman, K
Moselewski, F
Abbara, S
Jang, IK
Brady, TJ
Hoffmann, U
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiol, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Div Cardiol, Boston, MA 02114 USA
[3] Univ Erlangen Nurnberg, Dept Internal Med 2, D-8520 Erlangen, Germany
关键词
computed tomography; atherosclerosis; coronary artery disease;
D O I
10.1016/j.ejrad.2005.12.019
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Sixteen-slice multi-detector computed tomography (MDCT) permits reliable noninvasive detection of significant coronary stenosis based on qualitative visual assessment. The purpose of this study was to determine the accuracy of MDCT to quantify the degree of coronary stenosis as compared to quantitative coronary angiography (QCA) using two different reconstruction methods. Methods: We studied 69 coronary artery lesions from 38 consecutive patients that underwent 16-slice MDCT as a part of research study; which enrolled consecutive subjects scheduled for clinically indicated invasive coronary angiography. Nine coronary artery lesions with motion artifacts, heavily calcified plaques or stents were excluded from the analysis. The degree of stenosis was calculated by two independent readers non-blinded to the location of the stenosis, but blinded to the results of the QCA. MDCT luminal diameters were measured in cross-sectional multi-planar reformatted (CS-MPR) images created perpendicular to the centerline of the vessel and in 5 mm thin-slab maximum intensity projections (MIP) parallel to the long axis of the vessel. Both MDCT methods were compared against QCA. Results: The mean degree of stenosis as measured by MDCT was closely correlated to QCA for both methods (CS-MPR versus QCA: 61 +/- 23% versus 64 +/- 29%; r(2) = 0.83, p < 0.001 and MIP versus QCA: 64 +/- 22% versus 64 +/- 29%; r(2) = 0.84, p < 0.001 for MIP. Bland-Altman analysis demonstrated a negative bias of the degree of stenosis of -2.8 +/- 12% using CS-MPR and a minimally positive bias of 0.6 +/- 12% for MIP. In stratified analysis for lesion severity (mild, 0-40%; moderate, 41-70% or severe, >70%) the agreement between both CS-MPR and MIP was high when compared to QCA (kappa = 0.74 and 0.71, respectively). Conclusion: Multi-detector spiral CT permits accurate quantitative assessment of the degree of coronary stenosis in selected data sets of sufficient quality using both cross-sectional and longitudinal vessel reconstructions. (C) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:345 / 350
页数:6
相关论文
共 16 条
[1]   Comparison of the degree of coronary stenoses by multidetector computed tomography versus by quantitative coronary angiography [J].
Cury, RC ;
Pomerantsev, EV ;
Ferencik, M ;
Hoffmann, U ;
Nieman, K ;
Moselewski, F ;
Abbara, S ;
Jang, IK ;
Brady, TJ ;
Achenbach, S .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (06) :784-787
[2]   Coronary artery: Quantitative evaluation of normal diameter determined with electron-beam CT compared with cine coronary angiography - Initial experience [J].
Funabashi, N ;
Kobayashi, Y ;
Perlroth, M ;
Rubin, GD .
RADIOLOGY, 2003, 226 (01) :263-271
[3]   Noninvasive coronary angiography with multislice computed tomography [J].
Hoffmann, MHK ;
Shi, HS ;
Schmitz, BL ;
Schmid, FT ;
Lieberknecht, ML ;
Schulze, R ;
Ludwig, B ;
Kroschel, U ;
Jahnke, N ;
Haerer, W ;
Brambs, HJ ;
Aschoff, AJ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (20) :2471-2478
[4]   Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease - Patient-versus segment-based analysis [J].
Hoffmann, U ;
Moselewski, F ;
Cury, RC ;
Ferencik, M ;
Jang, IK ;
Diaz, LJ ;
Abbara, S ;
Brady, TJ ;
Achenbach, S .
CIRCULATION, 2004, 110 (17) :2638-2643
[5]   Head-to-head comparison of three-dimensional navigator-gated magnetic resonance imaging and 16-slice computed tomography to detect coronary artery stenosis in patients [J].
Kefer, J ;
Coche, E ;
Legros, G ;
Pasquet, A ;
Grandin, C ;
Van Beers, BE ;
Vanoverschelde, JL ;
Gerber, BL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (01) :92-100
[6]   Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution [J].
Kuettner, A ;
Beck, T ;
Drosch, T ;
Kettering, K ;
Heuschmid, M ;
Burgstahler, C ;
Claussen, CD ;
Kopp, AF ;
Schroeder, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (01) :123-127
[7]   Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology - Initial clinical results [J].
Kuettner, A ;
Trabold, T ;
Schroeder, S ;
Feyer, A ;
Beck, T ;
Brueckner, A ;
Heuschmid, M ;
Burgstahler, C ;
Kopp, AF ;
Claussen, CD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (06) :1230-1237
[8]   Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography - A comparative study with quantitative coronary angiography and intravascular ultrasound [J].
Leber, AW ;
Knez, A ;
von Ziegler, F ;
Becker, A ;
Nikolaou, K ;
Paul, S ;
Wintersperger, B ;
Reiser, M ;
Becker, CR ;
Steinbeck, G ;
Boekstegers, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (01) :147-154
[9]   Effects of window and threshold levels on the accuracy of three-dimensional rendering techniques in coronary artery electron-beam CT angiography [J].
Lu, B ;
Dai, RP ;
Jiang, SL ;
Bal, H ;
He, S ;
Zhuang, N ;
Sun, XG ;
Budoff, MJ .
ACADEMIC RADIOLOGY, 2001, 8 (08) :754-761
[10]   Accuracy of thin-slice computed tomography in the detection of coronary stenoses [J].
Martuscelli, E ;
Romagnoli, A ;
D'Eliseo, A ;
Razzini, C ;
Tomassini, M ;
Sperandio, M ;
Simonetti, G ;
Romeo, F .
EUROPEAN HEART JOURNAL, 2004, 25 (12) :1043-1048