COMMISSIONING OF VOLUMETRIC MODULATED ARC THERAPY (VMAT)

被引:160
作者
Bedford, James L. [1 ]
Warrington, Alan P. [1 ]
机构
[1] Royal Marsden NHS Fdn Trust, Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2009年 / 73卷 / 02期
关键词
IMAT; VMAT; Arc therapy; IMRT; DMLC; RADIATION-THERAPY; COMMITTEE; IMRT;
D O I
10.1016/j.ijrobp.2008.08.055
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Volumetric modulated arc therapy (VMAT) involves the simultaneous use of dynamic multileaf collimator (DMLC) techniques and gantry arcing; appropriate quality assurance is therefore required. This article describes the development and implementation of procedures for commissioning VMAT on a commercial linear accelerator (Elekta PreciseBeam VMAT with MLCi and Beam Modulator heads). Materials and Methods: Tests for beam flatness and symmetry at the variable dose rates required for VMAT were performed. Multileaf collimator (MLC) calibration was investigated using dynamic prescriptions. The cumulative dose delivered by a sliding window aperture was measured and compared with calculated values. Rotational accuracy was evaluated using dynamic prescriptions which required accurate correlated motion of both gantry and MLC leaves. Finally, measured and calculated dose distributions for complete VMAT treatment plans were compared and evaluated. Results: Beam symmetry was found to be better than 3% down to dose rates of 75 MU/min. MLC calibration provided continuity of dose at match planes of better than 4%, which was comparable to interleaf leakage effects. Integrated sliding window doses were within 3% of those calculated. Tests for rotational accuracy showed uniformity of peripheral dose mostly within 4% of local control point dose, or approximately +/- 0.2% of total central dose. A two-arc prostate case showed an absolute dose difference between calculations and measurements of less than 3%, with gamma (3% and 3 mm) of better than 95%. Conclusions: VMAT has been successfully commissioned and has been introduced into clinical use. The Elekta DMLC has also been shown to be suitable for sliding window delivery. (C) 2009 Elsevier Inc.
引用
收藏
页码:537 / 545
页数:9
相关论文
共 10 条
[1]   Direct-aperture optimization applied to selection of beam orientations in intensity-modulated radiation therapy [J].
Bedford, J. L. ;
Webb, S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (02) :479-498
[2]   Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee [J].
Ezzell, GA ;
Galvin, JM ;
Low, D ;
Palta, JR ;
Rosen, I ;
Sharpe, MB ;
Xia, P ;
Xiao, Y ;
Xing, L ;
Yu, CX .
MEDICAL PHYSICS, 2003, 30 (08) :2089-2115
[3]  
Hall C., 2006, ACCEPTANCE TESTING C
[4]   Quality assurance of the dose delivered by small radiation segments [J].
Hansen, VN ;
Evans, PM ;
Budgell, GJ ;
Mott, JHL ;
Williams, PC ;
Brugmans, MJP ;
Wittkamper, FW ;
Mijnheer, BJ ;
Brown, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (09) :2665-2675
[5]   COMPREHENSIVE QA FOR RADIATION ONCOLOGY - REPORT OF AAPM RADIATION-THERAPY COMMITTEE TASK-GROUP-40 [J].
KUTCHER, GJ ;
COIA, L ;
GILLIN, M ;
HANSON, WF ;
LEIBEL, S ;
MORTON, RJ ;
PALTA, JR ;
PURDY, JA ;
REINSTEIN, LE ;
SVENSSON, GK ;
WELLER, M ;
WINGFIELD, L .
MEDICAL PHYSICS, 1994, 21 (04) :581-618
[6]   A technique for the quantitative evaluation of dose distributions [J].
Low, DA ;
Harms, WB ;
Mutic, S ;
Purdy, JA .
MEDICAL PHYSICS, 1998, 25 (05) :656-661
[7]   Volumetric modulated arc therapy: IMRT in a single gantry arc [J].
Otto, Karl .
MEDICAL PHYSICS, 2008, 35 (01) :310-317
[8]   Monitor unit settings for intensity modulated beams delivered using a step-and-shoot approach [J].
Sharpe, MB ;
Miller, BM ;
Yan, D ;
Wong, JW .
MEDICAL PHYSICS, 2000, 27 (12) :2719-2725
[9]   GENERATION OF ARBITRARY INTENSITY PROFILES BY DYNAMIC JAWS OR MULTILEAF COLLIMATORS [J].
SPIROU, SV ;
CHUI, CS .
MEDICAL PHYSICS, 1994, 21 (07) :1031-1041
[10]  
WEBB S, 2005, CONT IMRT DEV PHYS C