The snare-assisted technique for transcatheter coil occlusion of moderate to large patent ductus arteriosus: Immediate and intermediate results

被引:37
作者
Ing, FF
Sommer, RJ
机构
[1] Texas Childrens Hosp, Baylor Coll Med, Dept Pediat Cardiol, Houston, TX 77030 USA
[2] Mt Sinai Med Ctr, Mt Sinai Sch Med, Dept Pediat Cardiol, New York, NY USA
关键词
D O I
10.1016/S0735-1097(99)00058-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The purpose of this study was to evaluate the feasibility, safety and efficacy of using a snare-assisted technique to coil occlude the moderate to large size patent ductus arteriosus (PDA). BACKGROUND Transcatheter occlusion of small PDAs using Gianturco coils is safe and effective. However, in larger size PDAs and/or those with short PDA length, the procedure still carries risks of coil embolization, incomplete occlusion and failure to implant the coil. METHODS From January 1994 to June 1997 the records of 104 consecutive snare-assisted coil occlusions of moderate to large PDAs (minimum diameter >2.0 mm) were reviewed. Immediate and intermediate outcomes including complete and partial occlusion, failure to implant and complications were analyzed with respect to ductal type and size. RESULTS Patient age ranged from 0.1 to 70.1 years (median 3.3 years). Minimum PDA diameter ranged from 2.1 to 6.8 mm (mean 3.0 +/- 0.9 mm). Angiographic types were A-62, B-13, C-6, D-14 and E-9. Using the snare-assisted technique, coil placement was successful in 104/104 patients (100%), irrespective of size or angiographic type. Immediate complete closure was observed in 73/104 (70.2%) and was related to smaller PDA size, but not to angiographic type. Immediate complete closure was type Complete closure was documented in 102/104 (98.1%) at 2- to 16-month follow-up. Successful closure was unrelated to PDA size or type. Coil embolization to the pulmonary artery occurred in 3/104 (2.9%) patients and was not related to PDA size or type. The need far multiple coils was found in 28/104 patients (26.9%), and was related to larger PDA size, but not to angiographic type. CONCLUSIONS The snare-assisted delivery technique allows successful occlusion of moderate to large PDAs up to 6.8 mm, irrespective of angiographic type. This technique permits improved control and accuracy of coil placement, and facilitates delivery of multiple multiple coils. (C) 1999 by the American College of Cardiology.
引用
收藏
页码:1710 / 1718
页数:9
相关论文
共 16 条
[11]   TWO-DIMENSIONAL ECHOCARDIOGRAPHIC AND COLOR FLOW DOPPLER EVALUATION OF DUCTAL OCCLUSION WITH THE RASHKIND PROSTHESIS [J].
MUSEWE, NN ;
BENSON, LN ;
SMALLHORN, JF ;
FREEDOM, RM .
CIRCULATION, 1989, 80 (06) :1706-1710
[12]   TRANSCATHETER PATENT DUCTUS-ARTERIOSUS OCCLUSION - APPLICATION IN THE SMALL CHILD [J].
NYKANEN, DG ;
HAYES, AM ;
BENSON, LN ;
FREEDOM, RM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (07) :1666-1670
[13]  
OTTENKAMP J, 1992, BRIT HEART J, V68, P301
[14]   Evaluation of Gianturco coils for closure of large (>=3.5 mm) patent ductus arteriosus [J].
Owada, CY ;
Teitel, DF ;
Moore, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (07) :1856-1862
[15]   Follow-up of coil occlusion of patent ductus arteriosus [J].
Shim, D ;
Fedderly, RT ;
Beekman, RH ;
Ludomirsky, A ;
Young, ML ;
Schork, MA ;
Lloyd, TR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (01) :207-211
[16]   USE OF PREFORMED NITINOL SNARE TO IMPROVE TRANSCATHETER COIL DELIVERY IN OCCLUSION OF PATENT DUCTUS-ARTERIOSUS [J].
SOMMER, RJ ;
GUTIERREZ, A ;
LAI, WW ;
PARNESS, IA .
AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (08) :836-839