Simultaneous determination of busulphan in plasma samples by liquid chromatography-electrospray ionization mass spectrometry utilizing microextraction in packed syringe (MEPS) as on-line sample preparation method

被引:50
作者
Abdel-Rehim, Mohamed [1 ]
Hassan, Zuzana
Skansem, Patrik
Hassan, Moustapha
机构
[1] AstraZeneca R&D Sodertalje, Dept DMPK & Bioanal, DMPK&BAC, SE-15185 Sodertalje, Sweden
[2] Karlstad Univ, Dept Chem, Karlstad, Sweden
[3] Novum Karolinska Univ Hosp, Clin Res Ctr, Expt Canc Med, Huddine, Sweden
[4] Karolinska Inst, Dept Lab Med, S-10401 Stockholm, Sweden
关键词
Busulfan; MEPS; LC-MS/MS; pharmacokinetics; TDM;
D O I
10.1080/10826070701632337
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Busulphan is an alkylating agent used in high doses as preparative regimen before stem cell transplantation (SCT). Busulphan has a narrow therapeutic window and under- or overdosing may have a fatal outcome for the patient. Therapeutic drug monitoring followed by dose adjustment is currently used to adjust the exposure to busulphan. This is an important issue to optimise and individualise high dose therapy with busulphan. However, this approach is limited to centres with experienced personal measuring busulphan plasma concentrations. An automated and easy-to-handle method for measurement of busulphan plasma concentrations may facilitate and wide-spread drug monitoring approach and thus improve the outcome of the patients undergoing SCT. Microextraction in packed syringe (MEPS) in combination with liquid chromatography and electrospray ionization mass spectrometric detection (LC-MS/LC-MS-MS) to quantify busulphan in human plasma samples without derivatization was developed. MEPS is a new miniaturised, solid-phase extraction technique that can be connected on-line to GC or LC without any modifications. In MEPS approximately 1 mg of the solid packing material is inserted into a syringe (100-250 mu L) as a plug. The validation of the method showed that the selectivity, accuracy and precision for the method were satisfactory. This is well in line with the international criteria for the study validation. The present method has shortened extraction time considerably and the method is fully automated, which benefits therapeutic drug monitoring of busulphan in SCT.
引用
收藏
页码:3029 / 3041
页数:13
相关论文
共 29 条
[1]   Microextraction in packed syringe (MEPS) for liquid and gas chromatographic applications. Part II - Determination of ropivacaine and its metabolites in human plasma samples using MEPS with liquid chromatography/tandem mass spectrometry [J].
Abdel-Rehim, M ;
Altun, Z ;
Blomberg, L .
JOURNAL OF MASS SPECTROMETRY, 2004, 39 (12) :1488-1493
[2]   New trend in sample preparation: on-line microextraction in packed syringe for liquid and gas chromatography applications - I. Determination of local anaesthetics in human plasma samples using gas chromatography-mass spectrometry [J].
Abdel-Rehim, M .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 801 (02) :317-321
[3]   On-line derivatization utilizing solid-phase microextraction (SPME) for determination of busulphan in plasma using gas chromatography-mass spectrometry (GC-MS) [J].
Abdel-Rehim, M ;
Hassan, Z ;
Blomberg, L ;
Hassan, M .
THERAPEUTIC DRUG MONITORING, 2003, 25 (03) :400-406
[4]  
ABDELREHIM M, 2006, LCT RT, V29, P829
[5]   THE SYNDROME OF HEPATIC VENOOCCLUSIVE DISEASE AFTER MARROW TRANSPLANTATION [J].
BEARMAN, SI .
BLOOD, 1995, 85 (11) :3005-3020
[6]   An evaluation of engraftment, toxicity and busulfan concentration in children receiving bone marrow transplantation for leukemia or genetic disease [J].
Bolinger, AM ;
Zangwill, AB ;
Slattery, JT ;
Glidden, D ;
DeSantes, K ;
Heyn, L ;
Risler, LJ ;
Bostrom, B ;
Cowan, MJ .
BONE MARROW TRANSPLANTATION, 2000, 25 (09) :925-930
[7]  
Buggia I, 1996, ANTICANCER RES, V16, P2083
[8]   An improved limited sampling method for individualised busulphan dosing in bone marrow transplantation in children [J].
Chattergoon, DS ;
Saunders, EF ;
Klein, J ;
Calderwood, S ;
Doyle, J ;
Freedman, MH ;
Koren, G .
BONE MARROW TRANSPLANTATION, 1997, 20 (05) :347-354
[9]  
Dix SP, 1996, BONE MARROW TRANSPL, V17, P225
[10]   Fast and sensitive environmental analysis utilizing microextraction in packed syringe online with gas chromatography-mass spectrometry - Determination of polycyclic aromatic hydrocarbons in water [J].
El-Beqqali, Aziza ;
Kussak, Anders ;
Abdel-Rehim, Mohamed .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1114 (02) :234-238