Fast and sensitive environmental analysis utilizing microextraction in packed syringe online with gas chromatography-mass spectrometry - Determination of polycyclic aromatic hydrocarbons in water

被引:106
作者
El-Beqqali, Aziza
Kussak, Anders
Abdel-Rehim, Mohamed [1 ]
机构
[1] AstraZeneca, R&D, DMPK & BAC, SE-15185 Sodertalje, Sweden
[2] Univ Coll S Stockholm, SE-14189 Stockholm, Sweden
[3] Karlstad Univ, Dept Chem, SE-65188 Karlstad, Sweden
关键词
online sample preparation; microextraction in packed syringe; gas chromatography/mass spectrometry; polycyclic aromatic hydrocarbons; validation;
D O I
10.1016/j.chroma.2006.02.024
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new sensitive, selective, fast and accurate technique for online sample preparation was developed. Microextraction in a packed syringe (MEPS) is a new miniaturised, solid-phase extraction (SPE) technique that can be connected online to GC or LC without any modifications. In MEPS approximately 1 mg of the solid packing material is inserted into a syringe (100-250 ml) as a plug. Sample preparation takes place on the packed bed. The bed can be coated to provide selective and suitable sampling conditions. The new method is very promising. It is very easy to use, fully automated, of low cost and rapid in comparison with previously used methods. The determination of polycyclic hydrocarbons (PAHs) in water was performed using MEPS as sample preparation method online with gas chromatography and mass spectrometry (MEPS-GC-MS). The results from MEPS as sample preparation were compared with other techniques such as stir bar sorptive extraction (SBSE) and solid-phase microextraction (SPME). The method was validated and the standard curves were evaluated by the means of quadratic regression and weighted by inverse of the concentration: 1/x for the calibration range 5-1000 ng/L. The MEPS applied polymer (silica-C8) could be used more than 400 times before the syringe was discarded. The extraction recovery was about 70%. The results showed close correlation coefficients (R > 0.998) for all analytes in the calibration range studied. The accuracy of MEPS-GC-MS was between 90 and 113% and the inter-day precision (n = 3 days), expressed as the relative standard deviation (RSD%), was 8-16%. MEPS reduced the handling time by 30 and 100 times compared to SPME and SBSE, respectively. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:234 / 238
页数:5
相关论文
共 14 条
[1]   Microextraction in packed syringe (MEPS) for liquid and gas chromatographic applications. Part II - Determination of ropivacaine and its metabolites in human plasma samples using MEPS with liquid chromatography/tandem mass spectrometry [J].
Abdel-Rehim, M ;
Altun, Z ;
Blomberg, L .
JOURNAL OF MASS SPECTROMETRY, 2004, 39 (12) :1488-1493
[2]   New trend in sample preparation: on-line microextraction in packed syringe for liquid and gas chromatography applications - I. Determination of local anaesthetics in human plasma samples using gas chromatography-mass spectrometry [J].
Abdel-Rehim, M .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 801 (02) :317-321
[3]   New trends in sample preparation: on-line microextraction in packed syringe (MEPS) for LC and GC applications Part III: Determination and validation of local anaesthetics in human plasma samples using a cation-exchange sorbent, and MEPS-LC-MS-MS [J].
Altun, Z ;
Abdel-Rehim, M ;
Blomberg, LG .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2) :129-135
[4]   MultiSimplex optimisation of the solid-phase microextraction-gas chromatographic-mass spectrometric determination of polycyclic aromatic hydrocarbons, polychlorinated biphenyls and phthalates from water samples [J].
Cortazar, E ;
Zuloaga, O ;
Sanz, J ;
Raposo, JC ;
Etxebarria, N ;
Fernández, LA .
JOURNAL OF CHROMATOGRAPHY A, 2002, 978 (1-2) :165-175
[5]  
European Commission, 2002, SCFCSCNTMPAH29 EUR C
[6]   Minimal clean-up and rapid determination of polycyclic aromatic hydrocarbons in instant coffee [J].
García-Falcón, MS ;
Cancho-Grande, B ;
Simal-Gándara, J .
FOOD CHEMISTRY, 2005, 90 (04) :643-647
[9]   Application of stir bar sorptive extraction to the determination of polycyclic aromatic hydrocarbons in aqueous samples [J].
Kolahgar, B ;
Hoffmann, A ;
Heiden, AC .
JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) :225-230
[10]   Concentrations and health risk of polycyclic aromatic hydrocarbons in tea [J].
Lin, DH ;
Tu, YY ;
Zhu, LZ .