3D CT Analysis of Combined Cup and Stem Anteversion in Cases of Cup Navigation in Hip Arthroplasty

被引:16
作者
Wassilew, Georgi I. [1 ]
Perka, Carsten [1 ]
Koenig, Christian [2 ]
Janz, Viktor [1 ]
Asbach, Patrick [3 ]
Hasart, Olaf [1 ]
机构
[1] Charite, Dept Orthoped, Ctr Musculoskeletal Surg, D-10117 Berlin, Germany
[2] Charite, Julius Wolff Inst, D-13353 Berlin, Germany
[3] Charite, Dept Radiol, Charite, D-13353 Berlin, Germany
关键词
ACETABULAR COMPONENT; ORIENTATION; DISLOCATION; ALIGNMENT; ACCURACY; POSITION; MOTION; RANGE; FEMUR; WEAR;
D O I
10.3928/01477447-20100510-53
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Navigation of the cup in total hip arthroplasty is well analyzed and shows accurate results, reducing cup outliers of Lewinnek's "safe zone." With regard to the combined anteversion of cup and stem, however, a "new" safe zone with a range of 25 degrees to 50 degrees has been published. The aim of this study was to analyze total anteversion (cup and stem) by postoperative 3D computed tomography in isolated cup navigation cases. In 46 patients, the mean combined anteversion was 34.4 degrees (range, 16.3 degrees-57.3 degrees, SD +/- 9.3 degrees) with 10 outliers. The mean cup anteversion was 19.5 degrees (range, 11 degrees-27 degrees, SD +/- 3.7 degrees). Regarding Lewinnek's "safe zone" (cup only), we observed 5 outliers. An improvement of technique of stem implantation or navigation may reduce outliers of combined anteversion.
引用
收藏
页码:48 / 51
页数:4
相关论文
共 21 条
[1]
Biedermann R, 2005, J BONE JOINT SURG BR, V87B, P762, DOI 10.1302/0301-620X.87B6
[2]
The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[3]
Effects of acetabular abduction on cup wear rates in total hip arthroplasty [J].
Del Schutte, H ;
Lipman, AJ ;
Bannar, SM ;
Livermore, JT ;
Ilstrup, D ;
Morrey, BF .
JOURNAL OF ARTHROPLASTY, 1998, 13 (06) :621-626
[4]
Comparison of a mechanical acetabular alignment guide with computer placement of the socket [J].
DiGioia, AM ;
Jaramaz, B ;
Plakseychuk, AY ;
Moody, JE ;
Nikou, C ;
LaBarca, RS ;
Levison, TJ ;
Picard, F .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :359-364
[5]
Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position [J].
Dorr, Lawrence A. ;
Malik, Aamer ;
Wan, Zhinian ;
Long, William T. ;
Harris, Michael .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (465) :92-99
[6]
A Comparison of Surgeon Estimation and Computed Tomographic Measurement of Femoral Component Anteversion in Cementless Total Hip Arthroplasty [J].
Dorr, Lawrence D. ;
Wan, Zhinian ;
Malik, Aamer ;
Zhu, Jinjun ;
Dastane, Manish ;
Deshmane, Prashant .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (11) :2598-2604
[7]
Combined Anteversion Technique for Total Hip Arthroplasty [J].
Dorr, Lawrence D. ;
Malik, Aamer ;
Dastane, Manish ;
Wan, Zhinian .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (01) :119-127
[8]
STRUCTURAL AND CELLULAR ASSESSMENT OF BONE QUALITY OF PROXIMAL FEMUR [J].
DORR, LD ;
FAUGERE, MC ;
MACKEL, AM ;
GRUEN, TA ;
BOGNAR, B ;
MALLUCHE, HH .
BONE, 1993, 14 (03) :231-242
[9]
Ultrasound-based Navigation and 3D CT Compared in Acetabular Cup Position [J].
Hasart, Olaf ;
Poepplau, Berry M. ;
Asbach, Patrick ;
Perka, Carsten ;
Wassilew, Georgi I. .
ORTHOPEDICS, 2009, 32 (10) :6-10
[10]
Factors predisposing to dislocation after primary total hip arthroplasty - A multivariate analysis [J].
Jolles, BM ;
Zangger, P ;
Leyvraz, PF .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :282-288