Cardiovascular circulation and hepatic perfusion of pigs in 4-dimensional films evaluated by 256-slice cone-beam computed tomography

被引:18
作者
Funabashi, N
Yoshida, K
Tadokoro, H
Nakagawa, K
Komiyama, N
Odaka, K
Tsunoo, T
Mori, S
Tanada, S
Endo, M
Komuro, I
机构
[1] Chiba Univ, Grad Sch Med, Dept Cardiovasc Sci & Med, Chuo Ku, Chiba 2608670, Japan
[2] Natl Inst Radiol Sci, Chiba, Japan
关键词
4-D perfusion cardiovascular circulation; hepatic perfusion; 256-slice cone beam computed tomography;
D O I
10.1253/circj.69.585
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background In both cardiac and hepatic disorders it is desirable to accurately visualize the direction and scale of blood flow in the whole organ in pulsating 3-dimensional (D) images, which are known as 4-D images. Methods and Results The present study used 256-slice cone-beam computed tomography (CT) (Athena, Sony-Toshiba) at one rotation per second and a section thickness of 0.5 mm to show the dynamics of cardiovascular circulation and hepatic perfusion by contrast injection in 4-D films of pigs. Four pigs (20 kg each) were anesthetized with isoflurane. The distal tips of the catheters were positioned in the inferior vena cava (IVC) (pigs 1-3) and in the proper hepatic artery (pig 4). Volumetric scanning and injection of contrast material were started simultaneously and continued for 25s with image reconstruction at 1-s intervals. In pigs 1-3, 4-D filming revealed the dynamics of cardiovascular circulation, first in the IVC, followed by the right ventricle and pulmonary artery, then the left ventricle, left atrium, pulmonary vein, and finally, the right heart disappeared and only the left heart and aorta remained visible. In pig 4, the hepatic arterial trees, followed by the venous trees, could be easily visualized in turn on the 4-D images. Conclusions This technology successfully demonstrated cardiovascular circulation and hepatic perfusion in 4-D and will have clinical applicability.
引用
收藏
页码:585 / 589
页数:5
相关论文
共 28 条
[1]   ABNORMAL-BLOOD PATHWAYS IN LEFT-VENTRICULAR CAVITY IN ACUTE MYOCARDIAL-INFARCTION - EXPERIMENTAL-OBSERVATIONS WITH SPECIAL REFERENCE TO REGIONAL WALL MOTION ABNORMALITY AND HEMOSTASIS [J].
BEPPU, S ;
IZUMI, S ;
MIYATAKE, K ;
NAGATA, S ;
PARK, YD ;
SAKAKIBARA, H ;
NIMURA, Y .
CIRCULATION, 1988, 78 (01) :157-164
[2]   Early changes in liver perfusion caused by occult metastases in rats:: Detection with quantitative CT [J].
Cuenod, CA ;
Leconte, I ;
Siauve, N ;
Resten, A ;
Dromain, C ;
Poulet, B ;
Frouin, F ;
Clément, O ;
Frija, G .
RADIOLOGY, 2001, 218 (02) :556-561
[3]   Development and performance evaluation of the first model of 4-D CT-scanner [J].
Endo, M ;
Mori, S ;
Tsunoo, T ;
Kandatsu, S ;
Tanada, S ;
Aradate, H ;
Saito, Y ;
Miyazaki, H ;
Satoh, K ;
Matsusita, S ;
Kusakabe, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) :1667-1671
[4]  
Endo Masahiro, 2003, Radiat Med, V21, P17
[5]   Hepatic haemodynamics: interrelationships between contrast enhancement and perfusion on CT and Doppler perfusion indices [J].
Fuentes, MA ;
Keith, CJ ;
Griffiths, M ;
Durbridge, G ;
Miles, KA .
BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (889) :17-23
[6]  
Fujino T, 2003, CIRC J, V67, P757
[7]   Qualitative blood flow differentiation - Depiction of a left to right cardiac shunt across a ventricular septal defect using electron-beam computed tomography [J].
Funabashi, N ;
Rubin, GD .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 2000, 64 (11) :901-903
[8]   Double aortic arch with a compressed trachea demonstrated by multislice computed tomography [J].
Funabashi, N ;
Ishida, A ;
Yoshida, K ;
Komuro, I .
CIRCULATION, 2004, 110 (07) :E68-E69
[9]   New method of measuring coronary diameter by electron-beam computed tomographic angiography using adjusted thresholds determined by calibration with aortic opacity [J].
Funabashi, N ;
Kobayashi, Y ;
Kudo, M ;
Asano, M ;
Teramoto, K ;
Komuro, I ;
Rubin, GD .
CIRCULATION JOURNAL, 2004, 68 (08) :769-777
[10]   Endoluminal perspective volume rendering of coronary arteries using electron-beam computed tomography [J].
Funabashi, N ;
Misumi, K ;
Ohnishi, H ;
Watanabe, M ;
Suzuki, Y ;
Imai, N ;
Yoshida, K ;
Komuro, I .
CIRCULATION JOURNAL, 2003, 67 (12) :1064-1067