Assessment of cardiac output in children: A comparison between the pressure recording analytical method and Doppler echocardiogyaphy

被引:49
作者
Calamandrei, Marco [1 ]
Mirabile, Lorenzo [1 ]
Muschetta, Stefania [1 ]
Gensini, Gian Franco [3 ]
De Simone, Luciano [2 ]
Romano, Salvatore M. [3 ]
机构
[1] Meyer Childrens Hosp, Dept Anesthesia & Intens Care, I-50132 Florence, Italy
[2] Meyer Childrens Hosp, Dept Paediat Cardiol, I-50132 Florence, Italy
[3] Univ Florence, Dept Crit Care, UO Internal Med & Cardiol, I-50121 Florence, Italy
关键词
cardiac output; Doppler echocardiography; arterial pressure; children; hemodynamics; monitoring;
D O I
10.1097/PCC.0b013e31816c7151
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To assess cardiac output in pediatric patients with the pressure recording analytical method (PRAM) and the Doppler echocardiography method. PRAM derives cardiac output from beat-by-beat analysis of the arterial pressure profile (systolic and diastolic phase) in the time domain. Design: A prospective observational study. Setting. Pediatric intensive care, unit at a tertiary care children's hospital.. Patients: Forty-eight patients between the ages of 1 month and 18 yrs. Interventions: Femoral or radial artery catheterization and mechanical ventilation. Measurements and Main Results. Cardiac output was simultaneously estimated by Doppler echocardiography and PRAM. Cardiac output values obtained by Doppler echocardiography (2.7 +/- 1.6 L/min, range 0.92-8.20) were significantly correlated with those estimated by PRAM (2.6 +/- 1.7 L/min, range 0.89-7.48; r(2) = .99, p < .01). The mean difference between the two estimates was 0.12 +/- 0.27 L.min(-1) (95% confidence interval, -0.54 to 0.77 L.min(-1)). Conclusions: In the range of ages evaluated, PRAM provides reliable estimates of cardiac output when compared with noninvasive techniques.
引用
收藏
页码:310 / 312
页数:3
相关论文
共 17 条
[1]   NON-INVASIVE PULSED DOPPLER DETERMINATION OF CARDIAC-OUTPUT IN NEONATES AND CHILDREN [J].
ALVERSON, DC ;
ELDRIDGE, M ;
DILLON, T ;
YABEK, SM ;
BERMAN, W .
JOURNAL OF PEDIATRICS, 1982, 101 (01) :46-50
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Hemodynamic support in fluid-refractory pediatric septic shock [J].
Ceneviva, G ;
Paschall, JA ;
Maffei, F ;
Carcillo, JA .
PEDIATRICS, 1998, 102 (02) :art. no.-e19
[4]   Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature [J].
Chew, MS ;
Poelaert, J .
INTENSIVE CARE MEDICINE, 2003, 29 (11) :1889-1894
[5]   A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[6]   DIRECT BLOOD-PRESSURE MEASUREMENT - DYNAMIC-RESPONSE REQUIREMENTS [J].
GARDNER, RM .
ANESTHESIOLOGY, 1981, 54 (03) :227-236
[7]   Cardiac output monitoring by pressure recording analytical method in cardiac surgery [J].
Giomarelli, P ;
Biagioli, B ;
Scolletta, S .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 26 (03) :515-520
[8]   THE EFFECTS OF SAMPLING SITE ON THE 2-DIMENSIONAL ECHO-DOPPLER DETERMINATION OF CARDIAC-OUTPUT [J].
LABOVITZ, AJ ;
BUCKINGHAM, TA ;
HABERMEHL, K ;
NELSON, J ;
KENNEDY, HL ;
WILLIAMS, GA .
AMERICAN HEART JOURNAL, 1985, 109 (02) :327-332
[9]   CARDIAC-OUTPUT BY PULSED DOPPLER IN NEONATES USING THE APICAL WINDOW [J].
MANDELBAUMISKEN, VH ;
LINDERKAMP, O .
PEDIATRIC CARDIOLOGY, 1991, 12 (01) :13-16
[10]   DOPPLER DETERMINATION OF CARDIAC-OUTPUT IN INFANTS AND CHILDREN - COMPARISON WITH SIMULTANEOUS THERMODILUTION [J].
MELLANDER, M ;
SABEL, KG ;
CAIDAHL, K ;
SOLYMAR, L ;
ERIKSSON, B .
PEDIATRIC CARDIOLOGY, 1987, 8 (04) :241-246