Analysis of patient repositioning accuracy in precision radiation therapy using automated image fusion

被引:23
作者
Robar, James L.
Clark, Brenda G.
Schella, Jason W.
Kim, Chang Seon
机构
[1] Dalhousie Univ, Dept Radiat Oncol, Halifax, NS B3H 1V7, Canada
[2] Dalhousie Univ, Nova Scotia Canc Ctr, Dept Phys Med, Halifax, NS B3H 1V7, Canada
[3] Univ British Columbia, Dept Phys & Astron, Vancouver, BC V5Z 4E6, Canada
[4] British Columbia Canc Agcy, Vancouver Ctr, Vancouver, BC V5Z 4E6, Canada
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2005年 / 6卷 / 01期
关键词
radiation therapy; immobilization; intensity-modulated radiation therapy; stereotactic radiotherapy; stereotactic radiosurgery;
D O I
10.1120/jacmp.2023.25323
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This work describes a rapid and objective method of determining repositioning error during the course of precision radiation therapy using off-line CT imaging and automated mutual-information image fusion. The technique eliminates the variability associated with manual identification of anatomical landmarks by observers. A phantom study was conducted to quantify the accuracy of the image co-registration-based analysis itself. For CT voxel dimensions of 0.65 x 0.65 x 1.0 mm(3), the method is shown to detect translations with an accuracy of 0.5 mm in the anterior-posterior and lateral dimensions and 0.8 mm in the superior-inferior dimension. Phantom rotation in the coronal plane was detected to within 0.5 of expected values. The analysis has been applied to eight radiotherapy patients at two independent clinics, each immobilized by the same system for cranial stereotactic radiotherapy and CT-imaged once per week over the five- to six-week course of treatment. Among all patients, the ranges of translation in the anterior-posterior, lateral, and superior-inferior dimensions were - 0.91 mm to 0.77 mm, - 0.66 mm to 1.02 mm, and - 2.24 mm to 3.47 mm, respectively. Considering all patients and CT scans, the standard deviations of translation were 0.42 mm, 0.47 mm, and 1.36 mm in the anterior-posterior, lateral, and superior-inferior dimensions, respectively. The ranges of patient rotation about the superior-inferior, left-right, and anterior-posterior axes were - 2.84 to 2.62, - 1.74 to 1.96, and - 1.78 to 1.42, respectively.
引用
收藏
页码:71 / 83
页数:13
相关论文
共 20 条
[1]   Patient position reproducibility in fractionated stereotactically guided conformal radiotherapy using the BrainLab® mask system [J].
Alheit, H ;
Dornfeld, S ;
Dawel, M ;
Alheit, M ;
Henzel, B ;
Steckler, K ;
Blank, H ;
Geyer, P .
STRAHLENTHERAPIE UND ONKOLOGIE, 2001, 177 (05) :264-268
[2]   Commissioning a system for stereotactic radiosurgery/radiotherapy of the head and neck [J].
Clark, BG ;
Robar, J ;
Vollans, E ;
Audet, C ;
Sheehan, F .
RADIOSURGERY, VOL 4, 2002, 4 :228-238
[3]   A NONINVASIVE, RELOCATABLE STEREOTAXIC FRAME FOR FRACTIONATED RADIOTHERAPY AND MULTIPLE IMAGING [J].
GRAHAM, JD ;
WARRINGTON, AP ;
GILL, SS ;
BRADA, M .
RADIOTHERAPY AND ONCOLOGY, 1991, 21 (01) :60-62
[4]   Repositioning accuracy of a noninvasive head fixation system for stereotactic radiotherapy [J].
Hamilton, RJ ;
Kuchnir, FT ;
Pelizzari, CA ;
Sweeney, PJ ;
Rubin, SJ .
MEDICAL PHYSICS, 1996, 23 (11) :1909-1917
[5]   Repositioning accuracy with the Laitinen frame for fractionated stereotactic radiation therapy in adult and pediatric brain tumors: Preliminary report [J].
Kalapurakal, JA ;
Ilahi, Z ;
Kepka, AG ;
Bista, T ;
Goldman, S ;
Tomita, T ;
Marymont, MH .
RADIOLOGY, 2001, 218 (01) :157-161
[6]   Noninvasive patient fixation for extracranial stereotactic radiotherapy [J].
Lohr, F ;
Debus, J ;
Frank, C ;
Herfarth, K ;
Pastyr, O ;
Rhein, B ;
Bahner, ML ;
Schlegel, W ;
Wannenmacher, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (02) :521-527
[7]  
Lopatta E, 2003, STRAHLENTHER ONKOL, V179, P571, DOI 10.1007/s00066-003-0941-3
[8]   STEREOTACTIC FRAME FOR NEURORADIOLOGY AND CHARGED-PARTICLE BRAGG PEAK RADIOSURGERY OF INTRACRANIAL DISORDERS [J].
LYMAN, JT ;
PHILLIPS, MH ;
FRANKEL, KA ;
FABRIKANT, JI .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 16 (06) :1615-1621
[9]   HEAVY CHARGED-PARTICLE STEREOTACTIC RADIOSURGERY - CEREBRAL-ANGIOGRAPHY AND CT IN THE TREATMENT OF INTRACRANIAL VASCULAR MALFORMATIONS [J].
PHILLIPS, MH ;
FRANKEL, KA ;
LYMAN, JT ;
FABRIKANT, JI ;
LEVY, RP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (02) :419-426
[10]   Patient position reproducibility in fractionated stereotactic radiotherapy: an update after changing dental impression material [J].
Rosenberg, I ;
Alheit, H ;
Beardmore, C ;
Lee, KS ;
Warrington, AP ;
Brada, M .
RADIOTHERAPY AND ONCOLOGY, 1999, 50 (02) :239-240