A Novel Screening Method for Competitive FRET-Aptamers Applied to E. coli Assay Development

被引:78
作者
Bruno, John G. [1 ]
Carrillo, Maria P. [1 ]
Phillips, Taylor [1 ]
Andrews, Carrie J. [1 ]
机构
[1] Operat Technol Corp, San Antonio, TX 78229 USA
基金
美国国家科学基金会;
关键词
Aptamer; Coliform; High-throughput screening; SELEX; Waterborne; IN-VITRO SELECTION; DNA APTAMERS; SIGNALING APTAMERS; ESCHERICHIA-COLI; METHYLPHOSPHONIC ACID; FLUORESCENCE ASSAY; BEACONS; SPORES;
D O I
10.1007/s10895-010-0670-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel high-throughput screening method is described in which a family of DNA aptamers selected against E. coli outer membrane proteins (OMPs) is subjected to PCR in the presence of fluorophore-dUTP conjugates using Deep VentA (R) exo- polymerase. The fluorophore-doped aptamers and their complementary strands are then heated to render them single-stranded and screened in filter well microtiter plates for fluorescence resonance energy transfer (FRET) assay potential. Using this system, a superior competitive FRET-aptamer designated EcO 4R was identified and the location of its putative binding pocket was determined by individually testing FRET potential in each of the secondary loop structures. By labeling the binding pocket with Alexa Fluor (AF) 647 and binding the aptamer to heavily Black Hole Quencher-3 (BHQ-3)-labeled E. coli bacteria, detection of as few as 30 live unlabeled E. coli per ml was achieved in a competitive displacement FRET assay format. The far red fluorescence emission enables detection in largely blue-green autofluorescent matrices. In addition, the competitive transfer of AF 647-EcO-4R aptamer to unlabeled E. coli cells after a 15 min equilibration period was verified by fluorescence microscopy. The present study also demonstrated that high aptamer affinity is not well correlated with competitive FRET potential.
引用
收藏
页码:1211 / 1223
页数:13
相关论文
共 31 条
[11]   The Vienna RNA Websuite [J].
Gruber, Andreas R. ;
Lorenz, Ronny ;
Bernhart, Stephan H. ;
Neuboeck, Richard ;
Hofacker, Ivo L. .
NUCLEIC ACIDS RESEARCH, 2008, 36 :W70-W74
[12]   Aptamer beacons for the direct detection of proteins [J].
Hamaguchi, N ;
Ellington, A ;
Stanton, M .
ANALYTICAL BIOCHEMISTRY, 2001, 294 (02) :126-131
[13]   Selection of aptamers against live bacterial cells [J].
Hamula, Camille L. A. ;
Zhang, Hongquan ;
Guan, Le Luo ;
Li, Xing-Fang ;
Le, X. Chris .
ANALYTICAL CHEMISTRY, 2008, 80 (20) :7812-7819
[14]   Fluorescence assay based on aptamer-quantum dot binding to Bacillus thuringiensis spores [J].
Ikanovic, Milada ;
Rudzinski, Walter E. ;
Bruno, John G. ;
Allman, Amity ;
Carrillo, Maria P. ;
Dwarakanath, Sulatha ;
Bhahdigadi, Suneetha ;
Rao, Poornima ;
Kiel, Johnathan L. ;
Andrews, Carrie J. .
JOURNAL OF FLUORESCENCE, 2007, 17 (02) :193-199
[15]  
Jayasena SD, 1999, CLIN CHEM, V45, P1628
[16]   In vitro selection of signaling aptamers [J].
Jhaveri, S ;
Rajendran, M ;
Ellington, AD .
NATURE BIOTECHNOLOGY, 2000, 18 (12) :1293-1297
[17]   Selection, characterization, and application of DNA aptamers for the capture and detection of Salmonella enterica serovars [J].
Joshi, Raghavendra ;
Janagama, Harish ;
Dwivedi, Hari P. ;
Kumar, T. M. A. Senthil ;
Jaykus, Lee-Ann ;
Schefers, Jeremy ;
Sreevatsan, Srinand .
MOLECULAR AND CELLULAR PROBES, 2009, 23 (01) :20-28
[18]   Signaling aptamers created using fluorescent nucleotide analogues [J].
Katilius, Evaldas ;
Katiliene, Zivile ;
Woodbury, Neal W. .
ANALYTICAL CHEMISTRY, 2006, 78 (18) :6484-6489
[19]   A sensitive method to detect Escherichia coli based on immunomagnetic separation and real-time PCR amplification of aptamers [J].
Lee, Hye-Jin ;
Kim, Byoung Chan ;
Kim, Kyung-Woo ;
Kim, Young Keun ;
Kim, Jungbae ;
Oh, Min-Kyu .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (12) :3550-3555
[20]   Rapid ultrafiltration concentration and biosensor detection of enterococci from large volumes of Florida recreational water [J].
Leskinen, Stephaney D. ;
Lim, Daniel V. .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2008, 74 (15) :4792-4798